Cargando…

Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression

In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely intera...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Andrew D., Rodriguez, Francisco A., Portnuff, Cory D. F., Goupell, Matthew J., Tollin, Daniel J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5051674/
https://www.ncbi.nlm.nih.gov/pubmed/27698258
http://dx.doi.org/10.1177/2331216516668303
_version_ 1782458122296623104
author Brown, Andrew D.
Rodriguez, Francisco A.
Portnuff, Cory D. F.
Goupell, Matthew J.
Tollin, Daniel J.
author_facet Brown, Andrew D.
Rodriguez, Francisco A.
Portnuff, Cory D. F.
Goupell, Matthew J.
Tollin, Daniel J.
author_sort Brown, Andrew D.
collection PubMed
description In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed.
format Online
Article
Text
id pubmed-5051674
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-50516742016-10-18 Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression Brown, Andrew D. Rodriguez, Francisco A. Portnuff, Cory D. F. Goupell, Matthew J. Tollin, Daniel J. Trends Hear Original Articles In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed. SAGE Publications 2016-10-03 /pmc/articles/PMC5051674/ /pubmed/27698258 http://dx.doi.org/10.1177/2331216516668303 Text en © The Author(s) 2016 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Brown, Andrew D.
Rodriguez, Francisco A.
Portnuff, Cory D. F.
Goupell, Matthew J.
Tollin, Daniel J.
Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title_full Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title_fullStr Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title_full_unstemmed Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title_short Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids: Effects of Nonlinear Frequency Compression
title_sort time-varying distortions of binaural information by bilateral hearing aids: effects of nonlinear frequency compression
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5051674/
https://www.ncbi.nlm.nih.gov/pubmed/27698258
http://dx.doi.org/10.1177/2331216516668303
work_keys_str_mv AT brownandrewd timevaryingdistortionsofbinauralinformationbybilateralhearingaidseffectsofnonlinearfrequencycompression
AT rodriguezfranciscoa timevaryingdistortionsofbinauralinformationbybilateralhearingaidseffectsofnonlinearfrequencycompression
AT portnuffcorydf timevaryingdistortionsofbinauralinformationbybilateralhearingaidseffectsofnonlinearfrequencycompression
AT goupellmatthewj timevaryingdistortionsofbinauralinformationbybilateralhearingaidseffectsofnonlinearfrequencycompression
AT tollindanielj timevaryingdistortionsofbinauralinformationbybilateralhearingaidseffectsofnonlinearfrequencycompression