Cargando…

False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial

OBJECTIVES: To analyse false positives (FPs) in breast cancer screening with tomosynthesis (BT) vs. mammography (DM). METHODS: The Malmö Breast Tomosynthesis Screening Trial (MBTST) is a prospective population-based study comparing one-view BT to DM in screening. This study is based on the first hal...

Descripción completa

Detalles Bibliográficos
Autores principales: Lång, Kristina, Nergården, Matilda, Andersson, Ingvar, Rosso, Aldana, Zackrisson, Sophia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052302/
https://www.ncbi.nlm.nih.gov/pubmed/26943342
http://dx.doi.org/10.1007/s00330-016-4265-y
_version_ 1782458208737034240
author Lång, Kristina
Nergården, Matilda
Andersson, Ingvar
Rosso, Aldana
Zackrisson, Sophia
author_facet Lång, Kristina
Nergården, Matilda
Andersson, Ingvar
Rosso, Aldana
Zackrisson, Sophia
author_sort Lång, Kristina
collection PubMed
description OBJECTIVES: To analyse false positives (FPs) in breast cancer screening with tomosynthesis (BT) vs. mammography (DM). METHODS: The Malmö Breast Tomosynthesis Screening Trial (MBTST) is a prospective population-based study comparing one-view BT to DM in screening. This study is based on the first half of the MBTST population (n = 7,500). Differences in FP recall rate, findings leading to recall, work-up and biopsy rate between cases recalled on BT alone, DM alone and BT+DM were analysed. RESULTS: The FP recall rate was 1.7 % for BT alone (n = 131), 0.9 % for DM alone (n = 69) and 1.1 % for BT + DM (n = 81). The FP recall rate for BT alone was halved after the initial phase of the trial, stabilising at 1.5 %. BT doubled the recall of stellate distortions compared to DM (n = 64 vs. n = 33). There were fewer fibroadenomas and cysts, and the biopsy rate was slightly lower for FP recalled on BT alone compared to DM alone (15.3 % vs. 27.6 %: p = 0.037 and 33.8 % vs. 36.2 %; p = 0.641, respectively). CONCLUSIONS: FPs increased with BT screening mainly due to the recall of stellate distortions. The FP recall rate was still well within the European guidelines and showed evidence of a learning curve. Characterisation of rounded lesions was improved with BT. KEY POINTS: • Tomosynthesis screening gave a higher false-positive recall rate than mammography • There was a decline in the false-positive recall rate for tomosynthesis • The recall due to stellate distortions simulating malignancy was doubled with tomosynthesis • Tomosynthesis found more radial and postoperative scar tissue than mammography • Tomosynthesis is better at characterising rounded lesions
format Online
Article
Text
id pubmed-5052302
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-50523022016-10-20 False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial Lång, Kristina Nergården, Matilda Andersson, Ingvar Rosso, Aldana Zackrisson, Sophia Eur Radiol Breast OBJECTIVES: To analyse false positives (FPs) in breast cancer screening with tomosynthesis (BT) vs. mammography (DM). METHODS: The Malmö Breast Tomosynthesis Screening Trial (MBTST) is a prospective population-based study comparing one-view BT to DM in screening. This study is based on the first half of the MBTST population (n = 7,500). Differences in FP recall rate, findings leading to recall, work-up and biopsy rate between cases recalled on BT alone, DM alone and BT+DM were analysed. RESULTS: The FP recall rate was 1.7 % for BT alone (n = 131), 0.9 % for DM alone (n = 69) and 1.1 % for BT + DM (n = 81). The FP recall rate for BT alone was halved after the initial phase of the trial, stabilising at 1.5 %. BT doubled the recall of stellate distortions compared to DM (n = 64 vs. n = 33). There were fewer fibroadenomas and cysts, and the biopsy rate was slightly lower for FP recalled on BT alone compared to DM alone (15.3 % vs. 27.6 %: p = 0.037 and 33.8 % vs. 36.2 %; p = 0.641, respectively). CONCLUSIONS: FPs increased with BT screening mainly due to the recall of stellate distortions. The FP recall rate was still well within the European guidelines and showed evidence of a learning curve. Characterisation of rounded lesions was improved with BT. KEY POINTS: • Tomosynthesis screening gave a higher false-positive recall rate than mammography • There was a decline in the false-positive recall rate for tomosynthesis • The recall due to stellate distortions simulating malignancy was doubled with tomosynthesis • Tomosynthesis found more radial and postoperative scar tissue than mammography • Tomosynthesis is better at characterising rounded lesions Springer Berlin Heidelberg 2016-03-04 2016 /pmc/articles/PMC5052302/ /pubmed/26943342 http://dx.doi.org/10.1007/s00330-016-4265-y Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Breast
Lång, Kristina
Nergården, Matilda
Andersson, Ingvar
Rosso, Aldana
Zackrisson, Sophia
False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title_full False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title_fullStr False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title_full_unstemmed False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title_short False positives in breast cancer screening with one-view breast tomosynthesis: An analysis of findings leading to recall, work-up and biopsy rates in the Malmö Breast Tomosynthesis Screening Trial
title_sort false positives in breast cancer screening with one-view breast tomosynthesis: an analysis of findings leading to recall, work-up and biopsy rates in the malmö breast tomosynthesis screening trial
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052302/
https://www.ncbi.nlm.nih.gov/pubmed/26943342
http://dx.doi.org/10.1007/s00330-016-4265-y
work_keys_str_mv AT langkristina falsepositivesinbreastcancerscreeningwithoneviewbreasttomosynthesisananalysisoffindingsleadingtorecallworkupandbiopsyratesinthemalmobreasttomosynthesisscreeningtrial
AT nergardenmatilda falsepositivesinbreastcancerscreeningwithoneviewbreasttomosynthesisananalysisoffindingsleadingtorecallworkupandbiopsyratesinthemalmobreasttomosynthesisscreeningtrial
AT anderssoningvar falsepositivesinbreastcancerscreeningwithoneviewbreasttomosynthesisananalysisoffindingsleadingtorecallworkupandbiopsyratesinthemalmobreasttomosynthesisscreeningtrial
AT rossoaldana falsepositivesinbreastcancerscreeningwithoneviewbreasttomosynthesisananalysisoffindingsleadingtorecallworkupandbiopsyratesinthemalmobreasttomosynthesisscreeningtrial
AT zackrissonsophia falsepositivesinbreastcancerscreeningwithoneviewbreasttomosynthesisananalysisoffindingsleadingtorecallworkupandbiopsyratesinthemalmobreasttomosynthesisscreeningtrial