Cargando…

Factors affecting the accuracy of chest compression depth estimation

OBJECTIVE: We aimed to estimate the accuracy of visual estimation of chest compression depth and identify potential factors affecting accuracy. METHODS: This simulation study used a basic life support mannequin, the Ambu man. We recorded chest compression with 7 different depths from 1 to 7 cm. Each...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Jung Hee, Cha, Won Chul, Chae, Minjung Kathy, Park, Hang A, Hwang, Sung Yeon, Jin, Sang Chan, Lee, Tae Rim, Shin, Tae Gun, Sim, Min Seob, Jo, Ik Joon, Song, Keun Jeong, Rhee, Joong Eui, Jeong, Yeon Kwon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Emergency Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052833/
https://www.ncbi.nlm.nih.gov/pubmed/27752560
http://dx.doi.org/10.15441/ceem.14.006
_version_ 1782458296128503808
author Kang, Jung Hee
Cha, Won Chul
Chae, Minjung Kathy
Park, Hang A
Hwang, Sung Yeon
Jin, Sang Chan
Lee, Tae Rim
Shin, Tae Gun
Sim, Min Seob
Jo, Ik Joon
Song, Keun Jeong
Rhee, Joong Eui
Jeong, Yeon Kwon
author_facet Kang, Jung Hee
Cha, Won Chul
Chae, Minjung Kathy
Park, Hang A
Hwang, Sung Yeon
Jin, Sang Chan
Lee, Tae Rim
Shin, Tae Gun
Sim, Min Seob
Jo, Ik Joon
Song, Keun Jeong
Rhee, Joong Eui
Jeong, Yeon Kwon
author_sort Kang, Jung Hee
collection PubMed
description OBJECTIVE: We aimed to estimate the accuracy of visual estimation of chest compression depth and identify potential factors affecting accuracy. METHODS: This simulation study used a basic life support mannequin, the Ambu man. We recorded chest compression with 7 different depths from 1 to 7 cm. Each video clip was recorded for a cycle of compression. Three different viewpoints were used to record the video. After filming, 25 clips were randomly selected. Health care providers in an emergency department were asked to estimate the depth of compressions while watching the selected video clips. Examiner determinants such as experience and cardiopulmonary resuscitation training and environment determinants such as the location of the camera (examiner) were collected and analyzed. An estimated depth was considered correct if it was consistent with the one recorded. A multivariate analysis predicting the accuracy of compression depth estimation was performed. RESULTS: Overall, 103 subjects were enrolled in the study; 42 (40.8%) were physicians, 56 (54.4%) nurses, and 5 (4.8%) emergency medical technicians. The mean accuracy was 0.89 (standard deviation, 0.76). Among examiner determinants, only subjects’ occupation and clinical experience showed significant association with outcome (P=0.03 and P=0.08, respectively). All environmental determinants showed significant association with the outcome (all P<0.001). Multivariate analysis showed that accuracy rate was significantly associated with occupation, camera position, and compression depth. CONCLUSIONS: The accuracy rate of chest compression depth estimation was 0.89 and was significantly related with examiner’s occupation, camera view position, and compression depth.
format Online
Article
Text
id pubmed-5052833
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-50528332016-10-17 Factors affecting the accuracy of chest compression depth estimation Kang, Jung Hee Cha, Won Chul Chae, Minjung Kathy Park, Hang A Hwang, Sung Yeon Jin, Sang Chan Lee, Tae Rim Shin, Tae Gun Sim, Min Seob Jo, Ik Joon Song, Keun Jeong Rhee, Joong Eui Jeong, Yeon Kwon Clin Exp Emerg Med Original Article OBJECTIVE: We aimed to estimate the accuracy of visual estimation of chest compression depth and identify potential factors affecting accuracy. METHODS: This simulation study used a basic life support mannequin, the Ambu man. We recorded chest compression with 7 different depths from 1 to 7 cm. Each video clip was recorded for a cycle of compression. Three different viewpoints were used to record the video. After filming, 25 clips were randomly selected. Health care providers in an emergency department were asked to estimate the depth of compressions while watching the selected video clips. Examiner determinants such as experience and cardiopulmonary resuscitation training and environment determinants such as the location of the camera (examiner) were collected and analyzed. An estimated depth was considered correct if it was consistent with the one recorded. A multivariate analysis predicting the accuracy of compression depth estimation was performed. RESULTS: Overall, 103 subjects were enrolled in the study; 42 (40.8%) were physicians, 56 (54.4%) nurses, and 5 (4.8%) emergency medical technicians. The mean accuracy was 0.89 (standard deviation, 0.76). Among examiner determinants, only subjects’ occupation and clinical experience showed significant association with outcome (P=0.03 and P=0.08, respectively). All environmental determinants showed significant association with the outcome (all P<0.001). Multivariate analysis showed that accuracy rate was significantly associated with occupation, camera position, and compression depth. CONCLUSIONS: The accuracy rate of chest compression depth estimation was 0.89 and was significantly related with examiner’s occupation, camera view position, and compression depth. The Korean Society of Emergency Medicine 2014-12-31 /pmc/articles/PMC5052833/ /pubmed/27752560 http://dx.doi.org/10.15441/ceem.14.006 Text en Copyright © 2014 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Original Article
Kang, Jung Hee
Cha, Won Chul
Chae, Minjung Kathy
Park, Hang A
Hwang, Sung Yeon
Jin, Sang Chan
Lee, Tae Rim
Shin, Tae Gun
Sim, Min Seob
Jo, Ik Joon
Song, Keun Jeong
Rhee, Joong Eui
Jeong, Yeon Kwon
Factors affecting the accuracy of chest compression depth estimation
title Factors affecting the accuracy of chest compression depth estimation
title_full Factors affecting the accuracy of chest compression depth estimation
title_fullStr Factors affecting the accuracy of chest compression depth estimation
title_full_unstemmed Factors affecting the accuracy of chest compression depth estimation
title_short Factors affecting the accuracy of chest compression depth estimation
title_sort factors affecting the accuracy of chest compression depth estimation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052833/
https://www.ncbi.nlm.nih.gov/pubmed/27752560
http://dx.doi.org/10.15441/ceem.14.006
work_keys_str_mv AT kangjunghee factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT chawonchul factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT chaeminjungkathy factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT parkhanga factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT hwangsungyeon factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT jinsangchan factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT leetaerim factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT shintaegun factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT simminseob factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT joikjoon factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT songkeunjeong factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT rheejoongeui factorsaffectingtheaccuracyofchestcompressiondepthestimation
AT jeongyeonkwon factorsaffectingtheaccuracyofchestcompressiondepthestimation