Cargando…

Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial

OBJECTIVE: To investigate the time to tracheal intubation using Glidescope videolaryngoscopy (GVL) compared to that of standard laryngoscopy, by using a Macintosh blade (SLM) in a human patient simulator in supine and elevated (ramped) positions. METHODS: In this randomized crossover design, novice...

Descripción completa

Detalles Bibliográficos
Autores principales: Wai, Abraham K. C., Graham, Colin A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Emergency Medicine 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052847/
https://www.ncbi.nlm.nih.gov/pubmed/27752593
http://dx.doi.org/10.15441/ceem.15.048
_version_ 1782458299566784512
author Wai, Abraham K. C.
Graham, Colin A.
author_facet Wai, Abraham K. C.
Graham, Colin A.
author_sort Wai, Abraham K. C.
collection PubMed
description OBJECTIVE: To investigate the time to tracheal intubation using Glidescope videolaryngoscopy (GVL) compared to that of standard laryngoscopy, by using a Macintosh blade (SLM) in a human patient simulator in supine and elevated (ramped) positions. METHODS: In this randomized crossover design, novice intubators (first-year medical students), using both laryngoscopic techniques, attempted tracheal intubation on a human patient simulator with a “normal airway” anatomy (Cormack-Lehane grade I). The simulator was placed in both supine and ramped positions using a commercial mattress system. The mean time to intubation and complications were compared between GVL and SLM in both positions. The percentage of glottic opening (POGO, GVL only) was estimated during intubation in the ramped and supine positions. The primary outcome was time to intubation, and the secondary outcomes included complication rates such as esophageal intubation and dental trauma. RESULTS: There was no difference in the mean time to intubation in either position (P=0.33). The SLM intubation was significantly faster than GVL (mean difference, 1.5 minutes; P<0.001). The mean POGO score for GVL improved by 8% in the ramped position compared to that in supine position (P=0.018). The esophageal intubation rate for SLM was 15% to 17% compared to 1.3% for GVL; dental trauma occurred in 53% to 56% of GVL, compared to 2% to 6% for SLM (P<0.001, respectively). CONCLUSION: Novices had shorter intubation times using standard laryngoscopy with a SLM compared to GVL in both supine and ramped positions. GVL resulted in fewer esophageal intubations, but more dental trauma than standard laryngoscopy.
format Online
Article
Text
id pubmed-5052847
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-50528472016-10-17 Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial Wai, Abraham K. C. Graham, Colin A. Clin Exp Emerg Med Original Article OBJECTIVE: To investigate the time to tracheal intubation using Glidescope videolaryngoscopy (GVL) compared to that of standard laryngoscopy, by using a Macintosh blade (SLM) in a human patient simulator in supine and elevated (ramped) positions. METHODS: In this randomized crossover design, novice intubators (first-year medical students), using both laryngoscopic techniques, attempted tracheal intubation on a human patient simulator with a “normal airway” anatomy (Cormack-Lehane grade I). The simulator was placed in both supine and ramped positions using a commercial mattress system. The mean time to intubation and complications were compared between GVL and SLM in both positions. The percentage of glottic opening (POGO, GVL only) was estimated during intubation in the ramped and supine positions. The primary outcome was time to intubation, and the secondary outcomes included complication rates such as esophageal intubation and dental trauma. RESULTS: There was no difference in the mean time to intubation in either position (P=0.33). The SLM intubation was significantly faster than GVL (mean difference, 1.5 minutes; P<0.001). The mean POGO score for GVL improved by 8% in the ramped position compared to that in supine position (P=0.018). The esophageal intubation rate for SLM was 15% to 17% compared to 1.3% for GVL; dental trauma occurred in 53% to 56% of GVL, compared to 2% to 6% for SLM (P<0.001, respectively). CONCLUSION: Novices had shorter intubation times using standard laryngoscopy with a SLM compared to GVL in both supine and ramped positions. GVL resulted in fewer esophageal intubations, but more dental trauma than standard laryngoscopy. The Korean Society of Emergency Medicine 2015-09-30 /pmc/articles/PMC5052847/ /pubmed/27752593 http://dx.doi.org/10.15441/ceem.15.048 Text en Copyright © 2015 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Original Article
Wai, Abraham K. C.
Graham, Colin A.
Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title_full Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title_fullStr Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title_full_unstemmed Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title_short Effects of an elevated position on time to tracheal intubation by novice intubators using Macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
title_sort effects of an elevated position on time to tracheal intubation by novice intubators using macintosh laryngoscopy or videolaryngoscopy: randomized crossover trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052847/
https://www.ncbi.nlm.nih.gov/pubmed/27752593
http://dx.doi.org/10.15441/ceem.15.048
work_keys_str_mv AT waiabrahamkc effectsofanelevatedpositionontimetotrachealintubationbynoviceintubatorsusingmacintoshlaryngoscopyorvideolaryngoscopyrandomizedcrossovertrial
AT grahamcolina effectsofanelevatedpositionontimetotrachealintubationbynoviceintubatorsusingmacintoshlaryngoscopyorvideolaryngoscopyrandomizedcrossovertrial