Cargando…

Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization. METHODS: A prospective randomized trial was conducted on subjects receiving the standard taping method (group S) compared to a compressive...

Descripción completa

Detalles Bibliográficos
Autores principales: Yun, Kiho, Jeon, Woochan, Kang, Bora, Kim, Giwoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Emergency Medicine 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052858/
https://www.ncbi.nlm.nih.gov/pubmed/27752580
http://dx.doi.org/10.15441/ceem.14.018
_version_ 1782458302166204416
author Yun, Kiho
Jeon, Woochan
Kang, Bora
Kim, Giwoon
author_facet Yun, Kiho
Jeon, Woochan
Kang, Bora
Kim, Giwoon
author_sort Yun, Kiho
collection PubMed
description OBJECTIVE: The purpose of this study was to evaluate the effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization. METHODS: A prospective randomized trial was conducted on subjects receiving the standard taping method (group S) compared to a compressive device method (group C) after removal of the cannula in radial artery catheterization. Primary outcomes were the success rate of hemostasis and complication rate after cannula removal. Secondary outcomes were the cost of compression and the level of convenience. RESULTS: A total of 250 subjects were enrolled in this study. Hemostasis after removal was successful in 122 of 125 (97.6%) subjects in group S and 116 of 125 (92.8%) subjects in group C (P=0.18). Complication rates in group S and group C were 55.2% (69/125) and 48% (60/125), respectively (P=0.35). The cost of compression for group C (approximately 6,740 Korean won) was approximately two times cheaper than for group S (approximately 14,140 Korean won). The level of convenience was significantly higher in group C than in group S (7.4±2.1 vs. 3.7±1.9, p < 0.001). CONCLUSION: These findings suggest that hemostasis using a compressive device may be a suitable alternative method to the standard taping method in controlling hemorrhage following radial artery cannulation.
format Online
Article
Text
id pubmed-5052858
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-50528582016-10-17 Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization Yun, Kiho Jeon, Woochan Kang, Bora Kim, Giwoon Clin Exp Emerg Med Original Article OBJECTIVE: The purpose of this study was to evaluate the effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization. METHODS: A prospective randomized trial was conducted on subjects receiving the standard taping method (group S) compared to a compressive device method (group C) after removal of the cannula in radial artery catheterization. Primary outcomes were the success rate of hemostasis and complication rate after cannula removal. Secondary outcomes were the cost of compression and the level of convenience. RESULTS: A total of 250 subjects were enrolled in this study. Hemostasis after removal was successful in 122 of 125 (97.6%) subjects in group S and 116 of 125 (92.8%) subjects in group C (P=0.18). Complication rates in group S and group C were 55.2% (69/125) and 48% (60/125), respectively (P=0.35). The cost of compression for group C (approximately 6,740 Korean won) was approximately two times cheaper than for group S (approximately 14,140 Korean won). The level of convenience was significantly higher in group C than in group S (7.4±2.1 vs. 3.7±1.9, p < 0.001). CONCLUSION: These findings suggest that hemostasis using a compressive device may be a suitable alternative method to the standard taping method in controlling hemorrhage following radial artery cannulation. The Korean Society of Emergency Medicine 2015-06-30 /pmc/articles/PMC5052858/ /pubmed/27752580 http://dx.doi.org/10.15441/ceem.14.018 Text en © 2015 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yun, Kiho
Jeon, Woochan
Kang, Bora
Kim, Giwoon
Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title_full Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title_fullStr Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title_full_unstemmed Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title_short Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
title_sort effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5052858/
https://www.ncbi.nlm.nih.gov/pubmed/27752580
http://dx.doi.org/10.15441/ceem.14.018
work_keys_str_mv AT yunkiho effectivenessofacompressivedeviceincontrollinghemorrhagefollowingradialarterycatheterization
AT jeonwoochan effectivenessofacompressivedeviceincontrollinghemorrhagefollowingradialarterycatheterization
AT kangbora effectivenessofacompressivedeviceincontrollinghemorrhagefollowingradialarterycatheterization
AT kimgiwoon effectivenessofacompressivedeviceincontrollinghemorrhagefollowingradialarterycatheterization