Cargando…
Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit
BACKGROUND: Second-generation thyroglobulin immunometric assays (Tg-IMAs) have been developed with improved sensitivity. Our aim was to compare the diagnostic value of Tg-IMA measurements using a Kryptor (BRAHMS AG) kit (Tg-K) and an ACCESS (Beckman Coulter) kit (Tg-A) with that of the first-generat...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Endocrine Society
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5053060/ https://www.ncbi.nlm.nih.gov/pubmed/27491718 http://dx.doi.org/10.3803/EnM.2016.31.3.462 |
_version_ | 1782458342649626624 |
---|---|
author | Kim, Mijin Jeon, Min Ji Kim, Won Gu Lee, Jong Jin Ryu, Jin-Sook Cho, Eun-Jung Ko, Dae-Hyun Lee, Woochang Chun, Sail Min, Won-Ki Kim, Tae Yong Shong, Young Kee Kim, Won Bae |
author_facet | Kim, Mijin Jeon, Min Ji Kim, Won Gu Lee, Jong Jin Ryu, Jin-Sook Cho, Eun-Jung Ko, Dae-Hyun Lee, Woochang Chun, Sail Min, Won-Ki Kim, Tae Yong Shong, Young Kee Kim, Won Bae |
author_sort | Kim, Mijin |
collection | PubMed |
description | BACKGROUND: Second-generation thyroglobulin immunometric assays (Tg-IMAs) have been developed with improved sensitivity. Our aim was to compare the diagnostic value of Tg-IMA measurements using a Kryptor (BRAHMS AG) kit (Tg-K) and an ACCESS (Beckman Coulter) kit (Tg-A) with that of the first-generation Tg measurement using a Tg-plus (BRAHMS AG) kit (Tg+). METHODS: We enrolled 82 differentiated thyroid cancer patients who underwent total thyroidectomy with radioactive iodine remnant ablation and who underwent diagnostic whole body scan using recombinant human thyroid stimulating hormone (rhTSH). The Tg+, Tg-K, and Tg-A were measured before rhTSH administration during levothyroxine treatment (suppressed Tg) from the same sample. Serum Tg+ was measured after rhTSH stimulation (stimulated Tg). RESULTS: Suppressed Tg+ was more significantly correlated with suppressed Tg-K (R(2)=0.919, P<0.001) than with suppressed Tg-A (R(2)=0.536, P<0.001). The optimal cut-off values of suppressed Tg+, Tg-K, and Tg-A for predicting stimulated Tg+ of 1 ng/mL were 0.3, 0.2, and 0.2 ng/mL, respectively. The sensitivity, specificity, and accuracy of suppressed Tg+ were 67%, 100%, and 90%, respectively; those of suppressed Tg-K were 83%, 90%, and 88%; those of suppressed Tg-A were 96%, 82%, and 87%, respectively. The positive predictive and negative predictive values of Tg+ were 100% and 87%, respectively; those of Tg-K were 79% and 92%; and those of Tg-A were 73% and 98%. CONCLUSION: We could not clearly demonstrate which kit had better diagnostic performance after comparison of first-generation Tg measurements with Tg-IMA measurements. Also, there were kit-to-kit variations between Tg-IMA kits. Suppressed Tg measured by Tg-IMA was insufficient to completely substitute for a stimulated Tg measurement. |
format | Online Article Text |
id | pubmed-5053060 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Endocrine Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-50530602016-10-07 Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit Kim, Mijin Jeon, Min Ji Kim, Won Gu Lee, Jong Jin Ryu, Jin-Sook Cho, Eun-Jung Ko, Dae-Hyun Lee, Woochang Chun, Sail Min, Won-Ki Kim, Tae Yong Shong, Young Kee Kim, Won Bae Endocrinol Metab (Seoul) Original Article BACKGROUND: Second-generation thyroglobulin immunometric assays (Tg-IMAs) have been developed with improved sensitivity. Our aim was to compare the diagnostic value of Tg-IMA measurements using a Kryptor (BRAHMS AG) kit (Tg-K) and an ACCESS (Beckman Coulter) kit (Tg-A) with that of the first-generation Tg measurement using a Tg-plus (BRAHMS AG) kit (Tg+). METHODS: We enrolled 82 differentiated thyroid cancer patients who underwent total thyroidectomy with radioactive iodine remnant ablation and who underwent diagnostic whole body scan using recombinant human thyroid stimulating hormone (rhTSH). The Tg+, Tg-K, and Tg-A were measured before rhTSH administration during levothyroxine treatment (suppressed Tg) from the same sample. Serum Tg+ was measured after rhTSH stimulation (stimulated Tg). RESULTS: Suppressed Tg+ was more significantly correlated with suppressed Tg-K (R(2)=0.919, P<0.001) than with suppressed Tg-A (R(2)=0.536, P<0.001). The optimal cut-off values of suppressed Tg+, Tg-K, and Tg-A for predicting stimulated Tg+ of 1 ng/mL were 0.3, 0.2, and 0.2 ng/mL, respectively. The sensitivity, specificity, and accuracy of suppressed Tg+ were 67%, 100%, and 90%, respectively; those of suppressed Tg-K were 83%, 90%, and 88%; those of suppressed Tg-A were 96%, 82%, and 87%, respectively. The positive predictive and negative predictive values of Tg+ were 100% and 87%, respectively; those of Tg-K were 79% and 92%; and those of Tg-A were 73% and 98%. CONCLUSION: We could not clearly demonstrate which kit had better diagnostic performance after comparison of first-generation Tg measurements with Tg-IMA measurements. Also, there were kit-to-kit variations between Tg-IMA kits. Suppressed Tg measured by Tg-IMA was insufficient to completely substitute for a stimulated Tg measurement. Korean Endocrine Society 2016-09 2016-08-02 /pmc/articles/PMC5053060/ /pubmed/27491718 http://dx.doi.org/10.3803/EnM.2016.31.3.462 Text en Copyright © 2016 Korean Endocrine Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Mijin Jeon, Min Ji Kim, Won Gu Lee, Jong Jin Ryu, Jin-Sook Cho, Eun-Jung Ko, Dae-Hyun Lee, Woochang Chun, Sail Min, Won-Ki Kim, Tae Yong Shong, Young Kee Kim, Won Bae Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title | Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title_full | Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title_fullStr | Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title_full_unstemmed | Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title_short | Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit |
title_sort | comparison of thyroglobulin measurements using three different immunoassay kits: a bramhs tg-plus ria kit, a bramhs htg sensitive kryptor kit, and a beckman coulter access immunoassay kit |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5053060/ https://www.ncbi.nlm.nih.gov/pubmed/27491718 http://dx.doi.org/10.3803/EnM.2016.31.3.462 |
work_keys_str_mv | AT kimmijin comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT jeonminji comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT kimwongu comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT leejongjin comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT ryujinsook comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT choeunjung comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT kodaehyun comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT leewoochang comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT chunsail comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT minwonki comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT kimtaeyong comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT shongyoungkee comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit AT kimwonbae comparisonofthyroglobulinmeasurementsusingthreedifferentimmunoassaykitsabramhstgplusriakitabramhshtgsensitivekryptorkitandabeckmancoulteraccessimmunoassaykit |