Cargando…
Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures
At ultralow temperatures, longitudinal nuclear magnetic relaxation times become exceedingly long and spectral lines are very broad. These facts pose particular challenges for the measurement of NMR spectra and spin relaxation phenomena. Nuclear spin noise spectroscopy is used to monitor proton spin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5053266/ https://www.ncbi.nlm.nih.gov/pubmed/27305629 http://dx.doi.org/10.1002/cphc.201600323 |
_version_ | 1782458381200523264 |
---|---|
author | Pöschko, Maria Theresia Peat, David Owers‐Bradley, John Müller, Norbert |
author_facet | Pöschko, Maria Theresia Peat, David Owers‐Bradley, John Müller, Norbert |
author_sort | Pöschko, Maria Theresia |
collection | PubMed |
description | At ultralow temperatures, longitudinal nuclear magnetic relaxation times become exceedingly long and spectral lines are very broad. These facts pose particular challenges for the measurement of NMR spectra and spin relaxation phenomena. Nuclear spin noise spectroscopy is used to monitor proton spin polarization buildup to thermal equilibrium of a mixture of glycerol, water, and copper oxide nanoparticles at 17.5 mK in a static magnetic field of 2.5 T. Relaxation times determined in such a way are essentially free from perturbations caused by excitation radiofrequency pulses, radiation damping, and insufficient excitation bandwidth. The experimental spin‐lattice relaxation times determined on resonance by saturation recovery with spin noise detection are consistently longer than those determined by using pulse excitation. These longer values are in better accordance with the expected field dependence trend than those obtained by on‐resonance experiments with pulsed excitation. |
format | Online Article Text |
id | pubmed-5053266 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-50532662016-10-19 Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures Pöschko, Maria Theresia Peat, David Owers‐Bradley, John Müller, Norbert Chemphyschem Articles At ultralow temperatures, longitudinal nuclear magnetic relaxation times become exceedingly long and spectral lines are very broad. These facts pose particular challenges for the measurement of NMR spectra and spin relaxation phenomena. Nuclear spin noise spectroscopy is used to monitor proton spin polarization buildup to thermal equilibrium of a mixture of glycerol, water, and copper oxide nanoparticles at 17.5 mK in a static magnetic field of 2.5 T. Relaxation times determined in such a way are essentially free from perturbations caused by excitation radiofrequency pulses, radiation damping, and insufficient excitation bandwidth. The experimental spin‐lattice relaxation times determined on resonance by saturation recovery with spin noise detection are consistently longer than those determined by using pulse excitation. These longer values are in better accordance with the expected field dependence trend than those obtained by on‐resonance experiments with pulsed excitation. John Wiley and Sons Inc. 2016-07-22 2016-10-05 /pmc/articles/PMC5053266/ /pubmed/27305629 http://dx.doi.org/10.1002/cphc.201600323 Text en © 2016 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Articles Pöschko, Maria Theresia Peat, David Owers‐Bradley, John Müller, Norbert Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title | Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title_full | Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title_fullStr | Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title_full_unstemmed | Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title_short | Use of Nuclear Spin Noise Spectroscopy to Monitor Slow Magnetization Buildup at Millikelvin Temperatures |
title_sort | use of nuclear spin noise spectroscopy to monitor slow magnetization buildup at millikelvin temperatures |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5053266/ https://www.ncbi.nlm.nih.gov/pubmed/27305629 http://dx.doi.org/10.1002/cphc.201600323 |
work_keys_str_mv | AT poschkomariatheresia useofnuclearspinnoisespectroscopytomonitorslowmagnetizationbuildupatmillikelvintemperatures AT peatdavid useofnuclearspinnoisespectroscopytomonitorslowmagnetizationbuildupatmillikelvintemperatures AT owersbradleyjohn useofnuclearspinnoisespectroscopytomonitorslowmagnetizationbuildupatmillikelvintemperatures AT mullernorbert useofnuclearspinnoisespectroscopytomonitorslowmagnetizationbuildupatmillikelvintemperatures |