Cargando…
Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy
BACKGROUND: Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054248/ https://www.ncbi.nlm.nih.gov/pubmed/27722127 http://dx.doi.org/10.5045/br.2016.51.3.171 |
_version_ | 1782458559094587392 |
---|---|
author | Byun, Jung-Hyun Jang, In-Seok Kim, Jong Woo Koh, Eun-Ha |
author_facet | Byun, Jung-Hyun Jang, In-Seok Kim, Jong Woo Koh, Eun-Ha |
author_sort | Byun, Jung-Hyun |
collection | PubMed |
description | BACKGROUND: Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UFH administration, and used appropriate monitoring to determine if an adequate dose of UFH was applied. METHODS: A total of 134 ex vivo samples were obtained from 71 patients with a variety of thromboembolisms. All patients received intravenous UFH therapy and were enrolled from June to September 2015 at Gyeongsang National University Hospital. All laboratory protocols were in accordance with the Clinical and Laboratory Standards Institute guidelines and the College of American Pathologist requirements for aPTT HTR. RESULTS: An aPTT range of 87.1 sec to 128.7 sec corresponded to anti-Xa levels of 0.3 IU/mL to 0.7 IU/mL for HTR under our laboratory conditions. Based on their anti-Xa levels, blood specimen distribution were as follows: less than 0.3 IU/mL, 65.7%; 0.3–0.7 IU/mL (therapeutic range), 33.6%; and more than 0.7 IU/mL, 0.7%. No evidence of recurring thromboembolism was observed. CONCLUSION: Using the conventional aPTT target range may lead to inappropriate dosing of UFH. Transitioning from the aPTT test to the anti-Xa assay is required to avoid the laborious validation of the aPTT HTR test, even though the anti-Xa assay is more expensive. |
format | Online Article Text |
id | pubmed-5054248 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis |
record_format | MEDLINE/PubMed |
spelling | pubmed-50542482016-10-07 Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy Byun, Jung-Hyun Jang, In-Seok Kim, Jong Woo Koh, Eun-Ha Blood Res Original Article BACKGROUND: Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UFH administration, and used appropriate monitoring to determine if an adequate dose of UFH was applied. METHODS: A total of 134 ex vivo samples were obtained from 71 patients with a variety of thromboembolisms. All patients received intravenous UFH therapy and were enrolled from June to September 2015 at Gyeongsang National University Hospital. All laboratory protocols were in accordance with the Clinical and Laboratory Standards Institute guidelines and the College of American Pathologist requirements for aPTT HTR. RESULTS: An aPTT range of 87.1 sec to 128.7 sec corresponded to anti-Xa levels of 0.3 IU/mL to 0.7 IU/mL for HTR under our laboratory conditions. Based on their anti-Xa levels, blood specimen distribution were as follows: less than 0.3 IU/mL, 65.7%; 0.3–0.7 IU/mL (therapeutic range), 33.6%; and more than 0.7 IU/mL, 0.7%. No evidence of recurring thromboembolism was observed. CONCLUSION: Using the conventional aPTT target range may lead to inappropriate dosing of UFH. Transitioning from the aPTT test to the anti-Xa assay is required to avoid the laborious validation of the aPTT HTR test, even though the anti-Xa assay is more expensive. Korean Society of Hematology; Korean Society of Blood and Marrow Transplantation; Korean Society of Pediatric Hematology-Oncology; Korean Society on Thrombosis and Hemostasis 2016-09 2016-09-23 /pmc/articles/PMC5054248/ /pubmed/27722127 http://dx.doi.org/10.5045/br.2016.51.3.171 Text en © 2016 Korean Society of Hematology http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Byun, Jung-Hyun Jang, In-Seok Kim, Jong Woo Koh, Eun-Ha Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title | Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title_full | Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title_fullStr | Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title_full_unstemmed | Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title_short | Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy |
title_sort | establishing the heparin therapeutic range using aptt and anti-xa measurements for monitoring unfractionated heparin therapy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054248/ https://www.ncbi.nlm.nih.gov/pubmed/27722127 http://dx.doi.org/10.5045/br.2016.51.3.171 |
work_keys_str_mv | AT byunjunghyun establishingtheheparintherapeuticrangeusingapttandantixameasurementsformonitoringunfractionatedheparintherapy AT janginseok establishingtheheparintherapeuticrangeusingapttandantixameasurementsformonitoringunfractionatedheparintherapy AT kimjongwoo establishingtheheparintherapeuticrangeusingapttandantixameasurementsformonitoringunfractionatedheparintherapy AT koheunha establishingtheheparintherapeuticrangeusingapttandantixameasurementsformonitoringunfractionatedheparintherapy |