Cargando…
Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques
BACKGROUND: Complications exclusive of new neurological deficits/injuries that follow extreme lateral interbody fusion (XLIF) and related lateral lumbar interbody techniques should be better recognized to determine the safety of these procedures. Unfortunately, a review of the XLIF literature did no...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054631/ https://www.ncbi.nlm.nih.gov/pubmed/27843680 http://dx.doi.org/10.4103/2152-7806.191071 |
_version_ | 1782458639021244416 |
---|---|
author | Epstein, Nancy E. |
author_facet | Epstein, Nancy E. |
author_sort | Epstein, Nancy E. |
collection | PubMed |
description | BACKGROUND: Complications exclusive of new neurological deficits/injuries that follow extreme lateral interbody fusion (XLIF) and related lateral lumbar interbody techniques should be better recognized to determine the safety of these procedures. Unfortunately, a review of the XLIF literature did not accurately reflect the frequency of these “other complications” as few US surgeons publish such adverse events that may lead to medicolegal suits. METHODS: Major complications occurring with XLIF included sympathectomy, major vascular injuries, bowel perforations, sterile seromas, and instrumentation failures. RESULTS: The frequency of sympathectomy was 4% for XLIF vs. 15% for anterior lumbar interbody fusion (ALIF). There were three major vascular injuries for XLIF; one fatal intraoperative event, one life-threatening retroperitoneal hematoma, and one iatrogenic lumbar artery pseudoaneurysm that was successfully embolized. Two bowel perforations were reported, whereas a third was a “direct communication.” One patient developed a sterile recurrent seroma due to vancomycin powder utilized for an XLIF. One study cited malpositioning of an XLIF cage resulting in a lateral L3–L4 extrusion, whereas the second series looked at the 45% risk of cage-overhang when XLIF devices were placed in the anterior one-third of the vertebral body. CONCLUSION: Excluding new neurological deficits, XLIF techniques resulted in multiple other major complications. However, these small numbers likely reflect just the tip of the iceberg (e.g., 10%) and the remaining 90% may never be known as many US-based spine surgeons fail to publish such adverse events as they are discoverable in a court of law and may lead to medicolegal suits. |
format | Online Article Text |
id | pubmed-5054631 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-50546312016-11-14 Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques Epstein, Nancy E. Surg Neurol Int Surgical Neurology International: Spine BACKGROUND: Complications exclusive of new neurological deficits/injuries that follow extreme lateral interbody fusion (XLIF) and related lateral lumbar interbody techniques should be better recognized to determine the safety of these procedures. Unfortunately, a review of the XLIF literature did not accurately reflect the frequency of these “other complications” as few US surgeons publish such adverse events that may lead to medicolegal suits. METHODS: Major complications occurring with XLIF included sympathectomy, major vascular injuries, bowel perforations, sterile seromas, and instrumentation failures. RESULTS: The frequency of sympathectomy was 4% for XLIF vs. 15% for anterior lumbar interbody fusion (ALIF). There were three major vascular injuries for XLIF; one fatal intraoperative event, one life-threatening retroperitoneal hematoma, and one iatrogenic lumbar artery pseudoaneurysm that was successfully embolized. Two bowel perforations were reported, whereas a third was a “direct communication.” One patient developed a sterile recurrent seroma due to vancomycin powder utilized for an XLIF. One study cited malpositioning of an XLIF cage resulting in a lateral L3–L4 extrusion, whereas the second series looked at the 45% risk of cage-overhang when XLIF devices were placed in the anterior one-third of the vertebral body. CONCLUSION: Excluding new neurological deficits, XLIF techniques resulted in multiple other major complications. However, these small numbers likely reflect just the tip of the iceberg (e.g., 10%) and the remaining 90% may never be known as many US-based spine surgeons fail to publish such adverse events as they are discoverable in a court of law and may lead to medicolegal suits. Medknow Publications & Media Pvt Ltd 2016-09-22 /pmc/articles/PMC5054631/ /pubmed/27843680 http://dx.doi.org/10.4103/2152-7806.191071 Text en Copyright: © 2016 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Neurology International: Spine Epstein, Nancy E. Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title | Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title_full | Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title_fullStr | Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title_full_unstemmed | Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title_short | Non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
title_sort | non-neurological major complications of extreme lateral and related lumbar interbody fusion techniques |
topic | Surgical Neurology International: Spine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054631/ https://www.ncbi.nlm.nih.gov/pubmed/27843680 http://dx.doi.org/10.4103/2152-7806.191071 |
work_keys_str_mv | AT epsteinnancye nonneurologicalmajorcomplicationsofextremelateralandrelatedlumbarinterbodyfusiontechniques |