Cargando…

Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy

PURPOSE: The purpose of this study was to evaluate an automated algorithm for detecting avascular area (AA) in optical coherence tomography angiograms (OCTAs) separated into three individual plexuses using a projection-resolved technique. METHODS: A 3 × 3 mm macular OCTA was obtained in 13 healthy a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Miao, Hwang, Thomas S., Dongye, Changlei, Wilson, David J., Huang, David, Jia, Yali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054727/
https://www.ncbi.nlm.nih.gov/pubmed/27699408
http://dx.doi.org/10.1167/iovs.16-19776
_version_ 1782458655869763584
author Zhang, Miao
Hwang, Thomas S.
Dongye, Changlei
Wilson, David J.
Huang, David
Jia, Yali
author_facet Zhang, Miao
Hwang, Thomas S.
Dongye, Changlei
Wilson, David J.
Huang, David
Jia, Yali
author_sort Zhang, Miao
collection PubMed
description PURPOSE: The purpose of this study was to evaluate an automated algorithm for detecting avascular area (AA) in optical coherence tomography angiograms (OCTAs) separated into three individual plexuses using a projection-resolved technique. METHODS: A 3 × 3 mm macular OCTA was obtained in 13 healthy and 13 mild nonproliferative diabetic retinopathy (NPDR) participants. A projection-resolved algorithm segmented OCTA into three vascular plexuses: superficial, intermediate, and deep. An automated algorithm detected AA in each of the three plexuses that were segmented and in the combined inner-retinal angiograms. We assessed the diagnostic accuracy of extrafoveal and total AA using segmented and combined angiograms, the agreement between automated and manual detection of AA, and the within-visit repeatability. RESULTS: The sum of extrafoveal AA from the segmented angiograms was larger in the NPDR group by 0.17 mm(2) (P < 0.001) and detected NPDR with 94.6% sensitivity (area under the receiver operating characteristic curve [AROC] = 0.99). In the combined inner-retinal angiograms, the extrafoveal AA was larger in the NPDR group by 0.01 mm(2) (P = 0.168) and detected NPDR with 26.9% sensitivity (AROC = 0.62). The total AA, inclusive of the foveal avascular zone, in the segmented and combined angiograms, detected NPDR with 23.1% and 7.7% sensitivity, respectively. The agreement between the manual and automated detection of AA had a Jaccard index of >0.8. The pooled SDs of AA were small compared with the difference in mean for control and NPDR groups. CONCLUSIONS: An algorithm to detect AA in OCTA separated into three individual plexuses using a projection-resolved algorithm accurately distinguishes mild NPDR from control eyes. Automatically detected AA agrees with manual delineation and is highly repeatable.
format Online
Article
Text
id pubmed-5054727
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-50547272016-10-11 Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy Zhang, Miao Hwang, Thomas S. Dongye, Changlei Wilson, David J. Huang, David Jia, Yali Invest Ophthalmol Vis Sci Retina PURPOSE: The purpose of this study was to evaluate an automated algorithm for detecting avascular area (AA) in optical coherence tomography angiograms (OCTAs) separated into three individual plexuses using a projection-resolved technique. METHODS: A 3 × 3 mm macular OCTA was obtained in 13 healthy and 13 mild nonproliferative diabetic retinopathy (NPDR) participants. A projection-resolved algorithm segmented OCTA into three vascular plexuses: superficial, intermediate, and deep. An automated algorithm detected AA in each of the three plexuses that were segmented and in the combined inner-retinal angiograms. We assessed the diagnostic accuracy of extrafoveal and total AA using segmented and combined angiograms, the agreement between automated and manual detection of AA, and the within-visit repeatability. RESULTS: The sum of extrafoveal AA from the segmented angiograms was larger in the NPDR group by 0.17 mm(2) (P < 0.001) and detected NPDR with 94.6% sensitivity (area under the receiver operating characteristic curve [AROC] = 0.99). In the combined inner-retinal angiograms, the extrafoveal AA was larger in the NPDR group by 0.01 mm(2) (P = 0.168) and detected NPDR with 26.9% sensitivity (AROC = 0.62). The total AA, inclusive of the foveal avascular zone, in the segmented and combined angiograms, detected NPDR with 23.1% and 7.7% sensitivity, respectively. The agreement between the manual and automated detection of AA had a Jaccard index of >0.8. The pooled SDs of AA were small compared with the difference in mean for control and NPDR groups. CONCLUSIONS: An algorithm to detect AA in OCTA separated into three individual plexuses using a projection-resolved algorithm accurately distinguishes mild NPDR from control eyes. Automatically detected AA agrees with manual delineation and is highly repeatable. The Association for Research in Vision and Ophthalmology 2016-10 /pmc/articles/PMC5054727/ /pubmed/27699408 http://dx.doi.org/10.1167/iovs.16-19776 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Retina
Zhang, Miao
Hwang, Thomas S.
Dongye, Changlei
Wilson, David J.
Huang, David
Jia, Yali
Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title_full Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title_fullStr Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title_full_unstemmed Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title_short Automated Quantification of Nonperfusion in Three Retinal Plexuses Using Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
title_sort automated quantification of nonperfusion in three retinal plexuses using projection-resolved optical coherence tomography angiography in diabetic retinopathy
topic Retina
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5054727/
https://www.ncbi.nlm.nih.gov/pubmed/27699408
http://dx.doi.org/10.1167/iovs.16-19776
work_keys_str_mv AT zhangmiao automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy
AT hwangthomass automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy
AT dongyechanglei automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy
AT wilsondavidj automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy
AT huangdavid automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy
AT jiayali automatedquantificationofnonperfusioninthreeretinalplexusesusingprojectionresolvedopticalcoherencetomographyangiographyindiabeticretinopathy