Improved precision with Hologic Apex software

SUMMARY: The precision of Hologic Apex v2.0 analysis software is significantly improved from Hologic Delphi v11.2 software and is comparable to GE Lunar Prodigy v7.5 software. Apex and Delphi precisions were, respectively, 1.0% vs. 1.2% (L1-L4 spine), 1.l % vs. 1.3% (total femur), 1.6% vs. 1.9% (fem...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, B., Lewiecki, E. M., Sherman, M., Lu, Y., Miller, P. D., Genant, H. K., Shepherd, J. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer London 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059410/
https://www.ncbi.nlm.nih.gov/pubmed/18373054
http://dx.doi.org/10.1007/s00198-008-0594-2
_version_ 1782459399898398720
author Fan, B.
Lewiecki, E. M.
Sherman, M.
Lu, Y.
Miller, P. D.
Genant, H. K.
Shepherd, J. A.
author_facet Fan, B.
Lewiecki, E. M.
Sherman, M.
Lu, Y.
Miller, P. D.
Genant, H. K.
Shepherd, J. A.
author_sort Fan, B.
collection PubMed
description SUMMARY: The precision of Hologic Apex v2.0 analysis software is significantly improved from Hologic Delphi v11.2 software and is comparable to GE Lunar Prodigy v7.5 software. Apex and Delphi precisions were, respectively, 1.0% vs. 1.2% (L1-L4 spine), 1.l % vs. 1.3% (total femur), 1.6% vs. 1.9% (femoral neck), and 0.7% vs. 0.9% (dual total femur). INTRODUCTION: Precision of bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA) is known to vary by manufacturer, model, and technologist. This study evaluated the precision of three analysis versions: Apex v2.0 and Delphi v11.2 (Hologic, Inc.), and Prodigy v7.5 (GE Healthcare, Inc.) independent of technologist skill. METHODS: Duplicate spine and dual hip scans on 90 women were acquired on both Delphi and Prodigy DXA systems at three clinics. BMD measures were converted to standardized BMD (sBMD) units. Precision errors were described as a root-mean-square (RMS) standard deviations and RMS percent coefficients of variation across the population. RESULTS: Apex and Delphi values were highly correlated (r ranged from 0.90 to 0.99). Excluding the right neck, the Apex precision error was found to be 20% to 25% lower than the Delphi (spine: 1.0% versus 1.2% (p < 0.05), total hip: 1.1% versus 1.3% (p < 0.05), right neck: 2.3% versus 2.6% (p > 0.1)). No statistically significant differences were found in the precision error of the Apex and Prodigy (p > 0.05) except for the right neck (2.3% versus 1.8% respectively, p = 0.03). CONCLUSION: The Apex software has significantly lower precision error compared to Delphi software with similar mean values, and similar precision to that of the Prodigy.
format Online
Article
Text
id pubmed-5059410
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Springer London
record_format MEDLINE/PubMed
spelling pubmed-50594102016-10-26 Improved precision with Hologic Apex software Fan, B. Lewiecki, E. M. Sherman, M. Lu, Y. Miller, P. D. Genant, H. K. Shepherd, J. A. Osteoporos Int Original Article SUMMARY: The precision of Hologic Apex v2.0 analysis software is significantly improved from Hologic Delphi v11.2 software and is comparable to GE Lunar Prodigy v7.5 software. Apex and Delphi precisions were, respectively, 1.0% vs. 1.2% (L1-L4 spine), 1.l % vs. 1.3% (total femur), 1.6% vs. 1.9% (femoral neck), and 0.7% vs. 0.9% (dual total femur). INTRODUCTION: Precision of bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA) is known to vary by manufacturer, model, and technologist. This study evaluated the precision of three analysis versions: Apex v2.0 and Delphi v11.2 (Hologic, Inc.), and Prodigy v7.5 (GE Healthcare, Inc.) independent of technologist skill. METHODS: Duplicate spine and dual hip scans on 90 women were acquired on both Delphi and Prodigy DXA systems at three clinics. BMD measures were converted to standardized BMD (sBMD) units. Precision errors were described as a root-mean-square (RMS) standard deviations and RMS percent coefficients of variation across the population. RESULTS: Apex and Delphi values were highly correlated (r ranged from 0.90 to 0.99). Excluding the right neck, the Apex precision error was found to be 20% to 25% lower than the Delphi (spine: 1.0% versus 1.2% (p < 0.05), total hip: 1.1% versus 1.3% (p < 0.05), right neck: 2.3% versus 2.6% (p > 0.1)). No statistically significant differences were found in the precision error of the Apex and Prodigy (p > 0.05) except for the right neck (2.3% versus 1.8% respectively, p = 0.03). CONCLUSION: The Apex software has significantly lower precision error compared to Delphi software with similar mean values, and similar precision to that of the Prodigy. Springer London 2008-03-29 2008 /pmc/articles/PMC5059410/ /pubmed/18373054 http://dx.doi.org/10.1007/s00198-008-0594-2 Text en © International Osteoporosis Foundation and National Osteoporosis Foundation 2008
spellingShingle Original Article
Fan, B.
Lewiecki, E. M.
Sherman, M.
Lu, Y.
Miller, P. D.
Genant, H. K.
Shepherd, J. A.
Improved precision with Hologic Apex software
title Improved precision with Hologic Apex software
title_full Improved precision with Hologic Apex software
title_fullStr Improved precision with Hologic Apex software
title_full_unstemmed Improved precision with Hologic Apex software
title_short Improved precision with Hologic Apex software
title_sort improved precision with hologic apex software
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059410/
https://www.ncbi.nlm.nih.gov/pubmed/18373054
http://dx.doi.org/10.1007/s00198-008-0594-2
work_keys_str_mv AT fanb improvedprecisionwithhologicapexsoftware
AT lewieckiem improvedprecisionwithhologicapexsoftware
AT shermanm improvedprecisionwithhologicapexsoftware
AT luy improvedprecisionwithhologicapexsoftware
AT millerpd improvedprecisionwithhologicapexsoftware
AT genanthk improvedprecisionwithhologicapexsoftware
AT shepherdja improvedprecisionwithhologicapexsoftware