Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059590/ https://www.ncbi.nlm.nih.gov/pubmed/27774312 http://dx.doi.org/10.1155/2016/1732476 |
_version_ | 1782459436082659328 |
---|---|
author | Mei, Ying Tang, Zhiping Li, Zhouyue Yang, Xiao |
author_facet | Mei, Ying Tang, Zhiping Li, Zhouyue Yang, Xiao |
author_sort | Mei, Ying |
collection | PubMed |
description | Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements. Results. ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements. Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number: ChiCTR-IPR-14005505. |
format | Online Article Text |
id | pubmed-5059590 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-50595902016-10-23 Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software Mei, Ying Tang, Zhiping Li, Zhouyue Yang, Xiao J Ophthalmol Research Article Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements. Results. ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements. Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number: ChiCTR-IPR-14005505. Hindawi Publishing Corporation 2016 2016-09-28 /pmc/articles/PMC5059590/ /pubmed/27774312 http://dx.doi.org/10.1155/2016/1732476 Text en Copyright © 2016 Ying Mei et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mei, Ying Tang, Zhiping Li, Zhouyue Yang, Xiao Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title | Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title_full | Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title_fullStr | Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title_full_unstemmed | Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title_short | Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software |
title_sort | repeatability and reproducibility of quantitative corneal shape analysis after orthokeratology treatment using image-pro plus software |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059590/ https://www.ncbi.nlm.nih.gov/pubmed/27774312 http://dx.doi.org/10.1155/2016/1732476 |
work_keys_str_mv | AT meiying repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware AT tangzhiping repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware AT lizhouyue repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware AT yangxiao repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware |