Cargando…

Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software

Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set...

Descripción completa

Detalles Bibliográficos
Autores principales: Mei, Ying, Tang, Zhiping, Li, Zhouyue, Yang, Xiao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059590/
https://www.ncbi.nlm.nih.gov/pubmed/27774312
http://dx.doi.org/10.1155/2016/1732476
_version_ 1782459436082659328
author Mei, Ying
Tang, Zhiping
Li, Zhouyue
Yang, Xiao
author_facet Mei, Ying
Tang, Zhiping
Li, Zhouyue
Yang, Xiao
author_sort Mei, Ying
collection PubMed
description Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements. Results. ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements. Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number: ChiCTR-IPR-14005505.
format Online
Article
Text
id pubmed-5059590
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-50595902016-10-23 Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software Mei, Ying Tang, Zhiping Li, Zhouyue Yang, Xiao J Ophthalmol Research Article Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using “Image-Pro Plus 6.0” software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements. Results. ICC analysis suggested “excellent” reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested “excellent” reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements. Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number: ChiCTR-IPR-14005505. Hindawi Publishing Corporation 2016 2016-09-28 /pmc/articles/PMC5059590/ /pubmed/27774312 http://dx.doi.org/10.1155/2016/1732476 Text en Copyright © 2016 Ying Mei et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Mei, Ying
Tang, Zhiping
Li, Zhouyue
Yang, Xiao
Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title_full Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title_fullStr Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title_full_unstemmed Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title_short Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software
title_sort repeatability and reproducibility of quantitative corneal shape analysis after orthokeratology treatment using image-pro plus software
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5059590/
https://www.ncbi.nlm.nih.gov/pubmed/27774312
http://dx.doi.org/10.1155/2016/1732476
work_keys_str_mv AT meiying repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware
AT tangzhiping repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware
AT lizhouyue repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware
AT yangxiao repeatabilityandreproducibilityofquantitativecornealshapeanalysisafterorthokeratologytreatmentusingimageproplussoftware