Cargando…

Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers

Establishing a wide therapeutic index (TI) for pre-clinical safety is important during lead optimization (LO) in research, prior to clinical development, although is often limited by a molecules physiochemical characteristics. Recent advances in the application of the innovative vibrating mesh spray...

Descripción completa

Detalles Bibliográficos
Autores principales: Fryer, Ryan M., Patel, Mita, Zhang, Xiaomei, Baum-Kroker, Katja S., Muthukumarana, Akalushi, Linehan, Brian, Tseng, Yin-Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5062032/
https://www.ncbi.nlm.nih.gov/pubmed/27790142
http://dx.doi.org/10.3389/fphar.2016.00368
_version_ 1782459695332589568
author Fryer, Ryan M.
Patel, Mita
Zhang, Xiaomei
Baum-Kroker, Katja S.
Muthukumarana, Akalushi
Linehan, Brian
Tseng, Yin-Chao
author_facet Fryer, Ryan M.
Patel, Mita
Zhang, Xiaomei
Baum-Kroker, Katja S.
Muthukumarana, Akalushi
Linehan, Brian
Tseng, Yin-Chao
author_sort Fryer, Ryan M.
collection PubMed
description Establishing a wide therapeutic index (TI) for pre-clinical safety is important during lead optimization (LO) in research, prior to clinical development, although is often limited by a molecules physiochemical characteristics. Recent advances in the application of the innovative vibrating mesh spray-drying technology to prepare amorphous solid dispersions may offer an opportunity to achieve high plasma concentrations of poorly soluble NCEs to enable testing and establishment of a wide TI in safety pharmacology studies. While some of the amorphous solid dispersion carriers are generally recognized as safe for clinical use, whether they are sufficiently benign to enable in vivo pharmacology studies has not been sufficiently demonstrated. Thus, the physical properties, and effect in a battery of in vivo safety pharmacology models, were assessed in three classes of polymers employed as spray-dried dispersion carriers. The polymers (HPMC-AS, Eudragit, PVAP) displayed low affinity with acetone/methanol, suitable for solvent-based spray drying. The water sorption of the polymers was moderate, and the degree of hysteresis of HPMC-AS was smaller than Eudragit and PVAP indicating the intermolecular interaction of water-cellulose molecules is weaker than water-acrylate or water-polyvinyl molecules. The polymer particles were well-suspended without aggregation with a mean particle size less than 3 μm in an aqueous vehicle. When tested in conscious Wistar Han rats in safety pharmacology models (n = 6–8/dose/polymer) investigating effects on CNS, gastrointestinal, and cardiovascular function, no liabilities were identified at any dose tested (30–300 mg/kg PO, suspension). In brief, the polymers had no effect in a modified Irwin test that included observational and evoked endpoints related to stereotypies, excitation, sedation, pain/anesthesia, autonomic balance, reflexes, and others. No effect of the polymers on gastric emptying or intestinal transit was observed when measured using a barium sulfate tracer material. Finally, in telemetry-instrumented rats the polymers had no effect on acute or 24-h mean blood pressure and heart rate values at doses up to 300 mg/kg. Thus, the properties of the three enteric polymers are appropriate as spray-dried dispersion carriers and were benign in a battery of safety pharmacology studies, demonstrating their applicability to enable in vivo safety pharmacology profiling of poorly soluble molecules during LO.
format Online
Article
Text
id pubmed-5062032
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-50620322016-10-27 Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers Fryer, Ryan M. Patel, Mita Zhang, Xiaomei Baum-Kroker, Katja S. Muthukumarana, Akalushi Linehan, Brian Tseng, Yin-Chao Front Pharmacol Pharmacology Establishing a wide therapeutic index (TI) for pre-clinical safety is important during lead optimization (LO) in research, prior to clinical development, although is often limited by a molecules physiochemical characteristics. Recent advances in the application of the innovative vibrating mesh spray-drying technology to prepare amorphous solid dispersions may offer an opportunity to achieve high plasma concentrations of poorly soluble NCEs to enable testing and establishment of a wide TI in safety pharmacology studies. While some of the amorphous solid dispersion carriers are generally recognized as safe for clinical use, whether they are sufficiently benign to enable in vivo pharmacology studies has not been sufficiently demonstrated. Thus, the physical properties, and effect in a battery of in vivo safety pharmacology models, were assessed in three classes of polymers employed as spray-dried dispersion carriers. The polymers (HPMC-AS, Eudragit, PVAP) displayed low affinity with acetone/methanol, suitable for solvent-based spray drying. The water sorption of the polymers was moderate, and the degree of hysteresis of HPMC-AS was smaller than Eudragit and PVAP indicating the intermolecular interaction of water-cellulose molecules is weaker than water-acrylate or water-polyvinyl molecules. The polymer particles were well-suspended without aggregation with a mean particle size less than 3 μm in an aqueous vehicle. When tested in conscious Wistar Han rats in safety pharmacology models (n = 6–8/dose/polymer) investigating effects on CNS, gastrointestinal, and cardiovascular function, no liabilities were identified at any dose tested (30–300 mg/kg PO, suspension). In brief, the polymers had no effect in a modified Irwin test that included observational and evoked endpoints related to stereotypies, excitation, sedation, pain/anesthesia, autonomic balance, reflexes, and others. No effect of the polymers on gastric emptying or intestinal transit was observed when measured using a barium sulfate tracer material. Finally, in telemetry-instrumented rats the polymers had no effect on acute or 24-h mean blood pressure and heart rate values at doses up to 300 mg/kg. Thus, the properties of the three enteric polymers are appropriate as spray-dried dispersion carriers and were benign in a battery of safety pharmacology studies, demonstrating their applicability to enable in vivo safety pharmacology profiling of poorly soluble molecules during LO. Frontiers Media S.A. 2016-10-13 /pmc/articles/PMC5062032/ /pubmed/27790142 http://dx.doi.org/10.3389/fphar.2016.00368 Text en Copyright © 2016 Fryer, Patel, Zhang, Baum-Kroker, Muthukumarana, Linehan and Tseng. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pharmacology
Fryer, Ryan M.
Patel, Mita
Zhang, Xiaomei
Baum-Kroker, Katja S.
Muthukumarana, Akalushi
Linehan, Brian
Tseng, Yin-Chao
Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title_full Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title_fullStr Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title_full_unstemmed Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title_short Physical Properties and Effect in a Battery of Safety Pharmacology Models for Three Structurally Distinct Enteric Polymers Employed as Spray-Dried Dispersion Carriers
title_sort physical properties and effect in a battery of safety pharmacology models for three structurally distinct enteric polymers employed as spray-dried dispersion carriers
topic Pharmacology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5062032/
https://www.ncbi.nlm.nih.gov/pubmed/27790142
http://dx.doi.org/10.3389/fphar.2016.00368
work_keys_str_mv AT fryerryanm physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT patelmita physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT zhangxiaomei physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT baumkrokerkatjas physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT muthukumaranaakalushi physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT linehanbrian physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers
AT tsengyinchao physicalpropertiesandeffectinabatteryofsafetypharmacologymodelsforthreestructurallydistinctentericpolymersemployedasspraydrieddispersioncarriers