Cargando…

A real-time ARMS PCR/high-resolution melt curve assay for the detection of the three primary mitochondrial mutations in Leber’s hereditary optic neuropathy

PURPOSE: Approximately 95% of patients who are diagnosed with Leber’s hereditary optic neuropathy (LHON) have one of three mitochondrial point mutations responsible for the disease, G3460A, G11778A, and T14484C. The purpose of this study was to develop a novel multiplex real-time amplification-refra...

Descripción completa

Detalles Bibliográficos
Autores principales: Ryan, Siobhan Eustace, Ryan, Fergus, O’Dwyer, Veronica, Neylan, Derek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Vision 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5063091/
https://www.ncbi.nlm.nih.gov/pubmed/27746671
Descripción
Sumario:PURPOSE: Approximately 95% of patients who are diagnosed with Leber’s hereditary optic neuropathy (LHON) have one of three mitochondrial point mutations responsible for the disease, G3460A, G11778A, and T14484C. The purpose of this study was to develop a novel multiplex real-time amplification-refractory mutation system (ARMS) PCR combined with high-resolution melt curves to identify the individual mutations involved. The study aimed to provide a more robust, cost- and time-effective mutation detection strategy than that offered with currently available methods. The assay reported in this study will allow diagnostic laboratories to avoid costly next-generation sequencing (NGS) assays for most patients with LHON and to focus resources on patients with unknown mutations that require further analysis. METHODS: The test uses a combination of multiplex allele-specific PCR (ARMS PCR) in combination with a high-resolution melt curve analysis to detect the presence of the mutations in G3460A, G11778A, and T14484C. PCR primer sets were designed to produce a control PCR product and PCR products only in the presence of the mutations in 3460A, 11778A, and 14484C in a multiplex single tube format. Products produce discrete well-separated melt curves to clearly detect the mutations. RESULTS: This novel real-time ARMS PCR/high-resolution melt curve assay accurately detected 95% of the mutations that cause LHON. The test has proved to be robust, cost- and time-effective with the real-time closed tube system taking approximately 1 h to complete. CONCLUSIONS: A novel real-time ARMS PCR/high-resolution melt curve assay is described for the detection of the three primary mitochondrial mutations in LHON. This test provides a simple, robust, easy-to-read output that is cost- and time-effective, thus providing an alternative method to individual endpoint PCR-restriction fragment length polymorphism (RFLP), PCR followed by Sanger sequencing or pyrosequencing, and next-generation sequencing.