Cargando…

Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity

Transcutaneous assessment of fluorescein isothiocyanate (FITC)‐sinistrin clearance using a small animal imager has recently been validated as an accurate method for the measurement of glomerular filtration rate (GFR) in freely moving rats. This technique involves a brief, light period of anesthesia...

Descripción completa

Detalles Bibliográficos
Autores principales: Hilliard, Lucinda M., Denton, Kate M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064127/
http://dx.doi.org/10.14814/phy2.12723
_version_ 1782460094258085888
author Hilliard, Lucinda M.
Denton, Kate M.
author_facet Hilliard, Lucinda M.
Denton, Kate M.
author_sort Hilliard, Lucinda M.
collection PubMed
description Transcutaneous assessment of fluorescein isothiocyanate (FITC)‐sinistrin clearance using a small animal imager has recently been validated as an accurate method for the measurement of glomerular filtration rate (GFR) in freely moving rats. This technique involves a brief, light period of anesthesia during which the imager is adhered to the rat and FITC‐sinistrin is administered. The rat is then moved to an experimental chamber where it is housed unrestrained for a 2‐h data collection period. This study assessed the impact of the experimental protocol on mean arterial pressure (MAP), heart rate, and locomotor activity in adult Sprague Dawley rats using radiotelemetry given that anesthesia and stress are known to affect arterial pressure and kidney function. These data were compared with time‐equivalent measurements made in the same rats at rest. MAP was low following anesthesia, but increased within 15 min and remained stable thereafter. Heart rate was not affected by the GFR protocol. Locomotor activity increased following anesthesia before decreasing to relatively low levels during the final 75‐min, the approximate period from which GFR is calculated. Moreover, MAP, heart rate, and locomotor activity during the final 75‐min of the data collection period were not different to that observed during an equivalent time period at baseline. Taken together, our findings suggest that this recently developed minimally invasive procedure for the measurement of GFR in unanesthetized rats does not negatively impact arterial pressure, heart rate, or locomotor activity. Thus, it is likely to be a valuable implement for acquiring serial measurements of GFR in unanesthetized rats.
format Online
Article
Text
id pubmed-5064127
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50641272016-10-24 Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity Hilliard, Lucinda M. Denton, Kate M. Physiol Rep Original Research Transcutaneous assessment of fluorescein isothiocyanate (FITC)‐sinistrin clearance using a small animal imager has recently been validated as an accurate method for the measurement of glomerular filtration rate (GFR) in freely moving rats. This technique involves a brief, light period of anesthesia during which the imager is adhered to the rat and FITC‐sinistrin is administered. The rat is then moved to an experimental chamber where it is housed unrestrained for a 2‐h data collection period. This study assessed the impact of the experimental protocol on mean arterial pressure (MAP), heart rate, and locomotor activity in adult Sprague Dawley rats using radiotelemetry given that anesthesia and stress are known to affect arterial pressure and kidney function. These data were compared with time‐equivalent measurements made in the same rats at rest. MAP was low following anesthesia, but increased within 15 min and remained stable thereafter. Heart rate was not affected by the GFR protocol. Locomotor activity increased following anesthesia before decreasing to relatively low levels during the final 75‐min, the approximate period from which GFR is calculated. Moreover, MAP, heart rate, and locomotor activity during the final 75‐min of the data collection period were not different to that observed during an equivalent time period at baseline. Taken together, our findings suggest that this recently developed minimally invasive procedure for the measurement of GFR in unanesthetized rats does not negatively impact arterial pressure, heart rate, or locomotor activity. Thus, it is likely to be a valuable implement for acquiring serial measurements of GFR in unanesthetized rats. John Wiley and Sons Inc. 2016-10-10 /pmc/articles/PMC5064127/ http://dx.doi.org/10.14814/phy2.12723 Text en © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Hilliard, Lucinda M.
Denton, Kate M.
Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title_full Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title_fullStr Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title_full_unstemmed Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title_short Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
title_sort transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure, heart rate, and activity
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064127/
http://dx.doi.org/10.14814/phy2.12723
work_keys_str_mv AT hilliardlucindam transcutaneousassessmentofglomerularfiltrationrateinunanesthetizedratsusingasmallanimalimagerimpactonarterialpressureheartrateandactivity
AT dentonkatem transcutaneousassessmentofglomerularfiltrationrateinunanesthetizedratsusingasmallanimalimagerimpactonarterialpressureheartrateandactivity