Cargando…

Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials

Long‐range gamma band EEG oscillations mediate information transmission between distant brain regions. Gamma band‐based coupling may not be restricted to cortex‐to‐cortex communication but may include extracortical parts of the visual system. The retinogram and visual event‐related evoked potentials...

Descripción completa

Detalles Bibliográficos
Autores principales: Todorov, Mihail I., Kékesi, Katalin A., Borhegyi, Zsolt, Galambos, Robert, Juhász, Gábor, Hudetz, Anthony G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064138/
https://www.ncbi.nlm.nih.gov/pubmed/27702884
http://dx.doi.org/10.14814/phy2.12986
_version_ 1782460096884768768
author Todorov, Mihail I.
Kékesi, Katalin A.
Borhegyi, Zsolt
Galambos, Robert
Juhász, Gábor
Hudetz, Anthony G.
author_facet Todorov, Mihail I.
Kékesi, Katalin A.
Borhegyi, Zsolt
Galambos, Robert
Juhász, Gábor
Hudetz, Anthony G.
author_sort Todorov, Mihail I.
collection PubMed
description Long‐range gamma band EEG oscillations mediate information transmission between distant brain regions. Gamma band‐based coupling may not be restricted to cortex‐to‐cortex communication but may include extracortical parts of the visual system. The retinogram and visual event‐related evoked potentials exhibit time‐locked, forward propagating oscillations that are candidates of gamma oscillatory coupling between the retina and the visual cortex. In this study, we tested if this gamma coupling is present as indicated by the coherence of gamma‐range (70–200 Hz) oscillatory potentials (OPs) recorded simultaneously from the retina and the primary visual cortex in freely moving, adult rats. We found significant retino‐cortical OP coherence in a wide range of stimulus duration (0.01–1000 msec), stimulus intensity (800–5000 mcd/mm(2)), interstimulus interval (10–400 msec), and stimulus frequency (0.25–25 Hz). However, at low stimulus frequencies, the OPs were time‐locked, flickering light at 25 Hz entrained continuous OP coherence (steady‐state response, SSR). Our results suggest that the retina and the visual cortex exhibit oscillatory coupling at high‐gamma frequency with precise time locking and synchronization of information transfer from the retina to the visual cortex, similar to cortico‐cortical gamma coupling. The temporal fusion of retino‐cortical gamma coherence at stimulus rates of theater movies may explain the mechanism of the visual illusion of continuity. How visual perception depends on early transformations of ascending sensory information is incompletely understood. By simultaneous measurement of flash‐evoked potentials in the retina and the visual cortex in awake, freely moving rats, we demonstrate for the first time that time‐locked gamma oscillatory potentials exhibit stable retino‐cortical synchrony across a wide range of stimulus parameters and that the temporal continuity of coherence changes with stimulus frequency according to the expected change in the visual illusion of continuity.
format Online
Article
Text
id pubmed-5064138
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50641382016-10-24 Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials Todorov, Mihail I. Kékesi, Katalin A. Borhegyi, Zsolt Galambos, Robert Juhász, Gábor Hudetz, Anthony G. Physiol Rep Original Research Long‐range gamma band EEG oscillations mediate information transmission between distant brain regions. Gamma band‐based coupling may not be restricted to cortex‐to‐cortex communication but may include extracortical parts of the visual system. The retinogram and visual event‐related evoked potentials exhibit time‐locked, forward propagating oscillations that are candidates of gamma oscillatory coupling between the retina and the visual cortex. In this study, we tested if this gamma coupling is present as indicated by the coherence of gamma‐range (70–200 Hz) oscillatory potentials (OPs) recorded simultaneously from the retina and the primary visual cortex in freely moving, adult rats. We found significant retino‐cortical OP coherence in a wide range of stimulus duration (0.01–1000 msec), stimulus intensity (800–5000 mcd/mm(2)), interstimulus interval (10–400 msec), and stimulus frequency (0.25–25 Hz). However, at low stimulus frequencies, the OPs were time‐locked, flickering light at 25 Hz entrained continuous OP coherence (steady‐state response, SSR). Our results suggest that the retina and the visual cortex exhibit oscillatory coupling at high‐gamma frequency with precise time locking and synchronization of information transfer from the retina to the visual cortex, similar to cortico‐cortical gamma coupling. The temporal fusion of retino‐cortical gamma coherence at stimulus rates of theater movies may explain the mechanism of the visual illusion of continuity. How visual perception depends on early transformations of ascending sensory information is incompletely understood. By simultaneous measurement of flash‐evoked potentials in the retina and the visual cortex in awake, freely moving rats, we demonstrate for the first time that time‐locked gamma oscillatory potentials exhibit stable retino‐cortical synchrony across a wide range of stimulus parameters and that the temporal continuity of coherence changes with stimulus frequency according to the expected change in the visual illusion of continuity. John Wiley and Sons Inc. 2016-10-04 /pmc/articles/PMC5064138/ /pubmed/27702884 http://dx.doi.org/10.14814/phy2.12986 Text en © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Todorov, Mihail I.
Kékesi, Katalin A.
Borhegyi, Zsolt
Galambos, Robert
Juhász, Gábor
Hudetz, Anthony G.
Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title_full Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title_fullStr Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title_full_unstemmed Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title_short Retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
title_sort retino‐cortical stimulus frequency‐dependent gamma coupling: evidence and functional implications of oscillatory potentials
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064138/
https://www.ncbi.nlm.nih.gov/pubmed/27702884
http://dx.doi.org/10.14814/phy2.12986
work_keys_str_mv AT todorovmihaili retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials
AT kekesikatalina retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials
AT borhegyizsolt retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials
AT galambosrobert retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials
AT juhaszgabor retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials
AT hudetzanthonyg retinocorticalstimulusfrequencydependentgammacouplingevidenceandfunctionalimplicationsofoscillatorypotentials