Cargando…
Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction
Cardiac power, the product of aortic flow and blood pressure, appears to be a fundamental cardiovascular parameter. The simplified version named cardiac power output (CPO), calculated as the product of cardiac output (CO) in L/min and mean arterial pressure (MAP) in mmHg divided by 451, has shown gr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064141/ https://www.ncbi.nlm.nih.gov/pubmed/27702881 http://dx.doi.org/10.14814/phy2.12989 |
_version_ | 1782460097599897600 |
---|---|
author | Rimehaug, Audun E. Skogvoll, Eirik Aadahl, Petter Lyng, Oddveig Nordhaug, Dag O. Løvstakken, Lasse Kirkeby‐Garstad, Idar |
author_facet | Rimehaug, Audun E. Skogvoll, Eirik Aadahl, Petter Lyng, Oddveig Nordhaug, Dag O. Løvstakken, Lasse Kirkeby‐Garstad, Idar |
author_sort | Rimehaug, Audun E. |
collection | PubMed |
description | Cardiac power, the product of aortic flow and blood pressure, appears to be a fundamental cardiovascular parameter. The simplified version named cardiac power output (CPO), calculated as the product of cardiac output (CO) in L/min and mean arterial pressure (MAP) in mmHg divided by 451, has shown great ability to predict outcome in a broad spectrum of cardiac disease. Beat‐by‐beat evaluation of cardiac power (PWR) therefore appears to be a possibly valuable addition when monitoring circulatory unstable patients, providing parameters of overall cardiovascular function. We have developed a minimally invasive system for cardiac power measurement, and aimed in this study to compare this system to an invasive method (ttPWR). Seven male anesthetized farm pigs were included. A laptop with in‐house software gathered audio from Doppler signals of aortic flow and blood pressure from the patient monitor to continuously calculate and display a minimally invasive cardiac power trace (uPWR). The time integral per cardiac cycle (uPWR‐integral) represents cardiac work, and was compared to the invasive counterpart (ttPWR‐integral). Signals were obtained at baseline, during mechanically manipulated preload and afterload, before and after induced global ischemic left ventricular dysfunction. We found that the uPWR‐integral overestimated compared to the ttPWR‐integral by about 10% (P < 0.001) in both normal hearts and during ventricular dysfunction. Bland–Altman limits of agreement were at +0.060 and −0.054 J, without increasing spread over the range. In conclusion we find that the minimally invasive system follows its invasive counterpart, and is ready for clinical research of cardiac power parameters. |
format | Online Article Text |
id | pubmed-5064141 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-50641412016-10-24 Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction Rimehaug, Audun E. Skogvoll, Eirik Aadahl, Petter Lyng, Oddveig Nordhaug, Dag O. Løvstakken, Lasse Kirkeby‐Garstad, Idar Physiol Rep Original Research Cardiac power, the product of aortic flow and blood pressure, appears to be a fundamental cardiovascular parameter. The simplified version named cardiac power output (CPO), calculated as the product of cardiac output (CO) in L/min and mean arterial pressure (MAP) in mmHg divided by 451, has shown great ability to predict outcome in a broad spectrum of cardiac disease. Beat‐by‐beat evaluation of cardiac power (PWR) therefore appears to be a possibly valuable addition when monitoring circulatory unstable patients, providing parameters of overall cardiovascular function. We have developed a minimally invasive system for cardiac power measurement, and aimed in this study to compare this system to an invasive method (ttPWR). Seven male anesthetized farm pigs were included. A laptop with in‐house software gathered audio from Doppler signals of aortic flow and blood pressure from the patient monitor to continuously calculate and display a minimally invasive cardiac power trace (uPWR). The time integral per cardiac cycle (uPWR‐integral) represents cardiac work, and was compared to the invasive counterpart (ttPWR‐integral). Signals were obtained at baseline, during mechanically manipulated preload and afterload, before and after induced global ischemic left ventricular dysfunction. We found that the uPWR‐integral overestimated compared to the ttPWR‐integral by about 10% (P < 0.001) in both normal hearts and during ventricular dysfunction. Bland–Altman limits of agreement were at +0.060 and −0.054 J, without increasing spread over the range. In conclusion we find that the minimally invasive system follows its invasive counterpart, and is ready for clinical research of cardiac power parameters. John Wiley and Sons Inc. 2016-10-04 /pmc/articles/PMC5064141/ /pubmed/27702881 http://dx.doi.org/10.14814/phy2.12989 Text en © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Rimehaug, Audun E. Skogvoll, Eirik Aadahl, Petter Lyng, Oddveig Nordhaug, Dag O. Løvstakken, Lasse Kirkeby‐Garstad, Idar Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title | Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title_full | Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title_fullStr | Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title_full_unstemmed | Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title_short | Minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
title_sort | minimally invasive beat‐by‐beat monitoring of cardiac power in normal hearts and during acute ventricular dysfunction |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5064141/ https://www.ncbi.nlm.nih.gov/pubmed/27702881 http://dx.doi.org/10.14814/phy2.12989 |
work_keys_str_mv | AT rimehaugaudune minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT skogvolleirik minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT aadahlpetter minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT lyngoddveig minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT nordhaugdago minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT løvstakkenlasse minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction AT kirkebygarstadidar minimallyinvasivebeatbybeatmonitoringofcardiacpowerinnormalheartsandduringacuteventriculardysfunction |