Cargando…
Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study
OBJECTIVE: Our aim was to compare the compression quality, exercise intensity, and energy expenditure in 5-minute single-rescuer cardiopulmonary resuscitation (CPR) using 15:1 or 30:2 compression-to-ventilation (C:V) ratios or chest compression only (CCO). METHODS: This was a randomized, crossover m...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Emergency Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5065337/ https://www.ncbi.nlm.nih.gov/pubmed/27752633 http://dx.doi.org/10.15441/ceem.15.105 |
_version_ | 1782460311724359680 |
---|---|
author | Kwak, Se-Jung Kim, Young-Min Baek, Hee Jin Kim, Se Hong Yim, Hyeon Woo |
author_facet | Kwak, Se-Jung Kim, Young-Min Baek, Hee Jin Kim, Se Hong Yim, Hyeon Woo |
author_sort | Kwak, Se-Jung |
collection | PubMed |
description | OBJECTIVE: Our aim was to compare the compression quality, exercise intensity, and energy expenditure in 5-minute single-rescuer cardiopulmonary resuscitation (CPR) using 15:1 or 30:2 compression-to-ventilation (C:V) ratios or chest compression only (CCO). METHODS: This was a randomized, crossover manikin study. Medical students were randomized to perform either type of CPR and do the others with intervals of at least 1 day. We measured compression quality, ratings of perceived exertion (RPE) score, heart rate, maximal oxygen uptake, and energy expenditure during CPR. RESULTS: Forty-seven students were recruited. Mean compression rates did not differ between the 3 groups. However, the mean percentage of adequate compressions in the CCO group was significantly lower than that of the 15:1 or 30:2 group (31.2±30.3% vs. 55.1±37.5% vs. 54.0±36.9%, respectively; P<0.001) and the difference occurred within the first minute. The RPE score in each minute and heart rate change in the CCO group was significantly higher than those of the C:V ratio groups. There was no significant difference in maximal oxygen uptake between the 3 groups. Energy expenditure in the CCO group was relatively lower than that of the 2 C:V ratio groups. CONCLUSION: CPR using a 15:1 C:V ratio may provide a compression quality and exercise intensity comparable to those obtained using a 30:2 C:V ratio. An earlier decrease in compression quality and increase in RPE and heart rate could be produced by CCO CPR compared with 15:1 or 30:2 C:V ratios with relatively lower oxygen uptake and energy expenditure. |
format | Online Article Text |
id | pubmed-5065337 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Emergency Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-50653372016-10-17 Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study Kwak, Se-Jung Kim, Young-Min Baek, Hee Jin Kim, Se Hong Yim, Hyeon Woo Clin Exp Emerg Med Original Article OBJECTIVE: Our aim was to compare the compression quality, exercise intensity, and energy expenditure in 5-minute single-rescuer cardiopulmonary resuscitation (CPR) using 15:1 or 30:2 compression-to-ventilation (C:V) ratios or chest compression only (CCO). METHODS: This was a randomized, crossover manikin study. Medical students were randomized to perform either type of CPR and do the others with intervals of at least 1 day. We measured compression quality, ratings of perceived exertion (RPE) score, heart rate, maximal oxygen uptake, and energy expenditure during CPR. RESULTS: Forty-seven students were recruited. Mean compression rates did not differ between the 3 groups. However, the mean percentage of adequate compressions in the CCO group was significantly lower than that of the 15:1 or 30:2 group (31.2±30.3% vs. 55.1±37.5% vs. 54.0±36.9%, respectively; P<0.001) and the difference occurred within the first minute. The RPE score in each minute and heart rate change in the CCO group was significantly higher than those of the C:V ratio groups. There was no significant difference in maximal oxygen uptake between the 3 groups. Energy expenditure in the CCO group was relatively lower than that of the 2 C:V ratio groups. CONCLUSION: CPR using a 15:1 C:V ratio may provide a compression quality and exercise intensity comparable to those obtained using a 30:2 C:V ratio. An earlier decrease in compression quality and increase in RPE and heart rate could be produced by CCO CPR compared with 15:1 or 30:2 C:V ratios with relatively lower oxygen uptake and energy expenditure. The Korean Society of Emergency Medicine 2016-09-30 /pmc/articles/PMC5065337/ /pubmed/27752633 http://dx.doi.org/10.15441/ceem.15.105 Text en Copyright © 2016 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Original Article Kwak, Se-Jung Kim, Young-Min Baek, Hee Jin Kim, Se Hong Yim, Hyeon Woo Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title | Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title_full | Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title_fullStr | Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title_full_unstemmed | Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title_short | Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
title_sort | chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5065337/ https://www.ncbi.nlm.nih.gov/pubmed/27752633 http://dx.doi.org/10.15441/ceem.15.105 |
work_keys_str_mv | AT kwaksejung chestcompressionqualityexerciseintensityandenergyexpenditureduringcardiopulmonaryresuscitationusingcompressiontoventilationratiosof151or302orchestcompressiononlyarandomizedcrossovermanikinstudy AT kimyoungmin chestcompressionqualityexerciseintensityandenergyexpenditureduringcardiopulmonaryresuscitationusingcompressiontoventilationratiosof151or302orchestcompressiononlyarandomizedcrossovermanikinstudy AT baekheejin chestcompressionqualityexerciseintensityandenergyexpenditureduringcardiopulmonaryresuscitationusingcompressiontoventilationratiosof151or302orchestcompressiononlyarandomizedcrossovermanikinstudy AT kimsehong chestcompressionqualityexerciseintensityandenergyexpenditureduringcardiopulmonaryresuscitationusingcompressiontoventilationratiosof151or302orchestcompressiononlyarandomizedcrossovermanikinstudy AT yimhyeonwoo chestcompressionqualityexerciseintensityandenergyexpenditureduringcardiopulmonaryresuscitationusingcompressiontoventilationratiosof151or302orchestcompressiononlyarandomizedcrossovermanikinstudy |