Cargando…

Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications

Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfa...

Descripción completa

Detalles Bibliográficos
Autores principales: Fani, Simone, Bianchi, Matteo, Jain, Sonal, Pimenta Neto, José Simões, Boege, Scott, Grioli, Giorgio, Bicchi, Antonio, Santello, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066092/
https://www.ncbi.nlm.nih.gov/pubmed/27799908
http://dx.doi.org/10.3389/fnbot.2016.00011
_version_ 1782460420527751168
author Fani, Simone
Bianchi, Matteo
Jain, Sonal
Pimenta Neto, José Simões
Boege, Scott
Grioli, Giorgio
Bicchi, Antonio
Santello, Marco
author_facet Fani, Simone
Bianchi, Matteo
Jain, Sonal
Pimenta Neto, José Simões
Boege, Scott
Grioli, Giorgio
Bicchi, Antonio
Santello, Marco
author_sort Fani, Simone
collection PubMed
description Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human–robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the highest coherence with hand movements. Our results represent a first step toward a more effective and intuitive control of myoelectric hand prostheses.
format Online
Article
Text
id pubmed-5066092
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-50660922016-10-31 Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications Fani, Simone Bianchi, Matteo Jain, Sonal Pimenta Neto, José Simões Boege, Scott Grioli, Giorgio Bicchi, Antonio Santello, Marco Front Neurorobot Neuroscience Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human–robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the highest coherence with hand movements. Our results represent a first step toward a more effective and intuitive control of myoelectric hand prostheses. Frontiers Media S.A. 2016-10-17 /pmc/articles/PMC5066092/ /pubmed/27799908 http://dx.doi.org/10.3389/fnbot.2016.00011 Text en Copyright © 2016 Fani, Bianchi, Jain, Pimenta Neto, Boege, Grioli, Bicchi and Santello. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Fani, Simone
Bianchi, Matteo
Jain, Sonal
Pimenta Neto, José Simões
Boege, Scott
Grioli, Giorgio
Bicchi, Antonio
Santello, Marco
Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title_full Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title_fullStr Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title_full_unstemmed Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title_short Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications
title_sort assessment of myoelectric controller performance and kinematic behavior of a novel soft synergy-inspired robotic hand for prosthetic applications
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066092/
https://www.ncbi.nlm.nih.gov/pubmed/27799908
http://dx.doi.org/10.3389/fnbot.2016.00011
work_keys_str_mv AT fanisimone assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT bianchimatteo assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT jainsonal assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT pimentanetojosesimoes assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT boegescott assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT grioligiorgio assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT bicchiantonio assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications
AT santellomarco assessmentofmyoelectriccontrollerperformanceandkinematicbehaviorofanovelsoftsynergyinspiredrobotichandforprostheticapplications