An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years

OBJECTIVE: The purpose of this analysis was to compare observer‐rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. METHODS: The Functional Low‐Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients impla...

Descripción completa

Detalles Bibliográficos
Autores principales: Geruschat, Duane R, Richards, Thomas P, Arditi, Aries, da Cruz, Lyndon, Dagnelie, Gislin, Dorn, Jessy D, Duncan, Jacque L, Ho, Allen C, Olmos de Koo, Lisa C, Sahel, José‐Alain, Stanga, Paulo E, Thumann, Gabriele, Wang, Vizhong, Greenberg, Robert J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066820/
https://www.ncbi.nlm.nih.gov/pubmed/26804484
http://dx.doi.org/10.1111/cxo.12359
_version_ 1782460546582315008
author Geruschat, Duane R
Richards, Thomas P
Arditi, Aries
da Cruz, Lyndon
Dagnelie, Gislin
Dorn, Jessy D
Duncan, Jacque L
Ho, Allen C
Olmos de Koo, Lisa C
Sahel, José‐Alain
Stanga, Paulo E
Thumann, Gabriele
Wang, Vizhong
Greenberg, Robert J
author_facet Geruschat, Duane R
Richards, Thomas P
Arditi, Aries
da Cruz, Lyndon
Dagnelie, Gislin
Dorn, Jessy D
Duncan, Jacque L
Ho, Allen C
Olmos de Koo, Lisa C
Sahel, José‐Alain
Stanga, Paulo E
Thumann, Gabriele
Wang, Vizhong
Greenberg, Robert J
author_sort Geruschat, Duane R
collection PubMed
description OBJECTIVE: The purpose of this analysis was to compare observer‐rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. METHODS: The Functional Low‐Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow‐up of 36 months. FLORA is a multi‐component instrument that consists in part of observer‐rated assessment of 35 tasks completed with the device ON versus OFF. The ease with which a patient completes a task is scored using a four‐point scale, ranging from easy (score of 1) to impossible (score of 4). The tasks are evaluated individually and organised into four discrete domains, including ‘Visual orientation’, ‘Visual mobility’, ‘Daily life and ‘Interaction with others’. RESULTS: Twenty‐six patients completed each of the 35 tasks. Overall, 24 out of 35 tasks (69 per cent) were statistically significantly easier to achieve with the device ON versus OFF. In each of the four domains, patients’ performances were significantly better (p < 0.05) with the device ON versus OFF, ranging from 19 to 38 per cent improvement. CONCLUSION: Patients with an Argus II Retinal Prosthesis implanted for 18 to 44 months (mean 36 months), demonstrated significantly improved completion of vision‐related tasks with the device ON versus OFF.
format Online
Article
Text
id pubmed-5066820
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50668202016-11-01 An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years Geruschat, Duane R Richards, Thomas P Arditi, Aries da Cruz, Lyndon Dagnelie, Gislin Dorn, Jessy D Duncan, Jacque L Ho, Allen C Olmos de Koo, Lisa C Sahel, José‐Alain Stanga, Paulo E Thumann, Gabriele Wang, Vizhong Greenberg, Robert J Clin Exp Optom Research Papers OBJECTIVE: The purpose of this analysis was to compare observer‐rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. METHODS: The Functional Low‐Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow‐up of 36 months. FLORA is a multi‐component instrument that consists in part of observer‐rated assessment of 35 tasks completed with the device ON versus OFF. The ease with which a patient completes a task is scored using a four‐point scale, ranging from easy (score of 1) to impossible (score of 4). The tasks are evaluated individually and organised into four discrete domains, including ‘Visual orientation’, ‘Visual mobility’, ‘Daily life and ‘Interaction with others’. RESULTS: Twenty‐six patients completed each of the 35 tasks. Overall, 24 out of 35 tasks (69 per cent) were statistically significantly easier to achieve with the device ON versus OFF. In each of the four domains, patients’ performances were significantly better (p < 0.05) with the device ON versus OFF, ranging from 19 to 38 per cent improvement. CONCLUSION: Patients with an Argus II Retinal Prosthesis implanted for 18 to 44 months (mean 36 months), demonstrated significantly improved completion of vision‐related tasks with the device ON versus OFF. John Wiley and Sons Inc. 2016-01-24 2016-05 /pmc/articles/PMC5066820/ /pubmed/26804484 http://dx.doi.org/10.1111/cxo.12359 Text en © 2016 The Authors Clinical and Experimental Optometry published by John Wiley & Sons Australia, Ltd on behalf of Optometry Australia This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Papers
Geruschat, Duane R
Richards, Thomas P
Arditi, Aries
da Cruz, Lyndon
Dagnelie, Gislin
Dorn, Jessy D
Duncan, Jacque L
Ho, Allen C
Olmos de Koo, Lisa C
Sahel, José‐Alain
Stanga, Paulo E
Thumann, Gabriele
Wang, Vizhong
Greenberg, Robert J
An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title_full An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title_fullStr An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title_full_unstemmed An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title_short An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years
title_sort analysis of observer‐rated functional vision in patients implanted with the argus ii retinal prosthesis system at three years
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066820/
https://www.ncbi.nlm.nih.gov/pubmed/26804484
http://dx.doi.org/10.1111/cxo.12359
work_keys_str_mv AT geruschatduaner ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT richardsthomasp ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT arditiaries ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dacruzlyndon ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dagneliegislin ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dornjessyd ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT duncanjacquel ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT hoallenc ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT olmosdekoolisac ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT saheljosealain ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT stangapauloe ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT thumanngabriele ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT wangvizhong ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT greenbergrobertj ananalysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT geruschatduaner analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT richardsthomasp analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT arditiaries analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dacruzlyndon analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dagneliegislin analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT dornjessyd analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT duncanjacquel analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT hoallenc analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT olmosdekoolisac analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT saheljosealain analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT stangapauloe analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT thumanngabriele analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT wangvizhong analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears
AT greenbergrobertj analysisofobserverratedfunctionalvisioninpatientsimplantedwiththeargusiiretinalprosthesissystematthreeyears