Cargando…
Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses
PURPOSE: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs). METHODS: This study was a retrospective review of clinical records. All patients who were seen between January 200...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066995/ https://www.ncbi.nlm.nih.gov/pubmed/27784985 http://dx.doi.org/10.2147/OPTH.S114890 |
_version_ | 1782460578612117504 |
---|---|
author | Gibbons, Allister Ali, Tayyeba K Waren, Daniel P Donaldson, Kendall E |
author_facet | Gibbons, Allister Ali, Tayyeba K Waren, Daniel P Donaldson, Kendall E |
author_sort | Gibbons, Allister |
collection | PubMed |
description | PURPOSE: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs). METHODS: This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual performance after presbyopia-correcting IOL implantation were included in the study. A single treating physician, who determined the most probable cause of dissatisfaction, decided which interventions to pursue following the initial consultation. RESULTS: Data from 74 eyes of 49 patients were analyzed. The most common cause for complaint was blurry or foggy vision both for distance and near (68%). Complaints were most frequently attributed to residual refractive error (57%) and dry eye (35%). The most common interventions pursued were treatment of refractive error with glasses or contact lenses (46%) and treatment for dry eye (24%). Corneal laser vision correction was done in 8% of eyes; 7% required an IOL exchange. After the interventions, 45% of patients had completed resolution of symptoms, 23% of patients were partially satisfied with the results, and 32% remained completely dissatisfied with the final results. CONCLUSION: The most identifiable causes of dissatisfaction after presbyopia-correcting IOL implantation are residual refractive error and dry eye. Most patients can be managed with conservative treatment, though a significant number of patients remained unsatisfied despite multiple measures. |
format | Online Article Text |
id | pubmed-5066995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-50669952016-10-26 Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses Gibbons, Allister Ali, Tayyeba K Waren, Daniel P Donaldson, Kendall E Clin Ophthalmol Original Research PURPOSE: The purpose of this study was to assess the causes and possible solutions for patient dissatisfaction after the implantation of presbyopia-correcting intraocular lenses (IOLs). METHODS: This study was a retrospective review of clinical records. All patients who were seen between January 2009 and December 2013 whose primary reason for consultation was dissatisfaction with visual performance after presbyopia-correcting IOL implantation were included in the study. A single treating physician, who determined the most probable cause of dissatisfaction, decided which interventions to pursue following the initial consultation. RESULTS: Data from 74 eyes of 49 patients were analyzed. The most common cause for complaint was blurry or foggy vision both for distance and near (68%). Complaints were most frequently attributed to residual refractive error (57%) and dry eye (35%). The most common interventions pursued were treatment of refractive error with glasses or contact lenses (46%) and treatment for dry eye (24%). Corneal laser vision correction was done in 8% of eyes; 7% required an IOL exchange. After the interventions, 45% of patients had completed resolution of symptoms, 23% of patients were partially satisfied with the results, and 32% remained completely dissatisfied with the final results. CONCLUSION: The most identifiable causes of dissatisfaction after presbyopia-correcting IOL implantation are residual refractive error and dry eye. Most patients can be managed with conservative treatment, though a significant number of patients remained unsatisfied despite multiple measures. Dove Medical Press 2016-10-11 /pmc/articles/PMC5066995/ /pubmed/27784985 http://dx.doi.org/10.2147/OPTH.S114890 Text en © 2016 Gibbons et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Gibbons, Allister Ali, Tayyeba K Waren, Daniel P Donaldson, Kendall E Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title | Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title_full | Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title_fullStr | Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title_full_unstemmed | Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title_short | Causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
title_sort | causes and correction of dissatisfaction after implantation of presbyopia-correcting intraocular lenses |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066995/ https://www.ncbi.nlm.nih.gov/pubmed/27784985 http://dx.doi.org/10.2147/OPTH.S114890 |
work_keys_str_mv | AT gibbonsallister causesandcorrectionofdissatisfactionafterimplantationofpresbyopiacorrectingintraocularlenses AT alitayyebak causesandcorrectionofdissatisfactionafterimplantationofpresbyopiacorrectingintraocularlenses AT warendanielp causesandcorrectionofdissatisfactionafterimplantationofpresbyopiacorrectingintraocularlenses AT donaldsonkendalle causesandcorrectionofdissatisfactionafterimplantationofpresbyopiacorrectingintraocularlenses |