Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study
OBJECTIVES: The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. PATIENTS AND METHODS: Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066996/ https://www.ncbi.nlm.nih.gov/pubmed/27785040 http://dx.doi.org/10.2147/TCRM.S113764 |
_version_ | 1782460578865872896 |
---|---|
author | Huang, Hairong Wismeijer, Daniel Shao, Xianhong Wu, Gang |
author_facet | Huang, Hairong Wismeijer, Daniel Shao, Xianhong Wu, Gang |
author_sort | Huang, Hairong |
collection | PubMed |
description | OBJECTIVES: The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. PATIENTS AND METHODS: Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear regression model, we analyzed the influence of the following eleven candidate factors: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting (presence or absence), insertion torque, I-/II-stage healing pattern, implant diameter, implant length, and T1–T2 time interval. RESULTS: The following factors were identified to significantly influence the implant stability quotient (ISQ) values at T1: insertion torque, bone grafting, I-/II-stage healing pattern, immediate/delayed implantation, maxillary/mandibular location, implant diameter, and sex. In contrast, the ISQ values at T2 were significantly influenced only by three factors: implant diameter, T1–T2 time interval, and insertion torque. CONCLUSION: Among the eleven candidate factors, seven key factors were found to influence the T1-ISQ values, while only three key factors influenced the T2-ISQ values. Both T1 and T2-ISQ values were found to be influenced by implant diameter and insertion torque. T1 was influenced specifically by the sex of the patient, the location (maxillary or mandibular), the implantation mode (immediate/delayed implantation), the healing stage, and the absence or presence of bone graft materials. |
format | Online Article Text |
id | pubmed-5066996 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-50669962016-10-26 Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study Huang, Hairong Wismeijer, Daniel Shao, Xianhong Wu, Gang Ther Clin Risk Manag Original Research OBJECTIVES: The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. PATIENTS AND METHODS: Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear regression model, we analyzed the influence of the following eleven candidate factors: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting (presence or absence), insertion torque, I-/II-stage healing pattern, implant diameter, implant length, and T1–T2 time interval. RESULTS: The following factors were identified to significantly influence the implant stability quotient (ISQ) values at T1: insertion torque, bone grafting, I-/II-stage healing pattern, immediate/delayed implantation, maxillary/mandibular location, implant diameter, and sex. In contrast, the ISQ values at T2 were significantly influenced only by three factors: implant diameter, T1–T2 time interval, and insertion torque. CONCLUSION: Among the eleven candidate factors, seven key factors were found to influence the T1-ISQ values, while only three key factors influenced the T2-ISQ values. Both T1 and T2-ISQ values were found to be influenced by implant diameter and insertion torque. T1 was influenced specifically by the sex of the patient, the location (maxillary or mandibular), the implantation mode (immediate/delayed implantation), the healing stage, and the absence or presence of bone graft materials. Dove Medical Press 2016-10-11 /pmc/articles/PMC5066996/ /pubmed/27785040 http://dx.doi.org/10.2147/TCRM.S113764 Text en © 2016 Huang et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Huang, Hairong Wismeijer, Daniel Shao, Xianhong Wu, Gang Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title | Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title_full | Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title_fullStr | Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title_full_unstemmed | Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title_short | Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
title_sort | mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5066996/ https://www.ncbi.nlm.nih.gov/pubmed/27785040 http://dx.doi.org/10.2147/TCRM.S113764 |
work_keys_str_mv | AT huanghairong mathematicalevaluationoftheinfluenceofmultiplefactorsonimplantstabilityquotientvaluesinclinicalpracticearetrospectivestudy AT wismeijerdaniel mathematicalevaluationoftheinfluenceofmultiplefactorsonimplantstabilityquotientvaluesinclinicalpracticearetrospectivestudy AT shaoxianhong mathematicalevaluationoftheinfluenceofmultiplefactorsonimplantstabilityquotientvaluesinclinicalpracticearetrospectivestudy AT wugang mathematicalevaluationoftheinfluenceofmultiplefactorsonimplantstabilityquotientvaluesinclinicalpracticearetrospectivestudy |