Cargando…
Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates
BACKGROUND: The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. METHODS:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5067914/ https://www.ncbi.nlm.nih.gov/pubmed/27751170 http://dx.doi.org/10.1186/s13018-016-0458-y |
_version_ | 1782460731337211904 |
---|---|
author | Ioannou, Christopher Knight, Matthew Daniele, Luca Flueckiger, Lee Tan, Ezekiel S. L. |
author_facet | Ioannou, Christopher Knight, Matthew Daniele, Luca Flueckiger, Lee Tan, Ezekiel S. L. |
author_sort | Ioannou, Christopher |
collection | PubMed |
description | BACKGROUND: The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. METHODS: Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. RESULTS: The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269–1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723–0.757). CONCLUSIONS: The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values. |
format | Online Article Text |
id | pubmed-5067914 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-50679142016-10-24 Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates Ioannou, Christopher Knight, Matthew Daniele, Luca Flueckiger, Lee Tan, Ezekiel S. L. J Orthop Surg Res Research Article BACKGROUND: The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. METHODS: Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. RESULTS: The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269–1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723–0.757). CONCLUSIONS: The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values. BioMed Central 2016-10-17 /pmc/articles/PMC5067914/ /pubmed/27751170 http://dx.doi.org/10.1186/s13018-016-0458-y Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Ioannou, Christopher Knight, Matthew Daniele, Luca Flueckiger, Lee Tan, Ezekiel S. L. Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title | Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title_full | Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title_fullStr | Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title_full_unstemmed | Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title_short | Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
title_sort | effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5067914/ https://www.ncbi.nlm.nih.gov/pubmed/27751170 http://dx.doi.org/10.1186/s13018-016-0458-y |
work_keys_str_mv | AT ioannouchristopher effectivenessofthesurgicaltorquelimiteramodelcomparingdrillandhandbasedscrewinsertionintolockingplates AT knightmatthew effectivenessofthesurgicaltorquelimiteramodelcomparingdrillandhandbasedscrewinsertionintolockingplates AT danieleluca effectivenessofthesurgicaltorquelimiteramodelcomparingdrillandhandbasedscrewinsertionintolockingplates AT flueckigerlee effectivenessofthesurgicaltorquelimiteramodelcomparingdrillandhandbasedscrewinsertionintolockingplates AT tanezekielsl effectivenessofthesurgicaltorquelimiteramodelcomparingdrillandhandbasedscrewinsertionintolockingplates |