Cargando…

100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide

The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neu...

Descripción completa

Detalles Bibliográficos
Autores principales: Trtik, Pavel, Morgano, Manuel, Bentz, Roman, Lehmann, Eberhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5067979/
https://www.ncbi.nlm.nih.gov/pubmed/27774412
http://dx.doi.org/10.1016/j.mex.2016.10.001
_version_ 1782460738596503552
author Trtik, Pavel
Morgano, Manuel
Bentz, Roman
Lehmann, Eberhard
author_facet Trtik, Pavel
Morgano, Manuel
Bentz, Roman
Lehmann, Eberhard
author_sort Trtik, Pavel
collection PubMed
description The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neutron imaging. In order to partially overcome the neutron intensity problem for the high temporal resolution imaging, a parabolic neutron focussing guide was utilized in the test arrangement and placed upstream the detector in such a manner that the focal point of the guide was positioned slightly behind the scintillator screen. In such a test arrangement, the neutron flux can be increased locally by about one order of magnitude, albeit with the reduced spatial resolution due to the increased divergence of the neutron beam. In a pilot test application, an in-situ titration system allowing for a remote delivery of well-defined volumes of liquids onto the sample stage was utilized. The process of droplets of water (H(2)O) falling into the container filled with heavy water (D(2)O) and the subsequent process of the interaction and mixing of the two liquids were imaged with temporal resolution of 0.01 s. • Combination of neutron focussing device and use of sCMOS detector allows for very high temporal resolution neutron imaging to be achieved (albeit with reduced spatial resolution and field of view). • In-situ neutron imaging titration device for liquid interaction experiments. • Interaction of otherwise indiscernible liquids (H(2)O and D(2)O) visualized using neutron radiography with 0.01 s temporal resolution.
format Online
Article
Text
id pubmed-5067979
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-50679792016-10-21 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide Trtik, Pavel Morgano, Manuel Bentz, Roman Lehmann, Eberhard MethodsX Engineering The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neutron imaging. In order to partially overcome the neutron intensity problem for the high temporal resolution imaging, a parabolic neutron focussing guide was utilized in the test arrangement and placed upstream the detector in such a manner that the focal point of the guide was positioned slightly behind the scintillator screen. In such a test arrangement, the neutron flux can be increased locally by about one order of magnitude, albeit with the reduced spatial resolution due to the increased divergence of the neutron beam. In a pilot test application, an in-situ titration system allowing for a remote delivery of well-defined volumes of liquids onto the sample stage was utilized. The process of droplets of water (H(2)O) falling into the container filled with heavy water (D(2)O) and the subsequent process of the interaction and mixing of the two liquids were imaged with temporal resolution of 0.01 s. • Combination of neutron focussing device and use of sCMOS detector allows for very high temporal resolution neutron imaging to be achieved (albeit with reduced spatial resolution and field of view). • In-situ neutron imaging titration device for liquid interaction experiments. • Interaction of otherwise indiscernible liquids (H(2)O and D(2)O) visualized using neutron radiography with 0.01 s temporal resolution. Elsevier 2016-10-06 /pmc/articles/PMC5067979/ /pubmed/27774412 http://dx.doi.org/10.1016/j.mex.2016.10.001 Text en © 2016 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Engineering
Trtik, Pavel
Morgano, Manuel
Bentz, Roman
Lehmann, Eberhard
100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title_full 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title_fullStr 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title_full_unstemmed 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title_short 100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide
title_sort 100 hz neutron radiography at the boa beamline using a parabolic focussing guide
topic Engineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5067979/
https://www.ncbi.nlm.nih.gov/pubmed/27774412
http://dx.doi.org/10.1016/j.mex.2016.10.001
work_keys_str_mv AT trtikpavel 100hzneutronradiographyattheboabeamlineusingaparabolicfocussingguide
AT morganomanuel 100hzneutronradiographyattheboabeamlineusingaparabolicfocussingguide
AT bentzroman 100hzneutronradiographyattheboabeamlineusingaparabolicfocussingguide
AT lehmanneberhard 100hzneutronradiographyattheboabeamlineusingaparabolicfocussingguide