Cargando…
Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068144/ https://www.ncbi.nlm.nih.gov/pubmed/27780513 http://dx.doi.org/10.1016/j.cjtee.2015.11.020 |
_version_ | 1782460762824900608 |
---|---|
author | Dhar, Shabir Ahmed Butt, Mohammed Farooq Dar, Tahir Ahmed Dar, Reyaz Ahmed Ali, Zameer |
author_facet | Dhar, Shabir Ahmed Butt, Mohammed Farooq Dar, Tahir Ahmed Dar, Reyaz Ahmed Ali, Zameer |
author_sort | Dhar, Shabir Ahmed |
collection | PubMed |
description | Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The challenge is further compounded in severe osteoporosis when the cortical thickness is affected more severely. We used a combination of an intramedullary fibula with a locking plate in 5 cases. The results show that it may be a good combination in such situations as the bone strength is augmented and the plate pullout is less likely. |
format | Online Article Text |
id | pubmed-5068144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-50681442016-11-07 Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting Dhar, Shabir Ahmed Butt, Mohammed Farooq Dar, Tahir Ahmed Dar, Reyaz Ahmed Ali, Zameer Chin J Traumatol Case Report Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The challenge is further compounded in severe osteoporosis when the cortical thickness is affected more severely. We used a combination of an intramedullary fibula with a locking plate in 5 cases. The results show that it may be a good combination in such situations as the bone strength is augmented and the plate pullout is less likely. Elsevier 2016-10-13 2016-05-13 /pmc/articles/PMC5068144/ /pubmed/27780513 http://dx.doi.org/10.1016/j.cjtee.2015.11.020 Text en © 2016 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Dhar, Shabir Ahmed Butt, Mohammed Farooq Dar, Tahir Ahmed Dar, Reyaz Ahmed Ali, Zameer Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title | Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title_full | Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title_fullStr | Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title_full_unstemmed | Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title_short | Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
title_sort | management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068144/ https://www.ncbi.nlm.nih.gov/pubmed/27780513 http://dx.doi.org/10.1016/j.cjtee.2015.11.020 |
work_keys_str_mv | AT dharshabirahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting AT buttmohammedfarooq managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting AT dartahirahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting AT darreyazahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting AT alizameer managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting |