Cargando…

Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting

Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhar, Shabir Ahmed, Butt, Mohammed Farooq, Dar, Tahir Ahmed, Dar, Reyaz Ahmed, Ali, Zameer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068144/
https://www.ncbi.nlm.nih.gov/pubmed/27780513
http://dx.doi.org/10.1016/j.cjtee.2015.11.020
_version_ 1782460762824900608
author Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Dar, Tahir Ahmed
Dar, Reyaz Ahmed
Ali, Zameer
author_facet Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Dar, Tahir Ahmed
Dar, Reyaz Ahmed
Ali, Zameer
author_sort Dhar, Shabir Ahmed
collection PubMed
description Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The challenge is further compounded in severe osteoporosis when the cortical thickness is affected more severely. We used a combination of an intramedullary fibula with a locking plate in 5 cases. The results show that it may be a good combination in such situations as the bone strength is augmented and the plate pullout is less likely.
format Online
Article
Text
id pubmed-5068144
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-50681442016-11-07 Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting Dhar, Shabir Ahmed Butt, Mohammed Farooq Dar, Tahir Ahmed Dar, Reyaz Ahmed Ali, Zameer Chin J Traumatol Case Report Nonunion of the humerus in a severely osteoporotic bone is a likely event especially if the fracture is transverse. The management of such a combination is a challenge. Most of the conventional fixation methods are unlikely to succeed as the bone failure precedes implant failure in osteoporosis. The challenge is further compounded in severe osteoporosis when the cortical thickness is affected more severely. We used a combination of an intramedullary fibula with a locking plate in 5 cases. The results show that it may be a good combination in such situations as the bone strength is augmented and the plate pullout is less likely. Elsevier 2016-10-13 2016-05-13 /pmc/articles/PMC5068144/ /pubmed/27780513 http://dx.doi.org/10.1016/j.cjtee.2015.11.020 Text en © 2016 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Dar, Tahir Ahmed
Dar, Reyaz Ahmed
Ali, Zameer
Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title_full Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title_fullStr Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title_full_unstemmed Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title_short Management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
title_sort management of humeral fracture nonunion in severe osteoporosis by a combination of locking plating and intramedullary fibular grafting
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068144/
https://www.ncbi.nlm.nih.gov/pubmed/27780513
http://dx.doi.org/10.1016/j.cjtee.2015.11.020
work_keys_str_mv AT dharshabirahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting
AT buttmohammedfarooq managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting
AT dartahirahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting
AT darreyazahmed managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting
AT alizameer managementofhumeralfracturenonunioninsevereosteoporosisbyacombinationoflockingplatingandintramedullaryfibulargrafting