Cargando…

Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics

BACKGROUND: Graft reperfusion poses a critical challenge during liver transplantation and can be associated with hemodynamic instability/postreperfusion syndrome. This is sequel to ischemia-reperfusion injury and normothermic machine preservation (NMP) may affect hemodynamic changes. Herein, we char...

Descripción completa

Detalles Bibliográficos
Autores principales: Angelico, Roberta, Perera, M. Thamara P. R, Ravikumar, Reena, Holroyd, David, Coussios, Constantin, Mergental, Hynek, Isaac, John R., Iqbal, Asim, Cilliers, Hentie, Muiesan, Paolo, Friend, Peter J., Mirza, Darius F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068202/
https://www.ncbi.nlm.nih.gov/pubmed/27795989
http://dx.doi.org/10.1097/TXD.0000000000000611
_version_ 1782460769641693184
author Angelico, Roberta
Perera, M. Thamara P. R
Ravikumar, Reena
Holroyd, David
Coussios, Constantin
Mergental, Hynek
Isaac, John R.
Iqbal, Asim
Cilliers, Hentie
Muiesan, Paolo
Friend, Peter J.
Mirza, Darius F.
author_facet Angelico, Roberta
Perera, M. Thamara P. R
Ravikumar, Reena
Holroyd, David
Coussios, Constantin
Mergental, Hynek
Isaac, John R.
Iqbal, Asim
Cilliers, Hentie
Muiesan, Paolo
Friend, Peter J.
Mirza, Darius F.
author_sort Angelico, Roberta
collection PubMed
description BACKGROUND: Graft reperfusion poses a critical challenge during liver transplantation and can be associated with hemodynamic instability/postreperfusion syndrome. This is sequel to ischemia-reperfusion injury and normothermic machine preservation (NMP) may affect hemodynamic changes. Herein, we characterize postreperfusion hemodynamics in liver grafts after NMP and traditional cold preservation. MATERIALS AND METHODS: Intraoperative records of patients receiving grafts after NMP (n = 6; NMP group) and cold storage (CS) (n = 12; CS group) were compared. The mean arterial pressure (MAP) was defined as the average pressure in the radial artery during 1 cardiac cycle by invasive monitoring. Postreperfusion syndrome was defined as MAP drop greater than 30% of baseline, lasting for 1 minute or longer within the first 5 minutes from graft reperfusion. RESULTS: Donor, recipient, demographics, and surgical parameters were evenly matched. Normothermic machine preservation grafts were perfused for 525 minutes (395-605 minutes) after initial cold ischemic time of 91 minutes (73-117 minutes), whereas in CS group cold ischemic time was 456 minutes (347-685 minutes) (P = 0.001). None developed postreperfusion syndrome in the NMP group against n = 2 (16.7%) in CS group (P = 0.529). Normothermic machine preservation group had better intraoperative MAP at 90 minutes postreperfusion (P = 0.029), achieved with a significantly less vasopressor requirement (P = <0.05) and less transfusion of blood products (P = 0.030) compared with CS group. CONCLUSIONS: Normothermic machine perfusion is associated with a stable intraoperative hemodynamic profile postreperfusion, requiring significantly less vasopressor infusions and blood product transfusion after graft reperfusion and may have benefit to alleviate ischemia-reperfusion injury in liver transplantation.
format Online
Article
Text
id pubmed-5068202
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-50682022017-03-27 Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics Angelico, Roberta Perera, M. Thamara P. R Ravikumar, Reena Holroyd, David Coussios, Constantin Mergental, Hynek Isaac, John R. Iqbal, Asim Cilliers, Hentie Muiesan, Paolo Friend, Peter J. Mirza, Darius F. Transplant Direct Liver Transplantation BACKGROUND: Graft reperfusion poses a critical challenge during liver transplantation and can be associated with hemodynamic instability/postreperfusion syndrome. This is sequel to ischemia-reperfusion injury and normothermic machine preservation (NMP) may affect hemodynamic changes. Herein, we characterize postreperfusion hemodynamics in liver grafts after NMP and traditional cold preservation. MATERIALS AND METHODS: Intraoperative records of patients receiving grafts after NMP (n = 6; NMP group) and cold storage (CS) (n = 12; CS group) were compared. The mean arterial pressure (MAP) was defined as the average pressure in the radial artery during 1 cardiac cycle by invasive monitoring. Postreperfusion syndrome was defined as MAP drop greater than 30% of baseline, lasting for 1 minute or longer within the first 5 minutes from graft reperfusion. RESULTS: Donor, recipient, demographics, and surgical parameters were evenly matched. Normothermic machine preservation grafts were perfused for 525 minutes (395-605 minutes) after initial cold ischemic time of 91 minutes (73-117 minutes), whereas in CS group cold ischemic time was 456 minutes (347-685 minutes) (P = 0.001). None developed postreperfusion syndrome in the NMP group against n = 2 (16.7%) in CS group (P = 0.529). Normothermic machine preservation group had better intraoperative MAP at 90 minutes postreperfusion (P = 0.029), achieved with a significantly less vasopressor requirement (P = <0.05) and less transfusion of blood products (P = 0.030) compared with CS group. CONCLUSIONS: Normothermic machine perfusion is associated with a stable intraoperative hemodynamic profile postreperfusion, requiring significantly less vasopressor infusions and blood product transfusion after graft reperfusion and may have benefit to alleviate ischemia-reperfusion injury in liver transplantation. Lippincott Williams & Wilkins 2016-08-05 /pmc/articles/PMC5068202/ /pubmed/27795989 http://dx.doi.org/10.1097/TXD.0000000000000611 Text en Copyright © 2016 The Authors. Transplantation Direct. Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.
spellingShingle Liver Transplantation
Angelico, Roberta
Perera, M. Thamara P. R
Ravikumar, Reena
Holroyd, David
Coussios, Constantin
Mergental, Hynek
Isaac, John R.
Iqbal, Asim
Cilliers, Hentie
Muiesan, Paolo
Friend, Peter J.
Mirza, Darius F.
Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title_full Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title_fullStr Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title_full_unstemmed Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title_short Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics
title_sort normothermic machine perfusion of deceased donor liver grafts is associated with improved postreperfusion hemodynamics
topic Liver Transplantation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5068202/
https://www.ncbi.nlm.nih.gov/pubmed/27795989
http://dx.doi.org/10.1097/TXD.0000000000000611
work_keys_str_mv AT angelicoroberta normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT pereramthamarapr normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT ravikumarreena normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT holroyddavid normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT coussiosconstantin normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT mergentalhynek normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT isaacjohnr normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT iqbalasim normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT cilliershentie normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT muiesanpaolo normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT friendpeterj normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics
AT mirzadariusf normothermicmachineperfusionofdeceaseddonorlivergraftsisassociatedwithimprovedpostreperfusionhemodynamics