Cargando…
Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2
BACKGROUND: Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis. The American College of Radiology revised the PI-RADS to address the limitations of version 1 in Decem...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5072258/ https://www.ncbi.nlm.nih.gov/pubmed/27748338 http://dx.doi.org/10.4103/0366-6999.191771 |
_version_ | 1782461374784339968 |
---|---|
author | Feng, Zhao-Yan Wang, Liang Min, Xiang-De Wang, Shao-Gang Wang, Guo-Ping Cai, Jie |
author_facet | Feng, Zhao-Yan Wang, Liang Min, Xiang-De Wang, Shao-Gang Wang, Guo-Ping Cai, Jie |
author_sort | Feng, Zhao-Yan |
collection | PubMed |
description | BACKGROUND: Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis. The American College of Radiology revised the PI-RADS to address the limitations of version 1 in December 2014. This study aimed to determine whether the PI-RADS version 2 (PI-RADS v2) scoring system improves the diagnostic accuracy of mp-MRI of the prostate compared with PI-RADS v1. METHODS: This retrospective study was approved by the institutional review board. A total of 401 consecutive patients, with clinically suspicious PCa undergoing 3.0 T mp-MRI (T2-weighted imaging + diffusion-weighted imaging + DCE) before transrectal ultrasound-guided biopsy between June 2013 and July 2015, were included in the study. All patients were scored using the 5-point PI-RADS scoring system based on either PI-RADS v1 or v2. Receiver operating characteristics were calculated for statistical analysis. Sensitivity, specificity, and diagnostic accuracy were compared using McNemar's test. RESULTS: PCa was present in 150 of 401 (37.41%) patients. When we pooled data from both peripheral zone (PZ) and transition zone (TZ), the areas under the curve were 0.889 for PI-RADS v1 and 0.942 for v2 (P = 0.0001). Maximal accuracy was achieved with a score threshold of 4. At this threshold, in the PZ, similar sensitivity, specificity, and accuracy were achieved with v1 and v2 (all P > 0.05). In the TZ, sensitivity was higher for v2 than for v1 (96.36% vs. 76.36%, P = 0.003), specificity was similar for v2 and v1 (90.24% vs. 84.15%, P = 0.227), and accuracy was higher for v2 than for v1 (92.70% vs. 81.02%, P = 0.002). CONCLUSIONS: Both v1 and v2 showed good diagnostic performance for the detection of PCa. However, in the TZ, the performance was better with v2 than with v1. |
format | Online Article Text |
id | pubmed-5072258 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-50722582016-11-01 Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 Feng, Zhao-Yan Wang, Liang Min, Xiang-De Wang, Shao-Gang Wang, Guo-Ping Cai, Jie Chin Med J (Engl) Original Article BACKGROUND: Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis. The American College of Radiology revised the PI-RADS to address the limitations of version 1 in December 2014. This study aimed to determine whether the PI-RADS version 2 (PI-RADS v2) scoring system improves the diagnostic accuracy of mp-MRI of the prostate compared with PI-RADS v1. METHODS: This retrospective study was approved by the institutional review board. A total of 401 consecutive patients, with clinically suspicious PCa undergoing 3.0 T mp-MRI (T2-weighted imaging + diffusion-weighted imaging + DCE) before transrectal ultrasound-guided biopsy between June 2013 and July 2015, were included in the study. All patients were scored using the 5-point PI-RADS scoring system based on either PI-RADS v1 or v2. Receiver operating characteristics were calculated for statistical analysis. Sensitivity, specificity, and diagnostic accuracy were compared using McNemar's test. RESULTS: PCa was present in 150 of 401 (37.41%) patients. When we pooled data from both peripheral zone (PZ) and transition zone (TZ), the areas under the curve were 0.889 for PI-RADS v1 and 0.942 for v2 (P = 0.0001). Maximal accuracy was achieved with a score threshold of 4. At this threshold, in the PZ, similar sensitivity, specificity, and accuracy were achieved with v1 and v2 (all P > 0.05). In the TZ, sensitivity was higher for v2 than for v1 (96.36% vs. 76.36%, P = 0.003), specificity was similar for v2 and v1 (90.24% vs. 84.15%, P = 0.227), and accuracy was higher for v2 than for v1 (92.70% vs. 81.02%, P = 0.002). CONCLUSIONS: Both v1 and v2 showed good diagnostic performance for the detection of PCa. However, in the TZ, the performance was better with v2 than with v1. Medknow Publications & Media Pvt Ltd 2016-10-20 /pmc/articles/PMC5072258/ /pubmed/27748338 http://dx.doi.org/10.4103/0366-6999.191771 Text en Copyright: © 2016 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Feng, Zhao-Yan Wang, Liang Min, Xiang-De Wang, Shao-Gang Wang, Guo-Ping Cai, Jie Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title | Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title_full | Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title_fullStr | Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title_full_unstemmed | Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title_short | Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 |
title_sort | prostate cancer detection with multiparametric magnetic resonance imaging: prostate imaging reporting and data system version 1 versus version 2 |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5072258/ https://www.ncbi.nlm.nih.gov/pubmed/27748338 http://dx.doi.org/10.4103/0366-6999.191771 |
work_keys_str_mv | AT fengzhaoyan prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 AT wangliang prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 AT minxiangde prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 AT wangshaogang prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 AT wangguoping prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 AT caijie prostatecancerdetectionwithmultiparametricmagneticresonanceimagingprostateimagingreportinganddatasystemversion1versusversion2 |