Cargando…

Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro

BACKGROUND: A single drilled tunnel from the lateral mastoid cortex to the cochlea via the facial recess is essential for minimally invasive cochlear implant surgery. This study aimed to explore the safety profile of this kind of new image-guided and bi-planar device-assisted surgery procedure in vi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ke, Jia, Zhang, Shao-Xing, Hu, Lei, Li, Chang-Sheng, Zhu, Yun-Feng, Sun, Shi-Long, Wang, Li-Feng, Ma, Fu-Rong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5072261/
https://www.ncbi.nlm.nih.gov/pubmed/27748341
http://dx.doi.org/10.4103/0366-6999.191787
_version_ 1782461375495274496
author Ke, Jia
Zhang, Shao-Xing
Hu, Lei
Li, Chang-Sheng
Zhu, Yun-Feng
Sun, Shi-Long
Wang, Li-Feng
Ma, Fu-Rong
author_facet Ke, Jia
Zhang, Shao-Xing
Hu, Lei
Li, Chang-Sheng
Zhu, Yun-Feng
Sun, Shi-Long
Wang, Li-Feng
Ma, Fu-Rong
author_sort Ke, Jia
collection PubMed
description BACKGROUND: A single drilled tunnel from the lateral mastoid cortex to the cochlea via the facial recess is essential for minimally invasive cochlear implant surgery. This study aimed to explore the safety profile of this kind of new image-guided and bi-planar device-assisted surgery procedure in vitro. METHODS: Image-guided minimally invasive cochlear implantations were performed on eight cadaveric temporal bone specimens. The main procedures were: (1) temporal bone specimens were prepared for surgery and fiducial markers were registered. (2) computed tomography (CT) scans were performed for future reference. (3) CT scan images were processed and drill path was planned to minimize cochlear damage. (4) bi-planar device-assisted drilling was performed on the specimens using the registration. (5) surgical safety was evaluated by calculating the deviation between the drill and the planned paths, and by measuring the closest distance between the drilled path and critical anatomic structures. RESULTS: Eight cases were operated successfully to the basal turn of the cochlear with intact facial nerves (FNs). The deviations from target points and entrance points were 0.86 mm (0.68–1.00 mm) and 0.44 mm (0.30–0.96 mm), respectively. The angular error between the planned and the drilled trajectory was 1.74° (1.26–2.41°). The mean distance from the edge of the drilled path to the FN and to the external canal was 0.60 mm (0.35–0.83 mm) and 1.60 mm (1.30–2.05 mm), respectively. In five specimens, the chorda tympani nerves were well preserved. In all cases, no injury happened to auditory ossicles. CONCLUSIONS: This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety.
format Online
Article
Text
id pubmed-5072261
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-50722612016-11-01 Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro Ke, Jia Zhang, Shao-Xing Hu, Lei Li, Chang-Sheng Zhu, Yun-Feng Sun, Shi-Long Wang, Li-Feng Ma, Fu-Rong Chin Med J (Engl) Original Article BACKGROUND: A single drilled tunnel from the lateral mastoid cortex to the cochlea via the facial recess is essential for minimally invasive cochlear implant surgery. This study aimed to explore the safety profile of this kind of new image-guided and bi-planar device-assisted surgery procedure in vitro. METHODS: Image-guided minimally invasive cochlear implantations were performed on eight cadaveric temporal bone specimens. The main procedures were: (1) temporal bone specimens were prepared for surgery and fiducial markers were registered. (2) computed tomography (CT) scans were performed for future reference. (3) CT scan images were processed and drill path was planned to minimize cochlear damage. (4) bi-planar device-assisted drilling was performed on the specimens using the registration. (5) surgical safety was evaluated by calculating the deviation between the drill and the planned paths, and by measuring the closest distance between the drilled path and critical anatomic structures. RESULTS: Eight cases were operated successfully to the basal turn of the cochlear with intact facial nerves (FNs). The deviations from target points and entrance points were 0.86 mm (0.68–1.00 mm) and 0.44 mm (0.30–0.96 mm), respectively. The angular error between the planned and the drilled trajectory was 1.74° (1.26–2.41°). The mean distance from the edge of the drilled path to the FN and to the external canal was 0.60 mm (0.35–0.83 mm) and 1.60 mm (1.30–2.05 mm), respectively. In five specimens, the chorda tympani nerves were well preserved. In all cases, no injury happened to auditory ossicles. CONCLUSIONS: This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety. Medknow Publications & Media Pvt Ltd 2016-10-20 /pmc/articles/PMC5072261/ /pubmed/27748341 http://dx.doi.org/10.4103/0366-6999.191787 Text en Copyright: © 2016 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ke, Jia
Zhang, Shao-Xing
Hu, Lei
Li, Chang-Sheng
Zhu, Yun-Feng
Sun, Shi-Long
Wang, Li-Feng
Ma, Fu-Rong
Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title_full Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title_fullStr Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title_full_unstemmed Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title_short Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro
title_sort minimally invasive cochlear implantation assisted by bi-planar device: an exploratory feasibility study in vitro
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5072261/
https://www.ncbi.nlm.nih.gov/pubmed/27748341
http://dx.doi.org/10.4103/0366-6999.191787
work_keys_str_mv AT kejia minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT zhangshaoxing minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT hulei minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT lichangsheng minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT zhuyunfeng minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT sunshilong minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT wanglifeng minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro
AT mafurong minimallyinvasivecochlearimplantationassistedbybiplanardeviceanexploratoryfeasibilitystudyinvitro