Cargando…
Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study
OBJECTIVE: (1) To evaluate the corrosion resistance of four different orthodontic archwires and to determine the effect of 0.5% NaF (simulating high fluoride-containing toothpaste of about 2250 ppm) on corrosion resistance of these archwires. (2) To assess whether surface roughness (Ra) is the prima...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5074051/ https://www.ncbi.nlm.nih.gov/pubmed/27829756 http://dx.doi.org/10.4103/0975-7406.192032 |
_version_ | 1782461688358895616 |
---|---|
author | Pulikkottil, Venith Jojee Chidambaram, S. Bejoy, P. U. Femin, P. K. Paul, Parson Rishad, Mohamed |
author_facet | Pulikkottil, Venith Jojee Chidambaram, S. Bejoy, P. U. Femin, P. K. Paul, Parson Rishad, Mohamed |
author_sort | Pulikkottil, Venith Jojee |
collection | PubMed |
description | OBJECTIVE: (1) To evaluate the corrosion resistance of four different orthodontic archwires and to determine the effect of 0.5% NaF (simulating high fluoride-containing toothpaste of about 2250 ppm) on corrosion resistance of these archwires. (2) To assess whether surface roughness (Ra) is the primary factor influencing the corrosion resistance of these archwires. MATERIALS AND METHODS: Four different archwires (stainless steel [SS], nickel-titanium [NiTi], titanium molybdenum alloy [TMA], and ion-implanted TMA) were considered for this study. Surface characteristics were analyzed using scanning electron microscopy, atomic force microscopy (AFM), and energy dispersive spectroscopy. Linear polarization test, a fast electrochemical technique, was used to evaluate the corrosion resistance, in terms of polarization resistance of four different archwires in artificial saliva with NaF concentrations of 0% and 0.5%. Statistical analysis was performed by one-way analysis of variance. RESULTS: The potentiostatic study reveals that the corrosion resistance of low-friction TMA (L-TMA) > TMA > NiTi > SS. AFM analysis showed the surface Ra of TMA > NiTi > L-TMA > SS. This indicates that the chemical composition of the wire is the primary influential factor to have high corrosion resistance and surface Ra is only secondary. The corrosion resistance of all wires had reduced significantly in 0.5% acidic fluoride-containing artificial saliva due to formation of fluoride complex compound. CONCLUSION: The presence of 0.5% NaF in artificial saliva was detrimental to the corrosion resistance of the orthodontic archwires. Therefore, complete removal of residual high-fluorinated toothpastes from the crevice between archwire and bracket during tooth brushing is mandatory. |
format | Online Article Text |
id | pubmed-5074051 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-50740512016-11-09 Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study Pulikkottil, Venith Jojee Chidambaram, S. Bejoy, P. U. Femin, P. K. Paul, Parson Rishad, Mohamed J Pharm Bioallied Sci Original Research Article OBJECTIVE: (1) To evaluate the corrosion resistance of four different orthodontic archwires and to determine the effect of 0.5% NaF (simulating high fluoride-containing toothpaste of about 2250 ppm) on corrosion resistance of these archwires. (2) To assess whether surface roughness (Ra) is the primary factor influencing the corrosion resistance of these archwires. MATERIALS AND METHODS: Four different archwires (stainless steel [SS], nickel-titanium [NiTi], titanium molybdenum alloy [TMA], and ion-implanted TMA) were considered for this study. Surface characteristics were analyzed using scanning electron microscopy, atomic force microscopy (AFM), and energy dispersive spectroscopy. Linear polarization test, a fast electrochemical technique, was used to evaluate the corrosion resistance, in terms of polarization resistance of four different archwires in artificial saliva with NaF concentrations of 0% and 0.5%. Statistical analysis was performed by one-way analysis of variance. RESULTS: The potentiostatic study reveals that the corrosion resistance of low-friction TMA (L-TMA) > TMA > NiTi > SS. AFM analysis showed the surface Ra of TMA > NiTi > L-TMA > SS. This indicates that the chemical composition of the wire is the primary influential factor to have high corrosion resistance and surface Ra is only secondary. The corrosion resistance of all wires had reduced significantly in 0.5% acidic fluoride-containing artificial saliva due to formation of fluoride complex compound. CONCLUSION: The presence of 0.5% NaF in artificial saliva was detrimental to the corrosion resistance of the orthodontic archwires. Therefore, complete removal of residual high-fluorinated toothpastes from the crevice between archwire and bracket during tooth brushing is mandatory. Medknow Publications & Media Pvt Ltd 2016-10 /pmc/articles/PMC5074051/ /pubmed/27829756 http://dx.doi.org/10.4103/0975-7406.192032 Text en Copyright: © Journal of Pharmacy And Bioallied Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Research Article Pulikkottil, Venith Jojee Chidambaram, S. Bejoy, P. U. Femin, P. K. Paul, Parson Rishad, Mohamed Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title | Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title_full | Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title_fullStr | Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title_full_unstemmed | Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title_short | Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study |
title_sort | corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: an in vitro study |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5074051/ https://www.ncbi.nlm.nih.gov/pubmed/27829756 http://dx.doi.org/10.4103/0975-7406.192032 |
work_keys_str_mv | AT pulikkottilvenithjojee corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy AT chidambarams corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy AT bejoypu corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy AT feminpk corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy AT paulparson corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy AT rishadmohamed corrosionresistanceofstainlesssteelnickeltitaniumtitaniummolybdenumalloyandionimplantedtitaniummolybdenumalloyarchwiresinacidicfluoridecontainingartificialsalivaaninvitrostudy |