Cargando…
Slow-pull and different conventional suction techniques in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid lesions using 22-gauge needles
AIM: To evaluate the cytological diagnostic capacity and sample quality of the slow-pull technique and compare them with different suction techniques. METHODS: From July 2010 to December 2015, 102 patients with pancreatic solid lesions who underwent endoscopic ultrasound-guided fine-needle aspiratio...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5075553/ https://www.ncbi.nlm.nih.gov/pubmed/27818594 http://dx.doi.org/10.3748/wjg.v22.i39.8790 |
Sumario: | AIM: To evaluate the cytological diagnostic capacity and sample quality of the slow-pull technique and compare them with different suction techniques. METHODS: From July 2010 to December 2015, 102 patients with pancreatic solid lesions who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) with 22-gauge needles were retrospectively evaluated. EUS-FNA diagnosis was based on a cytological examination, and final diagnosis was based on a comprehensive standard of cytological diagnosis, surgical pathology and clinical or imaging follow-up. Cytological specimens were characterized for cellularity and blood contamination. The cytological diagnostic capacity and sample quality of the slow-pull technique and suction techniques with 5-mL/10-mL/20-mL syringes were analyzed. RESULTS: Of all of the EUS-FNA procedures, the slow-pull technique and suction techniques with 5-mL/10-mL/20-mL syringes were used in 31, 19, 34 and 18 procedures, respectively. There were significant differences between these four suction techniques in terms of cytological diagnostic accuracy (90.3% vs 63.2% vs 58.8% vs 55.6%, P = 0.019), sensitivity (88.2% vs 41.7% vs 40.0% vs 36.4%, P = 0.009) and blood contamination (score ≥ 2 for 29.0% vs 52.6% vs 70.6% vs 72.2%, P = 0.003). The accuracy and sensitivity of the slow-pull technique were significantly higher than those of the suction techniques using 5-mL (P = 0.03, P = 0.014), 10-mL (P = 0.005; P = 0.006) and 20-mL syringes (P = 0.01, P = 0.01). Blood contamination was significantly lower in the slow-pull technique than in the suction techniques with 10-mL (P = 0.001) and 20-mL syringes (P = 0.007). CONCLUSION: The slow-pull technique may increase the cytological diagnostic accuracy and sensitivity with slight blood contamination during EUS-FNA when using 22-gauge needles for solid pancreatic masses. |
---|