Cargando…
Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory
Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082210/ https://www.ncbi.nlm.nih.gov/pubmed/27812305 http://dx.doi.org/10.11613/BM.2016.040 |
_version_ | 1782463012731355136 |
---|---|
author | Bakan, Ebubekir Ozturk, Nurinnisa Baygutalp, Nurcan Kilic Polat, Elif Akpinar, Kadriye Dorman, Emrullah Polat, Harun Bakan, Nuri |
author_facet | Bakan, Ebubekir Ozturk, Nurinnisa Baygutalp, Nurcan Kilic Polat, Elif Akpinar, Kadriye Dorman, Emrullah Polat, Harun Bakan, Nuri |
author_sort | Bakan, Ebubekir |
collection | PubMed |
description | INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. RESULTS: The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. CONCLUSIONS: The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. |
format | Online Article Text |
id | pubmed-5082210 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Croatian Society of Medical Biochemistry and Laboratory
Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-50822102016-11-03 Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy Bakan, Ebubekir Ozturk, Nurinnisa Baygutalp, Nurcan Kilic Polat, Elif Akpinar, Kadriye Dorman, Emrullah Polat, Harun Bakan, Nuri Biochem Med (Zagreb) Original Papers INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. RESULTS: The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. CONCLUSIONS: The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. Croatian Society of Medical Biochemistry and Laboratory Medicine 2016-10-15 2016-10-15 /pmc/articles/PMC5082210/ /pubmed/27812305 http://dx.doi.org/10.11613/BM.2016.040 Text en |
spellingShingle | Original Papers Bakan, Ebubekir Ozturk, Nurinnisa Baygutalp, Nurcan Kilic Polat, Elif Akpinar, Kadriye Dorman, Emrullah Polat, Harun Bakan, Nuri Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy |
title | Comparison of Cobas 6500 and Iris IQ200 fully-automated urine
analyzers to manual urine microscopy |
title_full | Comparison of Cobas 6500 and Iris IQ200 fully-automated urine
analyzers to manual urine microscopy |
title_fullStr | Comparison of Cobas 6500 and Iris IQ200 fully-automated urine
analyzers to manual urine microscopy |
title_full_unstemmed | Comparison of Cobas 6500 and Iris IQ200 fully-automated urine
analyzers to manual urine microscopy |
title_short | Comparison of Cobas 6500 and Iris IQ200 fully-automated urine
analyzers to manual urine microscopy |
title_sort | comparison of cobas 6500 and iris iq200 fully-automated urine
analyzers to manual urine microscopy |
topic | Original Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082210/ https://www.ncbi.nlm.nih.gov/pubmed/27812305 http://dx.doi.org/10.11613/BM.2016.040 |
work_keys_str_mv | AT bakanebubekir comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT ozturknurinnisa comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT baygutalpnurcankilic comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT polatelif comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT akpinarkadriye comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT dormanemrullah comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT polatharun comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy AT bakannuri comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy |