Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy

INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakan, Ebubekir, Ozturk, Nurinnisa, Baygutalp, Nurcan Kilic, Polat, Elif, Akpinar, Kadriye, Dorman, Emrullah, Polat, Harun, Bakan, Nuri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082210/
https://www.ncbi.nlm.nih.gov/pubmed/27812305
http://dx.doi.org/10.11613/BM.2016.040
_version_ 1782463012731355136
author Bakan, Ebubekir
Ozturk, Nurinnisa
Baygutalp, Nurcan Kilic
Polat, Elif
Akpinar, Kadriye
Dorman, Emrullah
Polat, Harun
Bakan, Nuri
author_facet Bakan, Ebubekir
Ozturk, Nurinnisa
Baygutalp, Nurcan Kilic
Polat, Elif
Akpinar, Kadriye
Dorman, Emrullah
Polat, Harun
Bakan, Nuri
author_sort Bakan, Ebubekir
collection PubMed
description INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. RESULTS: The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. CONCLUSIONS: The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful.
format Online
Article
Text
id pubmed-5082210
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-50822102016-11-03 Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy Bakan, Ebubekir Ozturk, Nurinnisa Baygutalp, Nurcan Kilic Polat, Elif Akpinar, Kadriye Dorman, Emrullah Polat, Harun Bakan, Nuri Biochem Med (Zagreb) Original Papers INTRODUCTION: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS: A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. RESULTS: The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. CONCLUSIONS: The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. Croatian Society of Medical Biochemistry and Laboratory Medicine 2016-10-15 2016-10-15 /pmc/articles/PMC5082210/ /pubmed/27812305 http://dx.doi.org/10.11613/BM.2016.040 Text en
spellingShingle Original Papers
Bakan, Ebubekir
Ozturk, Nurinnisa
Baygutalp, Nurcan Kilic
Polat, Elif
Akpinar, Kadriye
Dorman, Emrullah
Polat, Harun
Bakan, Nuri
Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title_full Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title_fullStr Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title_full_unstemmed Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title_short Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
title_sort comparison of cobas 6500 and iris iq200 fully-automated urine analyzers to manual urine microscopy
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082210/
https://www.ncbi.nlm.nih.gov/pubmed/27812305
http://dx.doi.org/10.11613/BM.2016.040
work_keys_str_mv AT bakanebubekir comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT ozturknurinnisa comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT baygutalpnurcankilic comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT polatelif comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT akpinarkadriye comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT dormanemrullah comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT polatharun comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy
AT bakannuri comparisonofcobas6500andirisiq200fullyautomatedurineanalyzerstomanualurinemicroscopy