Cargando…

A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination

INTRODUCTION: Haemoglobin A(1c) (HbA(1c)) is widely used in the management of diabetes. Therefore, the reliability and comparability among different analytical methods for its detection have become very important. MATERIALS AND METHODS: A comparative evaluation of the analytical performances (precis...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Xiaobin, Chao, Yan, Wan, Zemin, Wang, Yunxiu, Ma, Yan, Ke, Peifeng, Wu, Xinzhong, Xu, Jianhua, Zhuang, Junhua, Huang, Xianzhang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082223/
https://www.ncbi.nlm.nih.gov/pubmed/27812304
http://dx.doi.org/10.11613/BM.2016.039
_version_ 1782463015908540416
author Wu, Xiaobin
Chao, Yan
Wan, Zemin
Wang, Yunxiu
Ma, Yan
Ke, Peifeng
Wu, Xinzhong
Xu, Jianhua
Zhuang, Junhua
Huang, Xianzhang
author_facet Wu, Xiaobin
Chao, Yan
Wan, Zemin
Wang, Yunxiu
Ma, Yan
Ke, Peifeng
Wu, Xinzhong
Xu, Jianhua
Zhuang, Junhua
Huang, Xianzhang
author_sort Wu, Xiaobin
collection PubMed
description INTRODUCTION: Haemoglobin A(1c) (HbA(1c)) is widely used in the management of diabetes. Therefore, the reliability and comparability among different analytical methods for its detection have become very important. MATERIALS AND METHODS: A comparative evaluation of the analytical performances (precision, linearity, accuracy, method comparison, and interferences including bilirubin, triglyceride, cholesterol, labile HbA(1c) (LA(1c)), vitamin C, aspirin, fetal haemoglobin (HbF), and haemoglobin E (Hb E)) were performed on Capillarys 2 Flex Piercing (Capillarys 2FP) (Sebia, France), Tosoh HLC-723 G8 (Tosoh G8) (Tosoh, Japan), Premier Hb9210 (Trinity Biotech, Ireland) and Roche Cobas c501 (Roche c501) (Roche Diagnostics, Germany). RESULTS: A good precision was shown at both low and high HbA(1c) levels on all four systems, with all individual CVs below 2% (IFCC units) or 1.5% (NGSP units). Linearity analysis for each analyzer had achieved a good correlation coefficient (R(2) > 0.99) over the entire range tested. The analytical bias of the four systems against the IFCC targets was less than ± 6% (NGSP units), indicating a good accuracy. Method comparison showed a great correlation and agreement between methods. Very high levels of triglycerides and cholesterol (≥ 15.28 and ≥ 8.72 mmol/L, respectively) led to falsely low HbA(1c) concentrations on Roche c501. Elevated HbF induced false HbA(1c) detection on Capillarys 2FP (> 10%), Tosoh G8 (> 30%), Premier Hb9210 (> 15%), and Roche c501 (> 5%). On Tosoh G8, HbE induced an extra peak on chromatogram, and significantly lower results were reported. CONCLUSIONS: The four HbA(1c) methods commonly used with commercial analyzers showed a good reliability and comparability, although some interference may falsely alter the result.
format Online
Article
Text
id pubmed-5082223
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-50822232016-11-03 A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination Wu, Xiaobin Chao, Yan Wan, Zemin Wang, Yunxiu Ma, Yan Ke, Peifeng Wu, Xinzhong Xu, Jianhua Zhuang, Junhua Huang, Xianzhang Biochem Med (Zagreb) Original Papers INTRODUCTION: Haemoglobin A(1c) (HbA(1c)) is widely used in the management of diabetes. Therefore, the reliability and comparability among different analytical methods for its detection have become very important. MATERIALS AND METHODS: A comparative evaluation of the analytical performances (precision, linearity, accuracy, method comparison, and interferences including bilirubin, triglyceride, cholesterol, labile HbA(1c) (LA(1c)), vitamin C, aspirin, fetal haemoglobin (HbF), and haemoglobin E (Hb E)) were performed on Capillarys 2 Flex Piercing (Capillarys 2FP) (Sebia, France), Tosoh HLC-723 G8 (Tosoh G8) (Tosoh, Japan), Premier Hb9210 (Trinity Biotech, Ireland) and Roche Cobas c501 (Roche c501) (Roche Diagnostics, Germany). RESULTS: A good precision was shown at both low and high HbA(1c) levels on all four systems, with all individual CVs below 2% (IFCC units) or 1.5% (NGSP units). Linearity analysis for each analyzer had achieved a good correlation coefficient (R(2) > 0.99) over the entire range tested. The analytical bias of the four systems against the IFCC targets was less than ± 6% (NGSP units), indicating a good accuracy. Method comparison showed a great correlation and agreement between methods. Very high levels of triglycerides and cholesterol (≥ 15.28 and ≥ 8.72 mmol/L, respectively) led to falsely low HbA(1c) concentrations on Roche c501. Elevated HbF induced false HbA(1c) detection on Capillarys 2FP (> 10%), Tosoh G8 (> 30%), Premier Hb9210 (> 15%), and Roche c501 (> 5%). On Tosoh G8, HbE induced an extra peak on chromatogram, and significantly lower results were reported. CONCLUSIONS: The four HbA(1c) methods commonly used with commercial analyzers showed a good reliability and comparability, although some interference may falsely alter the result. Croatian Society of Medical Biochemistry and Laboratory Medicine 2016-10-15 2016-10-15 /pmc/articles/PMC5082223/ /pubmed/27812304 http://dx.doi.org/10.11613/BM.2016.039 Text en
spellingShingle Original Papers
Wu, Xiaobin
Chao, Yan
Wan, Zemin
Wang, Yunxiu
Ma, Yan
Ke, Peifeng
Wu, Xinzhong
Xu, Jianhua
Zhuang, Junhua
Huang, Xianzhang
A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title_full A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title_fullStr A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title_full_unstemmed A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title_short A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA(1c) determination
title_sort comparative evaluation of the analytical performances of capillarys 2 flex piercing, tosoh hlc-723 g8, premier hb9210, and roche cobas c501 tina-quant gen 2 analyzers for hba(1c) determination
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082223/
https://www.ncbi.nlm.nih.gov/pubmed/27812304
http://dx.doi.org/10.11613/BM.2016.039
work_keys_str_mv AT wuxiaobin acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT chaoyan acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wanzemin acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wangyunxiu acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT mayan acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT kepeifeng acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wuxinzhong acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT xujianhua acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT zhuangjunhua acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT huangxianzhang acomparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wuxiaobin comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT chaoyan comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wanzemin comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wangyunxiu comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT mayan comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT kepeifeng comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT wuxinzhong comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT xujianhua comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT zhuangjunhua comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination
AT huangxianzhang comparativeevaluationoftheanalyticalperformancesofcapillarys2flexpiercingtosohhlc723g8premierhb9210androchecobasc501tinaquantgen2analyzersforhba1cdetermination