Cargando…
Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
OBJECTIVES: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS: Three repeated consecutive measurements were taken by two independent exami...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Galenos Publishing
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082262/ https://www.ncbi.nlm.nih.gov/pubmed/27800242 http://dx.doi.org/10.4274/tjo.16768 |
_version_ | 1782463023599845376 |
---|---|
author | Altıparmak, Zeynep Yağcı, Ramazan Güler, Emre Arslanyılmaz, Zeynel Canbal, Metin Hepşen, İbrahim F. |
author_facet | Altıparmak, Zeynep Yağcı, Ramazan Güler, Emre Arslanyılmaz, Zeynel Canbal, Metin Hepşen, İbrahim F. |
author_sort | Altıparmak, Zeynep |
collection | PubMed |
description | OBJECTIVES: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the within-subject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. RESULTS: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. CONCLUSION: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. |
format | Online Article Text |
id | pubmed-5082262 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Galenos Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-50822622016-10-31 Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer Altıparmak, Zeynep Yağcı, Ramazan Güler, Emre Arslanyılmaz, Zeynel Canbal, Metin Hepşen, İbrahim F. Turk J Ophthalmol Original Article OBJECTIVES: To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS: Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the within-subject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. RESULTS: Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. CONCLUSION: The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes. Galenos Publishing 2015-12 2015-12-05 /pmc/articles/PMC5082262/ /pubmed/27800242 http://dx.doi.org/10.4274/tjo.16768 Text en ©Turkish Journal of Ophthalmology, Published by Galenos Publishing. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Altıparmak, Zeynep Yağcı, Ramazan Güler, Emre Arslanyılmaz, Zeynel Canbal, Metin Hepşen, İbrahim F. Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title | Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title_full | Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title_fullStr | Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title_full_unstemmed | Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title_short | Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer |
title_sort | repeatability and reproducibility of anterior segment measurements in normal eyes using dual scheimpflug analyzer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082262/ https://www.ncbi.nlm.nih.gov/pubmed/27800242 http://dx.doi.org/10.4274/tjo.16768 |
work_keys_str_mv | AT altıparmakzeynep repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer AT yagcıramazan repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer AT guleremre repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer AT arslanyılmazzeynel repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer AT canbalmetin repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer AT hepsenibrahimf repeatabilityandreproducibilityofanteriorsegmentmeasurementsinnormaleyesusingdualscheimpfluganalyzer |