Cargando…

Measuring the criticality of the ‘magic condition’ for a beam-expanding monochromator

It has been established that for cylindrically bent crystals the optimal beam characteristics occur when the geometric and single-ray foci are matched. In the beam-expanding monochromator developed for the BioMedical Imaging and Therapy beamlines at the Canadian Light Source, it was unclear how crit...

Descripción completa

Detalles Bibliográficos
Autores principales: Martinson, Mercedes, Chapman, Dean
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082467/
https://www.ncbi.nlm.nih.gov/pubmed/27787256
http://dx.doi.org/10.1107/S1600577516012650
Descripción
Sumario:It has been established that for cylindrically bent crystals the optimal beam characteristics occur when the geometric and single-ray foci are matched. In the beam-expanding monochromator developed for the BioMedical Imaging and Therapy beamlines at the Canadian Light Source, it was unclear how critical this ‘magic condition’ was for preserving the transverse coherence of the beam. A study was conducted to determine whether misalignments away from the ideal conditions would severely affect the transverse coherence of the beam, thereby limiting phase-based imaging techniques. The results were that the magic condition has enough flexibility to accommodate deviations of about ±1° or ±5 keV.