Cargando…

Calibration Method of an Ultrasonic System for Temperature Measurement

System calibration is fundamental to the overall accuracy of the ultrasonic temperature measurement, and it is basically involved in accurately measuring the path length and the system latency of the ultrasonic system. This paper proposes a method of high accuracy system calibration. By estimating t...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Chao, Wang, Yueke, Qiao, Chunjie, Dai, Weihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082948/
https://www.ncbi.nlm.nih.gov/pubmed/27788252
http://dx.doi.org/10.1371/journal.pone.0165335
_version_ 1782463157920333824
author Zhou, Chao
Wang, Yueke
Qiao, Chunjie
Dai, Weihua
author_facet Zhou, Chao
Wang, Yueke
Qiao, Chunjie
Dai, Weihua
author_sort Zhou, Chao
collection PubMed
description System calibration is fundamental to the overall accuracy of the ultrasonic temperature measurement, and it is basically involved in accurately measuring the path length and the system latency of the ultrasonic system. This paper proposes a method of high accuracy system calibration. By estimating the time delay between the transmitted signal and the received signal at several different temperatures, the calibration equations are constructed, and the calibrated results are determined with the use of the least squares algorithm. The formulas are deduced for calculating the calibration uncertainties, and the possible influential factors are analyzed. The experimental results in distilled water show that the calibrated path length and system latency can achieve uncertainties of 0.058 mm and 0.038 μs, respectively, and the temperature accuracy is significantly improved by using the calibrated results. The temperature error remains within ±0.04°C consistently, and the percentage error is less than 0.15%.
format Online
Article
Text
id pubmed-5082948
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50829482016-11-04 Calibration Method of an Ultrasonic System for Temperature Measurement Zhou, Chao Wang, Yueke Qiao, Chunjie Dai, Weihua PLoS One Research Article System calibration is fundamental to the overall accuracy of the ultrasonic temperature measurement, and it is basically involved in accurately measuring the path length and the system latency of the ultrasonic system. This paper proposes a method of high accuracy system calibration. By estimating the time delay between the transmitted signal and the received signal at several different temperatures, the calibration equations are constructed, and the calibrated results are determined with the use of the least squares algorithm. The formulas are deduced for calculating the calibration uncertainties, and the possible influential factors are analyzed. The experimental results in distilled water show that the calibrated path length and system latency can achieve uncertainties of 0.058 mm and 0.038 μs, respectively, and the temperature accuracy is significantly improved by using the calibrated results. The temperature error remains within ±0.04°C consistently, and the percentage error is less than 0.15%. Public Library of Science 2016-10-27 /pmc/articles/PMC5082948/ /pubmed/27788252 http://dx.doi.org/10.1371/journal.pone.0165335 Text en © 2016 Zhou et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Zhou, Chao
Wang, Yueke
Qiao, Chunjie
Dai, Weihua
Calibration Method of an Ultrasonic System for Temperature Measurement
title Calibration Method of an Ultrasonic System for Temperature Measurement
title_full Calibration Method of an Ultrasonic System for Temperature Measurement
title_fullStr Calibration Method of an Ultrasonic System for Temperature Measurement
title_full_unstemmed Calibration Method of an Ultrasonic System for Temperature Measurement
title_short Calibration Method of an Ultrasonic System for Temperature Measurement
title_sort calibration method of an ultrasonic system for temperature measurement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5082948/
https://www.ncbi.nlm.nih.gov/pubmed/27788252
http://dx.doi.org/10.1371/journal.pone.0165335
work_keys_str_mv AT zhouchao calibrationmethodofanultrasonicsystemfortemperaturemeasurement
AT wangyueke calibrationmethodofanultrasonicsystemfortemperaturemeasurement
AT qiaochunjie calibrationmethodofanultrasonicsystemfortemperaturemeasurement
AT daiweihua calibrationmethodofanultrasonicsystemfortemperaturemeasurement