Cargando…

A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems

A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise f...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Sung-Jin, Hong, Seong-Kwan, Kwon, Oh-Kyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087533/
https://www.ncbi.nlm.nih.gov/pubmed/27775623
http://dx.doi.org/10.3390/s16101748
_version_ 1782463934702288896
author Jung, Sung-Jin
Hong, Seong-Kwan
Kwon, Oh-Kyong
author_facet Jung, Sung-Jin
Hong, Seong-Kwan
Kwon, Oh-Kyong
author_sort Jung, Sung-Jin
collection PubMed
description A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise from scattering and electrical noise without using complex and bulky circuits. In addition, an asynchronous fastest signal identifier and a self-trimmed comparator are proposed to identify the fastest signal without using a high-frequency clock and to reduce misidentification, respectively. The channel reduction ratio of the proposed ROIC is 16:1 and can be extended to 16 × N:1 using N ROICs. To verify the performance of the two-step FSI, the proposed ROIC was implemented into a gamma photon detector module using a Geiger-mode avalanche photodiode with a lutetium-yttrium oxyorthosilicate array. The measured minimum detectable time is 1 ns. The difference of the measured energy and timing resolution between with and without the two-step FSI are 0.8% and 0.2 ns, respectively, which are negligibly small. These measurement results show that the proposed ROIC using the two-step FSI reduces the number of input channels of the DAQ block without sacrificing the performance of the positron emission tomography (PET) systems.
format Online
Article
Text
id pubmed-5087533
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-50875332016-11-07 A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems Jung, Sung-Jin Hong, Seong-Kwan Kwon, Oh-Kyong Sensors (Basel) Article A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise from scattering and electrical noise without using complex and bulky circuits. In addition, an asynchronous fastest signal identifier and a self-trimmed comparator are proposed to identify the fastest signal without using a high-frequency clock and to reduce misidentification, respectively. The channel reduction ratio of the proposed ROIC is 16:1 and can be extended to 16 × N:1 using N ROICs. To verify the performance of the two-step FSI, the proposed ROIC was implemented into a gamma photon detector module using a Geiger-mode avalanche photodiode with a lutetium-yttrium oxyorthosilicate array. The measured minimum detectable time is 1 ns. The difference of the measured energy and timing resolution between with and without the two-step FSI are 0.8% and 0.2 ns, respectively, which are negligibly small. These measurement results show that the proposed ROIC using the two-step FSI reduces the number of input channels of the DAQ block without sacrificing the performance of the positron emission tomography (PET) systems. MDPI 2016-10-20 /pmc/articles/PMC5087533/ /pubmed/27775623 http://dx.doi.org/10.3390/s16101748 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jung, Sung-Jin
Hong, Seong-Kwan
Kwon, Oh-Kyong
A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title_full A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title_fullStr A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title_full_unstemmed A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title_short A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
title_sort readout ic using two-step fastest signal identification for compact data acquisition of pet systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087533/
https://www.ncbi.nlm.nih.gov/pubmed/27775623
http://dx.doi.org/10.3390/s16101748
work_keys_str_mv AT jungsungjin areadouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems
AT hongseongkwan areadouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems
AT kwonohkyong areadouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems
AT jungsungjin readouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems
AT hongseongkwan readouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems
AT kwonohkyong readouticusingtwostepfastestsignalidentificationforcompactdataacquisitionofpetsystems