Cargando…
Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera
Kompsat-3A, which was launched on 25 March 2015, is a sister spacecraft of the Kompsat-3 developed by the Korea Aerospace Research Institute (KARI). Kompsat-3A’s AEISS-A (Advanced Electronic Image Scanning System-A) camera is similar to Kompsat-3’s AEISS but it was designed to provide PAN (Panchroma...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087559/ https://www.ncbi.nlm.nih.gov/pubmed/27783054 http://dx.doi.org/10.3390/s16101776 |
_version_ | 1782463940878401536 |
---|---|
author | Seo, Doocheon Oh, Jaehong Lee, Changno Lee, Donghan Choi, Haejin |
author_facet | Seo, Doocheon Oh, Jaehong Lee, Changno Lee, Donghan Choi, Haejin |
author_sort | Seo, Doocheon |
collection | PubMed |
description | Kompsat-3A, which was launched on 25 March 2015, is a sister spacecraft of the Kompsat-3 developed by the Korea Aerospace Research Institute (KARI). Kompsat-3A’s AEISS-A (Advanced Electronic Image Scanning System-A) camera is similar to Kompsat-3’s AEISS but it was designed to provide PAN (Panchromatic) resolution of 0.55 m, MS (multispectral) resolution of 2.20 m, and TIR (thermal infrared) at 5.5 m resolution. In this paper we present the geometric calibration and validation work of Kompsat-3A that was completed last year. A set of images over the test sites was taken for two months and was utilized for the work. The workflow includes the boresight calibration, CCDs (charge-coupled devices) alignment and focal length determination, the merge of two CCD lines, and the band-to-band registration. Then, the positional accuracies without any GCPs (ground control points) were validated for hundreds of test sites across the world using various image acquisition modes. In addition, we checked the planimetric accuracy by bundle adjustments with GCPs. |
format | Online Article Text |
id | pubmed-5087559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-50875592016-11-07 Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera Seo, Doocheon Oh, Jaehong Lee, Changno Lee, Donghan Choi, Haejin Sensors (Basel) Article Kompsat-3A, which was launched on 25 March 2015, is a sister spacecraft of the Kompsat-3 developed by the Korea Aerospace Research Institute (KARI). Kompsat-3A’s AEISS-A (Advanced Electronic Image Scanning System-A) camera is similar to Kompsat-3’s AEISS but it was designed to provide PAN (Panchromatic) resolution of 0.55 m, MS (multispectral) resolution of 2.20 m, and TIR (thermal infrared) at 5.5 m resolution. In this paper we present the geometric calibration and validation work of Kompsat-3A that was completed last year. A set of images over the test sites was taken for two months and was utilized for the work. The workflow includes the boresight calibration, CCDs (charge-coupled devices) alignment and focal length determination, the merge of two CCD lines, and the band-to-band registration. Then, the positional accuracies without any GCPs (ground control points) were validated for hundreds of test sites across the world using various image acquisition modes. In addition, we checked the planimetric accuracy by bundle adjustments with GCPs. MDPI 2016-10-24 /pmc/articles/PMC5087559/ /pubmed/27783054 http://dx.doi.org/10.3390/s16101776 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Seo, Doocheon Oh, Jaehong Lee, Changno Lee, Donghan Choi, Haejin Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title | Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title_full | Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title_fullStr | Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title_full_unstemmed | Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title_short | Geometric Calibration and Validation of Kompsat-3A AEISS-A Camera |
title_sort | geometric calibration and validation of kompsat-3a aeiss-a camera |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087559/ https://www.ncbi.nlm.nih.gov/pubmed/27783054 http://dx.doi.org/10.3390/s16101776 |
work_keys_str_mv | AT seodoocheon geometriccalibrationandvalidationofkompsat3aaeissacamera AT ohjaehong geometriccalibrationandvalidationofkompsat3aaeissacamera AT leechangno geometriccalibrationandvalidationofkompsat3aaeissacamera AT leedonghan geometriccalibrationandvalidationofkompsat3aaeissacamera AT choihaejin geometriccalibrationandvalidationofkompsat3aaeissacamera |