Cargando…
Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke
OBJECTIVE: The timed ‘Up & Go’ test and ‘30second Chair-Stand’ test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087865/ https://www.ncbi.nlm.nih.gov/pubmed/27798686 http://dx.doi.org/10.1371/journal.pone.0165663 |
_version_ | 1782463986738921472 |
---|---|
author | Lyders Johansen, Katrine Derby Stistrup, Rikke Skibdal Schjøtt, Camilla Madsen, Jacqueline Vinther, Anders |
author_facet | Lyders Johansen, Katrine Derby Stistrup, Rikke Skibdal Schjøtt, Camilla Madsen, Jacqueline Vinther, Anders |
author_sort | Lyders Johansen, Katrine |
collection | PubMed |
description | OBJECTIVE: The timed ‘Up & Go’ test and ‘30second Chair-Stand’ test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC(2,1)) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error of Measurement (with 95% certainty—SEM(95)) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM(95)% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed ‘Up & Go’ test and 0.88 and 0.94 for ‘30second Chair-Stand’ test, respectively. ICC values for intrarater reliability were 0.95 and 0.96 for the timed ‘Up & Go’ test and 0.87 and 0.91 for ‘30second Chair-Stand’ test, respectively. Heteroscedasticity was observed in the timed ‘Up & Go’ test. Interrater SEM(95)% ranged from 9.8% to 14.2% with corresponding SRD% of 13.9–20.1%. Intrarater SEM(95)% ranged from 15.8% to 18.7% with corresponding SRD% of 22.3–26.5%. For ‘30second Chair-Stand’ test interrater SEM(95) ranged between 1.5 and 1.9 repetitions with corresponding SRD of 2 and 3 and intrarater SEM(95) ranged between 1.8 and 2.0 repetitions with corresponding SRD values of 3. CONCLUSION: Excellent reliability was observed for the timed ‘Up & Go’ test and the ‘30second Chair-Stand’ test in hospitalised stroke patients. The thresholds to detect a real change in performance were 18.7% for the timed ‘Up & Go’ test and 2.0 repetitions for the ‘30second Chair-Stand’ in groups of patients and 26.5% and 3 repetitions in individual patients, respectively. |
format | Online Article Text |
id | pubmed-5087865 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-50878652016-11-15 Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke Lyders Johansen, Katrine Derby Stistrup, Rikke Skibdal Schjøtt, Camilla Madsen, Jacqueline Vinther, Anders PLoS One Research Article OBJECTIVE: The timed ‘Up & Go’ test and ‘30second Chair-Stand’ test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC(2,1)) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error of Measurement (with 95% certainty—SEM(95)) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM(95)% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed ‘Up & Go’ test and 0.88 and 0.94 for ‘30second Chair-Stand’ test, respectively. ICC values for intrarater reliability were 0.95 and 0.96 for the timed ‘Up & Go’ test and 0.87 and 0.91 for ‘30second Chair-Stand’ test, respectively. Heteroscedasticity was observed in the timed ‘Up & Go’ test. Interrater SEM(95)% ranged from 9.8% to 14.2% with corresponding SRD% of 13.9–20.1%. Intrarater SEM(95)% ranged from 15.8% to 18.7% with corresponding SRD% of 22.3–26.5%. For ‘30second Chair-Stand’ test interrater SEM(95) ranged between 1.5 and 1.9 repetitions with corresponding SRD of 2 and 3 and intrarater SEM(95) ranged between 1.8 and 2.0 repetitions with corresponding SRD values of 3. CONCLUSION: Excellent reliability was observed for the timed ‘Up & Go’ test and the ‘30second Chair-Stand’ test in hospitalised stroke patients. The thresholds to detect a real change in performance were 18.7% for the timed ‘Up & Go’ test and 2.0 repetitions for the ‘30second Chair-Stand’ in groups of patients and 26.5% and 3 repetitions in individual patients, respectively. Public Library of Science 2016-10-31 /pmc/articles/PMC5087865/ /pubmed/27798686 http://dx.doi.org/10.1371/journal.pone.0165663 Text en © 2016 Lyders Johansen et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Lyders Johansen, Katrine Derby Stistrup, Rikke Skibdal Schjøtt, Camilla Madsen, Jacqueline Vinther, Anders Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title | Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title_full | Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title_fullStr | Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title_full_unstemmed | Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title_short | Absolute and Relative Reliability of the Timed ‘Up & Go’ Test and ‘30second Chair-Stand’ Test in Hospitalised Patients with Stroke |
title_sort | absolute and relative reliability of the timed ‘up & go’ test and ‘30second chair-stand’ test in hospitalised patients with stroke |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087865/ https://www.ncbi.nlm.nih.gov/pubmed/27798686 http://dx.doi.org/10.1371/journal.pone.0165663 |
work_keys_str_mv | AT lydersjohansenkatrine absoluteandrelativereliabilityofthetimedupgotestand30secondchairstandtestinhospitalisedpatientswithstroke AT derbystistruprikke absoluteandrelativereliabilityofthetimedupgotestand30secondchairstandtestinhospitalisedpatientswithstroke AT skibdalschjøttcamilla absoluteandrelativereliabilityofthetimedupgotestand30secondchairstandtestinhospitalisedpatientswithstroke AT madsenjacqueline absoluteandrelativereliabilityofthetimedupgotestand30secondchairstandtestinhospitalisedpatientswithstroke AT vintheranders absoluteandrelativereliabilityofthetimedupgotestand30secondchairstandtestinhospitalisedpatientswithstroke |