Cargando…

Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective

BACKGROUND: Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient’s compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices...

Descripción completa

Detalles Bibliográficos
Autores principales: van Lieshout, Remko, Pisters, Martijn F., Vanwanseele, Benedicte, de Bie, Rob A., Wouters, Eveline J., Stukstette, Mirelle J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087887/
https://www.ncbi.nlm.nih.gov/pubmed/27798674
http://dx.doi.org/10.1371/journal.pone.0165199
_version_ 1782463989159034880
author van Lieshout, Remko
Pisters, Martijn F.
Vanwanseele, Benedicte
de Bie, Rob A.
Wouters, Eveline J.
Stukstette, Mirelle J.
author_facet van Lieshout, Remko
Pisters, Martijn F.
Vanwanseele, Benedicte
de Bie, Rob A.
Wouters, Eveline J.
Stukstette, Mirelle J.
author_sort van Lieshout, Remko
collection PubMed
description BACKGROUND: Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient’s compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user’s perspective. AIM: To describe the usability from the physical therapists’ and a patients’ perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. METHODS: In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. RESULTS: Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. CONCLUSION: This study gives insight in the usability of two biofeedback devices from the patient’s and physical therapist’s perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient’s perspective. IMPLICATION: The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices.
format Online
Article
Text
id pubmed-5087887
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50878872016-11-15 Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective van Lieshout, Remko Pisters, Martijn F. Vanwanseele, Benedicte de Bie, Rob A. Wouters, Eveline J. Stukstette, Mirelle J. PLoS One Research Article BACKGROUND: Partial weight bearing is frequently instructed by physical therapists in patients after lower-limb trauma or surgery. The use of biofeedback devices seems promising to improve the patient’s compliance with weight-bearing instructions. SmartStep and OpenGo-Science are biofeedback devices that provide real-time feedback. For a successful implementation, usability of the devices is a critical aspect and should be tested from a user’s perspective. AIM: To describe the usability from the physical therapists’ and a patients’ perspective of Smartstep and OpenGo-Science to provide feedback on partial weight bearing during supervised rehabilitation of patients after lower-limb trauma or surgery. METHODS: In a convergent mixed-methods design, qualitative and quantitative data were collected. Usability was subdivided into user performance, satisfaction and acceptability. Patients prescribed with partial weight bearing and their physical therapists were asked to use SmartStep and OpenGo-Science during supervised rehabilitation. Usability was qualitatively tested by a think-aloud method and a semi-structured interview and quantitatively tested by the System-Usability-Scale (SUS) and closed questions. For the qualitative data thematic content analyses were used. RESULTS: Nine pairs of physical therapists and their patients participated. The mean SUS scores for patients and physical therapists were for SmartStep 70 and 53, and for OpenGo-Science 79 and 81, respectively. Scores were interpreted with the Curved Grading Scale. The qualitative data showed that there were mixed views and perceptions from patients and physical therapists on satisfaction and acceptability. CONCLUSION: This study gives insight in the usability of two biofeedback devices from the patient’s and physical therapist’s perspective. The overall usability from both perspectives seemed to be acceptable for OpenGo-Science. For SmartStep, overall usability seemed only acceptable from the patient’s perspective. IMPLICATION: The study findings could help clinicians to decide which biofeedback device is appropriate for their given situation and provide information for future development of biofeedback devices. Public Library of Science 2016-10-31 /pmc/articles/PMC5087887/ /pubmed/27798674 http://dx.doi.org/10.1371/journal.pone.0165199 Text en © 2016 van Lieshout et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
van Lieshout, Remko
Pisters, Martijn F.
Vanwanseele, Benedicte
de Bie, Rob A.
Wouters, Eveline J.
Stukstette, Mirelle J.
Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title_full Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title_fullStr Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title_full_unstemmed Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title_short Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective
title_sort biofeedback in partial weight bearing: usability of two different devices from a patient’s and physical therapist’s perspective
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5087887/
https://www.ncbi.nlm.nih.gov/pubmed/27798674
http://dx.doi.org/10.1371/journal.pone.0165199
work_keys_str_mv AT vanlieshoutremko biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective
AT pistersmartijnf biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective
AT vanwanseelebenedicte biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective
AT debieroba biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective
AT woutersevelinej biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective
AT stukstettemirellej biofeedbackinpartialweightbearingusabilityoftwodifferentdevicesfromapatientsandphysicaltherapistsperspective