Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry

The cytokinesis‐block micronucleus (CBMN) assay is a well‐established technique that can be employed in triage radiation biodosimetry to estimate whole body doses of radiation to potentially exposed individuals through quantitation of the frequency of micronuclei (MN) in binucleated lymphocyte cells...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodrigues, M. A., Probst, C. E., Beaton‐Green, L. A., Wilkins, R. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5089661/
https://www.ncbi.nlm.nih.gov/pubmed/27272602
http://dx.doi.org/10.1002/cyto.a.22887
_version_ 1782464279124901888
author Rodrigues, M. A.
Probst, C. E.
Beaton‐Green, L. A.
Wilkins, R. C.
author_facet Rodrigues, M. A.
Probst, C. E.
Beaton‐Green, L. A.
Wilkins, R. C.
author_sort Rodrigues, M. A.
collection PubMed
description The cytokinesis‐block micronucleus (CBMN) assay is a well‐established technique that can be employed in triage radiation biodosimetry to estimate whole body doses of radiation to potentially exposed individuals through quantitation of the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay has been partially automated using traditional microscope‐based methods and most recently has been modified for application on the ImageStream(X) (IS(X)) imaging flow cytometer. This modification has allowed for a similar number of BNCs to be automatically scored as compared to traditional microscopy in a much shorter time period. However, the MN frequency measured was much lower than both manual and automated slide‐based methods of performing the assay. This work describes the optimized analysis template which implements newly developed functions in the IDEAS(®) data analysis software for the IS(X) that enhances specificity for BNCs and increases the frequency of scored MN. A new dose response calibration curve is presented in which the average rate of MN per BNC is of similar magnitude to those presented in the literature using automated CBMN slide scoring methods. In addition, dose estimates were generated for nine irradiated, blinded samples and were found to be within ±0.5 Gy of the delivered dose. Results demonstrate that the improved identification accuracy for MN and BNCs in the IS(X)‐based version of the CBMN assay will translate to increased accuracy when estimating unknown radiation doses received by exposed individuals following large‐scale radiological or nuclear emergencies. © 2016 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC
format Online
Article
Text
id pubmed-5089661
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50896612016-11-09 Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry Rodrigues, M. A. Probst, C. E. Beaton‐Green, L. A. Wilkins, R. C. Cytometry A Original Articles The cytokinesis‐block micronucleus (CBMN) assay is a well‐established technique that can be employed in triage radiation biodosimetry to estimate whole body doses of radiation to potentially exposed individuals through quantitation of the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay has been partially automated using traditional microscope‐based methods and most recently has been modified for application on the ImageStream(X) (IS(X)) imaging flow cytometer. This modification has allowed for a similar number of BNCs to be automatically scored as compared to traditional microscopy in a much shorter time period. However, the MN frequency measured was much lower than both manual and automated slide‐based methods of performing the assay. This work describes the optimized analysis template which implements newly developed functions in the IDEAS(®) data analysis software for the IS(X) that enhances specificity for BNCs and increases the frequency of scored MN. A new dose response calibration curve is presented in which the average rate of MN per BNC is of similar magnitude to those presented in the literature using automated CBMN slide scoring methods. In addition, dose estimates were generated for nine irradiated, blinded samples and were found to be within ±0.5 Gy of the delivered dose. Results demonstrate that the improved identification accuracy for MN and BNCs in the IS(X)‐based version of the CBMN assay will translate to increased accuracy when estimating unknown radiation doses received by exposed individuals following large‐scale radiological or nuclear emergencies. © 2016 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC John Wiley and Sons Inc. 2016-06-06 2016-07 /pmc/articles/PMC5089661/ /pubmed/27272602 http://dx.doi.org/10.1002/cyto.a.22887 Text en © 2016 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Rodrigues, M. A.
Probst, C. E.
Beaton‐Green, L. A.
Wilkins, R. C.
Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title_full Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title_fullStr Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title_full_unstemmed Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title_short Optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
title_sort optimized automated data analysis for the cytokinesis‐block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5089661/
https://www.ncbi.nlm.nih.gov/pubmed/27272602
http://dx.doi.org/10.1002/cyto.a.22887
work_keys_str_mv AT rodriguesma optimizedautomateddataanalysisforthecytokinesisblockmicronucleusassayusingimagingflowcytometryforhighthroughputradiationbiodosimetry
AT probstce optimizedautomateddataanalysisforthecytokinesisblockmicronucleusassayusingimagingflowcytometryforhighthroughputradiationbiodosimetry
AT beatongreenla optimizedautomateddataanalysisforthecytokinesisblockmicronucleusassayusingimagingflowcytometryforhighthroughputradiationbiodosimetry
AT wilkinsrc optimizedautomateddataanalysisforthecytokinesisblockmicronucleusassayusingimagingflowcytometryforhighthroughputradiationbiodosimetry