Cargando…

Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT

OBJECTIVES: Flat-panel CT (FPCT) allows cross-sectional parenchymal, vascular and perfusion imaging within the angiography suite, which could greatly facilitate acute stroke management. We hypothesized that FPCT offers equal diagnostic accuracy compared to multi-detector CT (MDCT) as a primary tool...

Descripción completa

Detalles Bibliográficos
Autores principales: Frölich, Andreas M., Buhk, Jan-Hendrik, Fiehler, Jens, Kemmling, Andre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5091958/
https://www.ncbi.nlm.nih.gov/pubmed/27806106
http://dx.doi.org/10.1371/journal.pone.0165794
_version_ 1782464660670251008
author Frölich, Andreas M.
Buhk, Jan-Hendrik
Fiehler, Jens
Kemmling, Andre
author_facet Frölich, Andreas M.
Buhk, Jan-Hendrik
Fiehler, Jens
Kemmling, Andre
author_sort Frölich, Andreas M.
collection PubMed
description OBJECTIVES: Flat-panel CT (FPCT) allows cross-sectional parenchymal, vascular and perfusion imaging within the angiography suite, which could greatly facilitate acute stroke management. We hypothesized that FPCT offers equal diagnostic accuracy compared to multi-detector CT (MDCT) as a primary tool to exclude intracranial hemorrhage. METHODS: 22 patients with intracranial hematomas who had both MDCT and FPCT performed within 24 hours were retrospectively identified. Patients with visible change in hematoma size or configuration were excluded. Two raters independently segmented hemorrhagic lesions. Data sets and corresponding binary lesion maps were co-registered to compare hematoma volume. Diagnostic accuracy of FPCT to detect hemorrhage was calculated from voxel-wise analysis of lesion overlap compared to reference MDCT. RESULTS: Mean hematoma size was similar between MDCT (16.2±8.9 ml) and FPCT (16.1±8.6 ml), with near perfect correlation of hematoma sizes between modalities (ρ = 0.95, p<0.001). Sensitivity and specificity of FPCT to detect hemorrhagic voxels was 61.6% and 99.8% for intraventricular hematomas and 67.7% and 99.5% for all other intracranial hematomas. CONCLUSIONS: In this small sample containing predominantly cases with subarachnoid hemorrhage, FPCT based assessment of hemorrhagic volume in brain yields acceptable accuracy compared to reference MDCT, albeit with a limited sensitivity on a voxel level. Further assessment and improvement of FPCT is necessary before it can be applied as a primary imaging modality to exclude intracranial hemorrhage in acute stroke patients.
format Online
Article
Text
id pubmed-5091958
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50919582016-11-15 Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT Frölich, Andreas M. Buhk, Jan-Hendrik Fiehler, Jens Kemmling, Andre PLoS One Research Article OBJECTIVES: Flat-panel CT (FPCT) allows cross-sectional parenchymal, vascular and perfusion imaging within the angiography suite, which could greatly facilitate acute stroke management. We hypothesized that FPCT offers equal diagnostic accuracy compared to multi-detector CT (MDCT) as a primary tool to exclude intracranial hemorrhage. METHODS: 22 patients with intracranial hematomas who had both MDCT and FPCT performed within 24 hours were retrospectively identified. Patients with visible change in hematoma size or configuration were excluded. Two raters independently segmented hemorrhagic lesions. Data sets and corresponding binary lesion maps were co-registered to compare hematoma volume. Diagnostic accuracy of FPCT to detect hemorrhage was calculated from voxel-wise analysis of lesion overlap compared to reference MDCT. RESULTS: Mean hematoma size was similar between MDCT (16.2±8.9 ml) and FPCT (16.1±8.6 ml), with near perfect correlation of hematoma sizes between modalities (ρ = 0.95, p<0.001). Sensitivity and specificity of FPCT to detect hemorrhagic voxels was 61.6% and 99.8% for intraventricular hematomas and 67.7% and 99.5% for all other intracranial hematomas. CONCLUSIONS: In this small sample containing predominantly cases with subarachnoid hemorrhage, FPCT based assessment of hemorrhagic volume in brain yields acceptable accuracy compared to reference MDCT, albeit with a limited sensitivity on a voxel level. Further assessment and improvement of FPCT is necessary before it can be applied as a primary imaging modality to exclude intracranial hemorrhage in acute stroke patients. Public Library of Science 2016-11-02 /pmc/articles/PMC5091958/ /pubmed/27806106 http://dx.doi.org/10.1371/journal.pone.0165794 Text en © 2016 Frölich et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Frölich, Andreas M.
Buhk, Jan-Hendrik
Fiehler, Jens
Kemmling, Andre
Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title_full Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title_fullStr Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title_full_unstemmed Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title_short Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT
title_sort voxel-based sensitivity of flat-panel ct for the detection of intracranial hemorrhage: comparison to multi-detector ct
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5091958/
https://www.ncbi.nlm.nih.gov/pubmed/27806106
http://dx.doi.org/10.1371/journal.pone.0165794
work_keys_str_mv AT frolichandreasm voxelbasedsensitivityofflatpanelctforthedetectionofintracranialhemorrhagecomparisontomultidetectorct
AT buhkjanhendrik voxelbasedsensitivityofflatpanelctforthedetectionofintracranialhemorrhagecomparisontomultidetectorct
AT fiehlerjens voxelbasedsensitivityofflatpanelctforthedetectionofintracranialhemorrhagecomparisontomultidetectorct
AT kemmlingandre voxelbasedsensitivityofflatpanelctforthedetectionofintracranialhemorrhagecomparisontomultidetectorct