Cargando…
Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses
PURPOSE: To evaluate tear film stability and optical aberrations in eyes wearing plano Lotrafilcon B contact lenses (CL). METHODS: Tear Deformation Time (TDT) and aberrometric parameters were assessed in 86 normal emmetropic eyes before and 6 h after wearing CL. RESULT: A statistically significant d...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5093784/ https://www.ncbi.nlm.nih.gov/pubmed/27830209 http://dx.doi.org/10.1016/j.joco.2016.07.002 |
_version_ | 1782465001195307008 |
---|---|
author | Asharlous, Amir Jafarzadehpur, Ebrahim Mirzajani, Ali Khabazkhoob, Mehdi Heydarian, Samira Taghipour, Ali |
author_facet | Asharlous, Amir Jafarzadehpur, Ebrahim Mirzajani, Ali Khabazkhoob, Mehdi Heydarian, Samira Taghipour, Ali |
author_sort | Asharlous, Amir |
collection | PubMed |
description | PURPOSE: To evaluate tear film stability and optical aberrations in eyes wearing plano Lotrafilcon B contact lenses (CL). METHODS: Tear Deformation Time (TDT) and aberrometric parameters were assessed in 86 normal emmetropic eyes before and 6 h after wearing CL. RESULT: A statistically significant decrease in TDT and increase in root mean square (RMS) values of higher order aberrations (HOA) were revealed 6 h after CL insertion (both P < 0.001). The low order aberrations (LOA) RMS values measured with CL were higher than those in naked eyes, but the difference was not statistically significant. None of individual Zernike polynomials showed any significant alteration. CONCLUSION: Our findings indicated that the Lotrafilcon B contact lens affects HOA more than LOA. The tear film was less stable after wearing CL. |
format | Online Article Text |
id | pubmed-5093784 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-50937842016-11-09 Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses Asharlous, Amir Jafarzadehpur, Ebrahim Mirzajani, Ali Khabazkhoob, Mehdi Heydarian, Samira Taghipour, Ali J Curr Ophthalmol Brief Report PURPOSE: To evaluate tear film stability and optical aberrations in eyes wearing plano Lotrafilcon B contact lenses (CL). METHODS: Tear Deformation Time (TDT) and aberrometric parameters were assessed in 86 normal emmetropic eyes before and 6 h after wearing CL. RESULT: A statistically significant decrease in TDT and increase in root mean square (RMS) values of higher order aberrations (HOA) were revealed 6 h after CL insertion (both P < 0.001). The low order aberrations (LOA) RMS values measured with CL were higher than those in naked eyes, but the difference was not statistically significant. None of individual Zernike polynomials showed any significant alteration. CONCLUSION: Our findings indicated that the Lotrafilcon B contact lens affects HOA more than LOA. The tear film was less stable after wearing CL. Elsevier 2016-07-25 /pmc/articles/PMC5093784/ /pubmed/27830209 http://dx.doi.org/10.1016/j.joco.2016.07.002 Text en © 2016, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Brief Report Asharlous, Amir Jafarzadehpur, Ebrahim Mirzajani, Ali Khabazkhoob, Mehdi Heydarian, Samira Taghipour, Ali Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title | Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title_full | Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title_fullStr | Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title_full_unstemmed | Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title_short | Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses |
title_sort | tear deformation time and optical quality in eyes wearing silicone hydrogel contact lenses |
topic | Brief Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5093784/ https://www.ncbi.nlm.nih.gov/pubmed/27830209 http://dx.doi.org/10.1016/j.joco.2016.07.002 |
work_keys_str_mv | AT asharlousamir teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses AT jafarzadehpurebrahim teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses AT mirzajaniali teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses AT khabazkhoobmehdi teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses AT heydariansamira teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses AT taghipourali teardeformationtimeandopticalqualityineyeswearingsiliconehydrogelcontactlenses |