Cargando…
Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role i...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094401/ https://www.ncbi.nlm.nih.gov/pubmed/27818748 http://dx.doi.org/10.1093/ckj/sfs155 |
_version_ | 1782465096567488512 |
---|---|
author | Chen, Huan-Sheng Lee, Kuan-Chang Cheng, Chun-Ting Hou, Chun-Cheng Liou, Hung-Hsiang Lin, Chun-Ju Lim, Paik-Seong |
author_facet | Chen, Huan-Sheng Lee, Kuan-Chang Cheng, Chun-Ting Hou, Chun-Cheng Liou, Hung-Hsiang Lin, Chun-Ju Lim, Paik-Seong |
author_sort | Chen, Huan-Sheng |
collection | PubMed |
description | BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body composition monitor based on bioimpedance spectroscopy (BCM-BIS) applied in dialysis patients were analyzed to define the technique's feasibility, precision and possible role in dry weight determination. METHODS: BCM-BIS was applied monthly to 194 hemodialysis patients for 6 months. Intra-patient precision was analyzed. Bland–Altman analysis and repeated-measures analysis of variance (ANOVA) were used to define the relationship between the dry weights determined by BCM-BIS and by clinical judgment. RESULTS: The coefficients of variation (CVs) of fluid parameters were <5%. Serial changes in dry weight differences were compared in groups with different post-dialysis hydration status and dry weight differences decreased gradually. Bland–Altman analysis revealed that the range of these differences was significantly narrower towards the latter part of the study. The upper limit of agreement with 95% confidence interval (CI) was 1.47 L and the lower limit was −3.02 L. CONCLUSIONS: BCM-BIS is precise and can be easily applied in the clinical setting. Discrepancy between the dry weights determined by BCM-BIS and by clinical judgment significantly decreased during the study. It is sensitive in dry weight determination, especially for those patients with obvious over-hydration (OH) by BCM-BIS. Patients with post-dialysis OH results beyond some critical values (>1.5 L or <−3 L) should be closely monitored. |
format | Online Article Text |
id | pubmed-5094401 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-50944012016-11-04 Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation Chen, Huan-Sheng Lee, Kuan-Chang Cheng, Chun-Ting Hou, Chun-Cheng Liou, Hung-Hsiang Lin, Chun-Ju Lim, Paik-Seong Clin Kidney J Original Contributions BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body composition monitor based on bioimpedance spectroscopy (BCM-BIS) applied in dialysis patients were analyzed to define the technique's feasibility, precision and possible role in dry weight determination. METHODS: BCM-BIS was applied monthly to 194 hemodialysis patients for 6 months. Intra-patient precision was analyzed. Bland–Altman analysis and repeated-measures analysis of variance (ANOVA) were used to define the relationship between the dry weights determined by BCM-BIS and by clinical judgment. RESULTS: The coefficients of variation (CVs) of fluid parameters were <5%. Serial changes in dry weight differences were compared in groups with different post-dialysis hydration status and dry weight differences decreased gradually. Bland–Altman analysis revealed that the range of these differences was significantly narrower towards the latter part of the study. The upper limit of agreement with 95% confidence interval (CI) was 1.47 L and the lower limit was −3.02 L. CONCLUSIONS: BCM-BIS is precise and can be easily applied in the clinical setting. Discrepancy between the dry weights determined by BCM-BIS and by clinical judgment significantly decreased during the study. It is sensitive in dry weight determination, especially for those patients with obvious over-hydration (OH) by BCM-BIS. Patients with post-dialysis OH results beyond some critical values (>1.5 L or <−3 L) should be closely monitored. Oxford University Press 2013-02 2012-12-14 /pmc/articles/PMC5094401/ /pubmed/27818748 http://dx.doi.org/10.1093/ckj/sfs155 Text en © The Author 2012. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For permissions, please email: journals.permissions@oup.com http://creativecommons.org/licenses/by-nc/4.0/ this is an open access article distributed under the terms of the creative commons attribution non-commercial license (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. for commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Contributions Chen, Huan-Sheng Lee, Kuan-Chang Cheng, Chun-Ting Hou, Chun-Cheng Liou, Hung-Hsiang Lin, Chun-Ju Lim, Paik-Seong Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title | Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title_full | Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title_fullStr | Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title_full_unstemmed | Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title_short | Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation |
title_sort | application of bioimpedance spectroscopy in asian dialysis patients (abisad): serial follow-up and dry weight evaluation |
topic | Original Contributions |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094401/ https://www.ncbi.nlm.nih.gov/pubmed/27818748 http://dx.doi.org/10.1093/ckj/sfs155 |
work_keys_str_mv | AT chenhuansheng applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT leekuanchang applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT chengchunting applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT houchuncheng applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT liouhunghsiang applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT linchunju applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation AT limpaikseong applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation |