Cargando…

Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation

BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role i...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Huan-Sheng, Lee, Kuan-Chang, Cheng, Chun-Ting, Hou, Chun-Cheng, Liou, Hung-Hsiang, Lin, Chun-Ju, Lim, Paik-Seong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094401/
https://www.ncbi.nlm.nih.gov/pubmed/27818748
http://dx.doi.org/10.1093/ckj/sfs155
_version_ 1782465096567488512
author Chen, Huan-Sheng
Lee, Kuan-Chang
Cheng, Chun-Ting
Hou, Chun-Cheng
Liou, Hung-Hsiang
Lin, Chun-Ju
Lim, Paik-Seong
author_facet Chen, Huan-Sheng
Lee, Kuan-Chang
Cheng, Chun-Ting
Hou, Chun-Cheng
Liou, Hung-Hsiang
Lin, Chun-Ju
Lim, Paik-Seong
author_sort Chen, Huan-Sheng
collection PubMed
description BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body composition monitor based on bioimpedance spectroscopy (BCM-BIS) applied in dialysis patients were analyzed to define the technique's feasibility, precision and possible role in dry weight determination. METHODS: BCM-BIS was applied monthly to 194 hemodialysis patients for 6 months. Intra-patient precision was analyzed. Bland–Altman analysis and repeated-measures analysis of variance (ANOVA) were used to define the relationship between the dry weights determined by BCM-BIS and by clinical judgment. RESULTS: The coefficients of variation (CVs) of fluid parameters were <5%. Serial changes in dry weight differences were compared in groups with different post-dialysis hydration status and dry weight differences decreased gradually. Bland–Altman analysis revealed that the range of these differences was significantly narrower towards the latter part of the study. The upper limit of agreement with 95% confidence interval (CI) was 1.47 L and the lower limit was −3.02 L. CONCLUSIONS: BCM-BIS is precise and can be easily applied in the clinical setting. Discrepancy between the dry weights determined by BCM-BIS and by clinical judgment significantly decreased during the study. It is sensitive in dry weight determination, especially for those patients with obvious over-hydration (OH) by BCM-BIS. Patients with post-dialysis OH results beyond some critical values (>1.5 L or <−3 L) should be closely monitored.
format Online
Article
Text
id pubmed-5094401
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-50944012016-11-04 Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation Chen, Huan-Sheng Lee, Kuan-Chang Cheng, Chun-Ting Hou, Chun-Cheng Liou, Hung-Hsiang Lin, Chun-Ju Lim, Paik-Seong Clin Kidney J Original Contributions BACKGROUND: Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body composition monitor based on bioimpedance spectroscopy (BCM-BIS) applied in dialysis patients were analyzed to define the technique's feasibility, precision and possible role in dry weight determination. METHODS: BCM-BIS was applied monthly to 194 hemodialysis patients for 6 months. Intra-patient precision was analyzed. Bland–Altman analysis and repeated-measures analysis of variance (ANOVA) were used to define the relationship between the dry weights determined by BCM-BIS and by clinical judgment. RESULTS: The coefficients of variation (CVs) of fluid parameters were <5%. Serial changes in dry weight differences were compared in groups with different post-dialysis hydration status and dry weight differences decreased gradually. Bland–Altman analysis revealed that the range of these differences was significantly narrower towards the latter part of the study. The upper limit of agreement with 95% confidence interval (CI) was 1.47 L and the lower limit was −3.02 L. CONCLUSIONS: BCM-BIS is precise and can be easily applied in the clinical setting. Discrepancy between the dry weights determined by BCM-BIS and by clinical judgment significantly decreased during the study. It is sensitive in dry weight determination, especially for those patients with obvious over-hydration (OH) by BCM-BIS. Patients with post-dialysis OH results beyond some critical values (>1.5 L or <−3 L) should be closely monitored. Oxford University Press 2013-02 2012-12-14 /pmc/articles/PMC5094401/ /pubmed/27818748 http://dx.doi.org/10.1093/ckj/sfs155 Text en © The Author 2012. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For permissions, please email: journals.permissions@oup.com http://creativecommons.org/licenses/by-nc/4.0/ this is an open access article distributed under the terms of the creative commons attribution non-commercial license (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. for commercial re-use, please contact journals.permissions@oup.com
spellingShingle Original Contributions
Chen, Huan-Sheng
Lee, Kuan-Chang
Cheng, Chun-Ting
Hou, Chun-Cheng
Liou, Hung-Hsiang
Lin, Chun-Ju
Lim, Paik-Seong
Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title_full Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title_fullStr Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title_full_unstemmed Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title_short Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation
title_sort application of bioimpedance spectroscopy in asian dialysis patients (abisad): serial follow-up and dry weight evaluation
topic Original Contributions
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094401/
https://www.ncbi.nlm.nih.gov/pubmed/27818748
http://dx.doi.org/10.1093/ckj/sfs155
work_keys_str_mv AT chenhuansheng applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT leekuanchang applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT chengchunting applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT houchuncheng applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT liouhunghsiang applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT linchunju applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation
AT limpaikseong applicationofbioimpedancespectroscopyinasiandialysispatientsabisadserialfollowupanddryweightevaluation