Cargando…

Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis

BACKGROUND/AIMS: To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. METHODS: Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Hyoung-Chul, Kang, Hyun, Lee, Jae Young, Choi, Geun Joo, Choi, Jung Sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Association of Internal Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094933/
https://www.ncbi.nlm.nih.gov/pubmed/27586867
http://dx.doi.org/10.3904/kjim.2016.066
_version_ 1782465194927063040
author Oh, Hyoung-Chul
Kang, Hyun
Lee, Jae Young
Choi, Geun Joo
Choi, Jung Sik
author_facet Oh, Hyoung-Chul
Kang, Hyun
Lee, Jae Young
Choi, Geun Joo
Choi, Jung Sik
author_sort Oh, Hyoung-Chul
collection PubMed
description BACKGROUND/AIMS: To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. METHODS: Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. RESULTS: The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, –0.72; 95% CI, –1.02 to –0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). CONCLUSIONS: Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
format Online
Article
Text
id pubmed-5094933
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Association of Internal Medicine
record_format MEDLINE/PubMed
spelling pubmed-50949332016-11-04 Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis Oh, Hyoung-Chul Kang, Hyun Lee, Jae Young Choi, Geun Joo Choi, Jung Sik Korean J Intern Med Original Article BACKGROUND/AIMS: To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. METHODS: Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. RESULTS: The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, –0.72; 95% CI, –1.02 to –0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). CONCLUSIONS: Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile. The Korean Association of Internal Medicine 2016-11 2016-09-02 /pmc/articles/PMC5094933/ /pubmed/27586867 http://dx.doi.org/10.3904/kjim.2016.066 Text en Copyright © 2016 The Korean Association of Internal Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Oh, Hyoung-Chul
Kang, Hyun
Lee, Jae Young
Choi, Geun Joo
Choi, Jung Sik
Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title_full Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title_fullStr Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title_short Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
title_sort diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5094933/
https://www.ncbi.nlm.nih.gov/pubmed/27586867
http://dx.doi.org/10.3904/kjim.2016.066
work_keys_str_mv AT ohhyoungchul diagnosticaccuracyof2225gaugecoreneedleinendoscopicultrasoundguidedsamplingsystematicreviewandmetaanalysis
AT kanghyun diagnosticaccuracyof2225gaugecoreneedleinendoscopicultrasoundguidedsamplingsystematicreviewandmetaanalysis
AT leejaeyoung diagnosticaccuracyof2225gaugecoreneedleinendoscopicultrasoundguidedsamplingsystematicreviewandmetaanalysis
AT choigeunjoo diagnosticaccuracyof2225gaugecoreneedleinendoscopicultrasoundguidedsamplingsystematicreviewandmetaanalysis
AT choijungsik diagnosticaccuracyof2225gaugecoreneedleinendoscopicultrasoundguidedsamplingsystematicreviewandmetaanalysis