Cargando…

Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration

Occurrence of bronchial artery aneurysm is rare, and it has been detected in less than 1 % of all selective bronchial arteriography cases. Here, we present a case of a bronchial artery aneurysm caused by a tracheal stent migration. A 59-year-old man was operated on for esophageal cancer, where an es...

Descripción completa

Detalles Bibliográficos
Autores principales: Sato, Kiyoshi, Fumimoto, Satoshi, Fukada, Takehisa, Ochi, Kaoru, Kataoka, Takayuki, Ichihashi, Yoshio, Satomi, Hidetoshi, Morita, Takuya, Hanaoka, Nobuharu, Okada, Yoshikatsu, Katsumata, Takahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097054/
https://www.ncbi.nlm.nih.gov/pubmed/27815921
http://dx.doi.org/10.1186/s40792-016-0247-1
_version_ 1782465540129816576
author Sato, Kiyoshi
Fumimoto, Satoshi
Fukada, Takehisa
Ochi, Kaoru
Kataoka, Takayuki
Ichihashi, Yoshio
Satomi, Hidetoshi
Morita, Takuya
Hanaoka, Nobuharu
Okada, Yoshikatsu
Katsumata, Takahiro
author_facet Sato, Kiyoshi
Fumimoto, Satoshi
Fukada, Takehisa
Ochi, Kaoru
Kataoka, Takayuki
Ichihashi, Yoshio
Satomi, Hidetoshi
Morita, Takuya
Hanaoka, Nobuharu
Okada, Yoshikatsu
Katsumata, Takahiro
author_sort Sato, Kiyoshi
collection PubMed
description Occurrence of bronchial artery aneurysm is rare, and it has been detected in less than 1 % of all selective bronchial arteriography cases. Here, we present a case of a bronchial artery aneurysm caused by a tracheal stent migration. A 59-year-old man was operated on for esophageal cancer, where an esophageal-tracheal fistula occurred 1 week after operation. Surgical repair of the esophageal-tracheal fistula was performed using a muscle flap, but this not results in fistula closure. Consequently, a self-expanding covered metallic tracheal stent was implanted for rescue, and this resulted in fistula closure. After 1 year, there was frequent hemoptysis caused by migration of the stent. He was referred to our hospital where removal of the stent was planned. A sudden occurrence of massive bleeding from trachea occurred, and extracorporeal membrane oxygenation (ECMO) was used. Although removal of tracheal stent was performed successfully, the patient subsequently died from multi-organ failure. Post-mortem autopsy revealed that the massive bleeding is originated from the rupture of a bronchial artery aneurysm.
format Online
Article
Text
id pubmed-5097054
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-50970542016-11-18 Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration Sato, Kiyoshi Fumimoto, Satoshi Fukada, Takehisa Ochi, Kaoru Kataoka, Takayuki Ichihashi, Yoshio Satomi, Hidetoshi Morita, Takuya Hanaoka, Nobuharu Okada, Yoshikatsu Katsumata, Takahiro Surg Case Rep Case Report Occurrence of bronchial artery aneurysm is rare, and it has been detected in less than 1 % of all selective bronchial arteriography cases. Here, we present a case of a bronchial artery aneurysm caused by a tracheal stent migration. A 59-year-old man was operated on for esophageal cancer, where an esophageal-tracheal fistula occurred 1 week after operation. Surgical repair of the esophageal-tracheal fistula was performed using a muscle flap, but this not results in fistula closure. Consequently, a self-expanding covered metallic tracheal stent was implanted for rescue, and this resulted in fistula closure. After 1 year, there was frequent hemoptysis caused by migration of the stent. He was referred to our hospital where removal of the stent was planned. A sudden occurrence of massive bleeding from trachea occurred, and extracorporeal membrane oxygenation (ECMO) was used. Although removal of tracheal stent was performed successfully, the patient subsequently died from multi-organ failure. Post-mortem autopsy revealed that the massive bleeding is originated from the rupture of a bronchial artery aneurysm. Springer Berlin Heidelberg 2016-11-05 /pmc/articles/PMC5097054/ /pubmed/27815921 http://dx.doi.org/10.1186/s40792-016-0247-1 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Case Report
Sato, Kiyoshi
Fumimoto, Satoshi
Fukada, Takehisa
Ochi, Kaoru
Kataoka, Takayuki
Ichihashi, Yoshio
Satomi, Hidetoshi
Morita, Takuya
Hanaoka, Nobuharu
Okada, Yoshikatsu
Katsumata, Takahiro
Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title_full Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title_fullStr Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title_full_unstemmed Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title_short Bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
title_sort bronchial artery aneurysm suggested to be caused by metalic tracheal stent migration
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097054/
https://www.ncbi.nlm.nih.gov/pubmed/27815921
http://dx.doi.org/10.1186/s40792-016-0247-1
work_keys_str_mv AT satokiyoshi bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT fumimotosatoshi bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT fukadatakehisa bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT ochikaoru bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT kataokatakayuki bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT ichihashiyoshio bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT satomihidetoshi bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT moritatakuya bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT hanaokanobuharu bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT okadayoshikatsu bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration
AT katsumatatakahiro bronchialarteryaneurysmsuggestedtobecausedbymetalictrachealstentmigration