Cargando…

A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren

Previous research has reported the validity and reliability of a range of field-based tests of children’s cardiorespiratory fitness. These two criteria are critical in ensuring the integrity and credibility of data derived through such tests. However, the criterion of scalability has received little...

Descripción completa

Detalles Bibliográficos
Autores principales: Domone, Sarah, Mann, Steven, Sandercock, Gavin, Wade, Matthew, Beedie, Chris
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097078/
https://www.ncbi.nlm.nih.gov/pubmed/27229897
http://dx.doi.org/10.1007/s40279-016-0553-6
_version_ 1782465545944170496
author Domone, Sarah
Mann, Steven
Sandercock, Gavin
Wade, Matthew
Beedie, Chris
author_facet Domone, Sarah
Mann, Steven
Sandercock, Gavin
Wade, Matthew
Beedie, Chris
author_sort Domone, Sarah
collection PubMed
description Previous research has reported the validity and reliability of a range of field-based tests of children’s cardiorespiratory fitness. These two criteria are critical in ensuring the integrity and credibility of data derived through such tests. However, the criterion of scalability has received little attention. Scalability determines the degree to which tests developed on small samples in controlled settings might demonstrate real-world value, and is of increasing interest to policymakers and practitioners. The present paper proposes a method by which the scalability of cardiorespiratory field-based tests suitable for school-aged children might be assessed. We developed an algorithm to estimate scalability based on a six-component model; delivery, evidence of operating at scale, effectiveness, costs, resource requirements and practical implementation. We tested the algorithm on data derived through a systematic review of research that has used relevant fitness tests. A total of 229 studies that had used field based cardiorespiratory fitness tests to measure children’s fitness were identified. Initial analyses indicated that the 5-min run test did not meet accepted criteria for reliability, whilst the 6-min walk test likewise failed to meet the criteria for validity. Of the remainder, a total of 28 studies met the inclusion criteria, 22 reporting the 20-m shuttle-run and seven the 1-mile walk/run. Using the scalability algorithm we demonstrate that the 20-m shuttle run test is substantially more scalable than the 1-mile walk/run test, with tests scoring 34/48 and 25/48, respectively. A comprehensive analysis of scalability was prohibited by the widespread non-reporting of data, for example, those relating to cost-effectiveness. Of all sufficiently valid and reliable candidate tests identified, using our algorithm the 20-m shuttle run test was identified as the most scalable. We hope that the algorithm will prove useful in the examination of scalability in either new data relating to existing tests or in data pertaining to new tests.
format Online
Article
Text
id pubmed-5097078
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-50970782016-11-21 A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren Domone, Sarah Mann, Steven Sandercock, Gavin Wade, Matthew Beedie, Chris Sports Med Review Article Previous research has reported the validity and reliability of a range of field-based tests of children’s cardiorespiratory fitness. These two criteria are critical in ensuring the integrity and credibility of data derived through such tests. However, the criterion of scalability has received little attention. Scalability determines the degree to which tests developed on small samples in controlled settings might demonstrate real-world value, and is of increasing interest to policymakers and practitioners. The present paper proposes a method by which the scalability of cardiorespiratory field-based tests suitable for school-aged children might be assessed. We developed an algorithm to estimate scalability based on a six-component model; delivery, evidence of operating at scale, effectiveness, costs, resource requirements and practical implementation. We tested the algorithm on data derived through a systematic review of research that has used relevant fitness tests. A total of 229 studies that had used field based cardiorespiratory fitness tests to measure children’s fitness were identified. Initial analyses indicated that the 5-min run test did not meet accepted criteria for reliability, whilst the 6-min walk test likewise failed to meet the criteria for validity. Of the remainder, a total of 28 studies met the inclusion criteria, 22 reporting the 20-m shuttle-run and seven the 1-mile walk/run. Using the scalability algorithm we demonstrate that the 20-m shuttle run test is substantially more scalable than the 1-mile walk/run test, with tests scoring 34/48 and 25/48, respectively. A comprehensive analysis of scalability was prohibited by the widespread non-reporting of data, for example, those relating to cost-effectiveness. Of all sufficiently valid and reliable candidate tests identified, using our algorithm the 20-m shuttle run test was identified as the most scalable. We hope that the algorithm will prove useful in the examination of scalability in either new data relating to existing tests or in data pertaining to new tests. Springer International Publishing 2016-05-26 2016 /pmc/articles/PMC5097078/ /pubmed/27229897 http://dx.doi.org/10.1007/s40279-016-0553-6 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review Article
Domone, Sarah
Mann, Steven
Sandercock, Gavin
Wade, Matthew
Beedie, Chris
A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title_full A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title_fullStr A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title_full_unstemmed A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title_short A Method by Which to Assess the Scalability of Field-Based Fitness Tests of Cardiorespiratory Fitness Among Schoolchildren
title_sort method by which to assess the scalability of field-based fitness tests of cardiorespiratory fitness among schoolchildren
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097078/
https://www.ncbi.nlm.nih.gov/pubmed/27229897
http://dx.doi.org/10.1007/s40279-016-0553-6
work_keys_str_mv AT domonesarah amethodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT mannsteven amethodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT sandercockgavin amethodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT wadematthew amethodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT beediechris amethodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT domonesarah methodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT mannsteven methodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT sandercockgavin methodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT wadematthew methodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren
AT beediechris methodbywhichtoassessthescalabilityoffieldbasedfitnesstestsofcardiorespiratoryfitnessamongschoolchildren