Cargando…
Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues
The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (confo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097789/ https://www.ncbi.nlm.nih.gov/pubmed/27843284 http://dx.doi.org/10.1155/2016/8985690 |
_version_ | 1782465666091057152 |
---|---|
author | Sarikhani, Ali Motalebizadeh, Abbas Asiaei, Sasan Kamali Doost Azad, Babak |
author_facet | Sarikhani, Ali Motalebizadeh, Abbas Asiaei, Sasan Kamali Doost Azad, Babak |
author_sort | Sarikhani, Ali |
collection | PubMed |
description | The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal) surface. Moreover, insole thickness, heel's height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole), maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal) insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot. |
format | Online Article Text |
id | pubmed-5097789 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-50977892016-11-14 Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues Sarikhani, Ali Motalebizadeh, Abbas Asiaei, Sasan Kamali Doost Azad, Babak Appl Bionics Biomech Research Article The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal) surface. Moreover, insole thickness, heel's height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole), maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal) insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot. Hindawi Publishing Corporation 2016 2016-10-23 /pmc/articles/PMC5097789/ /pubmed/27843284 http://dx.doi.org/10.1155/2016/8985690 Text en Copyright © 2016 Ali Sarikhani et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Sarikhani, Ali Motalebizadeh, Abbas Asiaei, Sasan Kamali Doost Azad, Babak Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title | Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title_full | Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title_fullStr | Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title_full_unstemmed | Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title_short | Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues |
title_sort | studying maximum plantar stress per insole design using foot ct-scan images of hyperelastic soft tissues |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5097789/ https://www.ncbi.nlm.nih.gov/pubmed/27843284 http://dx.doi.org/10.1155/2016/8985690 |
work_keys_str_mv | AT sarikhaniali studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues AT motalebizadehabbas studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues AT asiaeisasan studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues AT kamalidoostazadbabak studyingmaximumplantarstressperinsoledesignusingfootctscanimagesofhyperelasticsofttissues |