The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices
Introduction. Manikin studies' data cannot accurately be extrapolated to real-life scenarios and inherent differences in design and materials of newer products may affect their clinical performance. Methods. Hence, we compared the AMBU® Aura-i™ and LMA Supreme™ in this randomized trial involvin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5099491/ https://www.ncbi.nlm.nih.gov/pubmed/27847515 http://dx.doi.org/10.1155/2016/4717061 |
_version_ | 1782465977511837696 |
---|---|
author | Yahaya, Zanahriah Teoh, Wendy H. Dintan, Nora A. Agrawal, Ravi |
author_facet | Yahaya, Zanahriah Teoh, Wendy H. Dintan, Nora A. Agrawal, Ravi |
author_sort | Yahaya, Zanahriah |
collection | PubMed |
description | Introduction. Manikin studies' data cannot accurately be extrapolated to real-life scenarios and inherent differences in design and materials of newer products may affect their clinical performance. Methods. Hence, we compared the AMBU® Aura-i™ and LMA Supreme™ in this randomized trial involving 100 ASA 1-2 unparalysed anaesthetised patients undergoing minor gynaecological surgery. Investigators had <20 Aura-i insertions. Primary outcome was time to achieve effective ventilation and secondarily insertion parameters, oropharyngeal leak pressures (OLP), fibreoptic positioning, and pharyngeal morbidity. The position of the Ambu Aura-i was evaluated with the Ascope; the fiberoptic view of the glottis was scored on a five-point scale. Results. 43 (86%) AMBU Aura-i and 44 (88%) LMA Supremes were successfully inserted on first attempt (p = 0.59), with similar ease (p = 0.79), and comparable times to first capnogram, mean (SD) 18.2 (6.0) versus 17.3 (6.4) sec, p = 0.9. The Aura-i needed significantly less volume of air to inflate its cuff to 60 cmH(2)O on the manometer, 17.7 (3.5) versus 23.1 (4.4) mL, p < 0.001. Both devices exhibited similar OLP, Aura-i versus LMA Supreme, mean (SD) 28.8 (7.1) versus 27.3 (5.3) cmH(2)O, p = 0.24. There was no difference in ease of insertion or adjustment manoeuvres to aid ventilation. 90% of patients had good positioning of Aura-i on fibreoptic check, yielding a view of the vocal cords and epiglottis. In 5 patients (10%), the vocal cords were not seen, but ventilatory function was unaffected. Conclusions. The Aura-i handled well in novices hands, with comparable times to insert and establish ventilation, similar leak pressures, and successful first attempt insertion rates compared to the LMA Supreme. |
format | Online Article Text |
id | pubmed-5099491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-50994912016-11-15 The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices Yahaya, Zanahriah Teoh, Wendy H. Dintan, Nora A. Agrawal, Ravi Anesthesiol Res Pract Clinical Study Introduction. Manikin studies' data cannot accurately be extrapolated to real-life scenarios and inherent differences in design and materials of newer products may affect their clinical performance. Methods. Hence, we compared the AMBU® Aura-i™ and LMA Supreme™ in this randomized trial involving 100 ASA 1-2 unparalysed anaesthetised patients undergoing minor gynaecological surgery. Investigators had <20 Aura-i insertions. Primary outcome was time to achieve effective ventilation and secondarily insertion parameters, oropharyngeal leak pressures (OLP), fibreoptic positioning, and pharyngeal morbidity. The position of the Ambu Aura-i was evaluated with the Ascope; the fiberoptic view of the glottis was scored on a five-point scale. Results. 43 (86%) AMBU Aura-i and 44 (88%) LMA Supremes were successfully inserted on first attempt (p = 0.59), with similar ease (p = 0.79), and comparable times to first capnogram, mean (SD) 18.2 (6.0) versus 17.3 (6.4) sec, p = 0.9. The Aura-i needed significantly less volume of air to inflate its cuff to 60 cmH(2)O on the manometer, 17.7 (3.5) versus 23.1 (4.4) mL, p < 0.001. Both devices exhibited similar OLP, Aura-i versus LMA Supreme, mean (SD) 28.8 (7.1) versus 27.3 (5.3) cmH(2)O, p = 0.24. There was no difference in ease of insertion or adjustment manoeuvres to aid ventilation. 90% of patients had good positioning of Aura-i on fibreoptic check, yielding a view of the vocal cords and epiglottis. In 5 patients (10%), the vocal cords were not seen, but ventilatory function was unaffected. Conclusions. The Aura-i handled well in novices hands, with comparable times to insert and establish ventilation, similar leak pressures, and successful first attempt insertion rates compared to the LMA Supreme. Hindawi Publishing Corporation 2016 2016-10-25 /pmc/articles/PMC5099491/ /pubmed/27847515 http://dx.doi.org/10.1155/2016/4717061 Text en Copyright © 2016 Zanahriah Yahaya et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Yahaya, Zanahriah Teoh, Wendy H. Dintan, Nora A. Agrawal, Ravi The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title | The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title_full | The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title_fullStr | The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title_full_unstemmed | The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title_short | The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices |
title_sort | ambu® aura-i™ laryngeal mask and lma supreme™: a randomized trial of clinical performance and fibreoptic positioning in unparalysed, anaesthetised patients by novices |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5099491/ https://www.ncbi.nlm.nih.gov/pubmed/27847515 http://dx.doi.org/10.1155/2016/4717061 |
work_keys_str_mv | AT yahayazanahriah theambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT teohwendyh theambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT dintannoraa theambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT agrawalravi theambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT yahayazanahriah ambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT teohwendyh ambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT dintannoraa ambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices AT agrawalravi ambuaurailaryngealmaskandlmasupremearandomizedtrialofclinicalperformanceandfibreopticpositioninginunparalysedanaesthetisedpatientsbynovices |