Cargando…

The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies

OBJECTIVES: To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. MATERIAL AND METHODS: An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywo...

Descripción completa

Detalles Bibliográficos
Autores principales: Maminskas, Julius, Puisys, Algirdas, Kuoppala, Ritva, Raustia, Aune, Juodzbalys, Gintaras
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Stilus Optimus 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5100644/
https://www.ncbi.nlm.nih.gov/pubmed/27833729
http://dx.doi.org/10.5037/jomr.2016.7304
_version_ 1782466183271809024
author Maminskas, Julius
Puisys, Algirdas
Kuoppala, Ritva
Raustia, Aune
Juodzbalys, Gintaras
author_facet Maminskas, Julius
Puisys, Algirdas
Kuoppala, Ritva
Raustia, Aune
Juodzbalys, Gintaras
author_sort Maminskas, Julius
collection PubMed
description OBJECTIVES: To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. MATERIAL AND METHODS: An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies of finite element analysis (FEA) were considered for inclusion that were written in English and revealed stress concentrations or strain at peri-implant bone level. RESULTS: There were included 20 FEA studies in total. Data were organized according to the following topics: bone layers, type of bone, osseointegration level, bone level, design of implant, diameter and length of implant, implant-abutment connection, type of supra-construction, loading axis, measurement units. The stress or strain at implant-bone contact was measured over all studies and numerical values estimated. Risks of overloading were accented as non-axial loading, misfits, cantilevers and the stability of peri-implant bone was related with the usage of platform switch connection of abutment. CONCLUSIONS: Peri-implant area could be affected by non-axial loading, cantilever prosthetic elements, crown/implant ratio, type of implant-abutment connection, misfits, properties of restoration materials and antagonistic tooth. The heterogeneity of finite element analysis studies limits systematization of data. Results of these studies are comparable with other findings of in vitro, in vivo, prospective and retrospective studies.
format Online
Article
Text
id pubmed-5100644
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Stilus Optimus
record_format MEDLINE/PubMed
spelling pubmed-51006442016-11-10 The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies Maminskas, Julius Puisys, Algirdas Kuoppala, Ritva Raustia, Aune Juodzbalys, Gintaras J Oral Maxillofac Res Literature Review OBJECTIVES: To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. MATERIAL AND METHODS: An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies of finite element analysis (FEA) were considered for inclusion that were written in English and revealed stress concentrations or strain at peri-implant bone level. RESULTS: There were included 20 FEA studies in total. Data were organized according to the following topics: bone layers, type of bone, osseointegration level, bone level, design of implant, diameter and length of implant, implant-abutment connection, type of supra-construction, loading axis, measurement units. The stress or strain at implant-bone contact was measured over all studies and numerical values estimated. Risks of overloading were accented as non-axial loading, misfits, cantilevers and the stability of peri-implant bone was related with the usage of platform switch connection of abutment. CONCLUSIONS: Peri-implant area could be affected by non-axial loading, cantilever prosthetic elements, crown/implant ratio, type of implant-abutment connection, misfits, properties of restoration materials and antagonistic tooth. The heterogeneity of finite element analysis studies limits systematization of data. Results of these studies are comparable with other findings of in vitro, in vivo, prospective and retrospective studies. Stilus Optimus 2016-09-09 /pmc/articles/PMC5100644/ /pubmed/27833729 http://dx.doi.org/10.5037/jomr.2016.7304 Text en Copyright © Maminskas J, Puisys A, Kuoppala R, Raustia A, Juodzbalys G. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 9 September 2016. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article, first published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 UnportedLicense (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work and is properly cited. The copyright, license information and link to the original publication on (http://www.ejomr.org) must be included.
spellingShingle Literature Review
Maminskas, Julius
Puisys, Algirdas
Kuoppala, Ritva
Raustia, Aune
Juodzbalys, Gintaras
The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title_full The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title_fullStr The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title_full_unstemmed The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title_short The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies
title_sort prosthetic influence and biomechanics on peri-implant strain: a systematic literature review of finite element studies
topic Literature Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5100644/
https://www.ncbi.nlm.nih.gov/pubmed/27833729
http://dx.doi.org/10.5037/jomr.2016.7304
work_keys_str_mv AT maminskasjulius theprostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT puisysalgirdas theprostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT kuoppalaritva theprostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT raustiaaune theprostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT juodzbalysgintaras theprostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT maminskasjulius prostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT puisysalgirdas prostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT kuoppalaritva prostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT raustiaaune prostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies
AT juodzbalysgintaras prostheticinfluenceandbiomechanicsonperiimplantstrainasystematicliteraturereviewoffiniteelementstudies