Cargando…
Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging
OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who u...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5102918/ https://www.ncbi.nlm.nih.gov/pubmed/27833406 http://dx.doi.org/10.3348/kjr.2016.17.6.903 |
_version_ | 1782466503548862464 |
---|---|
author | Yoo, Yeon Hwa Yoon, Choon-Sik Eun, Na Lae Hwang, Moon-jung Yoo, Hanna Peters, Robert D. Chung, Tae-Sub Lee, Young Han Suh, Jin-Suck Kim, Sungjun |
author_facet | Yoo, Yeon Hwa Yoon, Choon-Sik Eun, Na Lae Hwang, Moon-jung Yoo, Hanna Peters, Robert D. Chung, Tae-Sub Lee, Young Han Suh, Jin-Suck Kim, Sungjun |
author_sort | Yoo, Yeon Hwa |
collection | PubMed |
description | OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1–2 through L5–S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs. |
format | Online Article Text |
id | pubmed-5102918 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-51029182016-11-10 Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging Yoo, Yeon Hwa Yoon, Choon-Sik Eun, Na Lae Hwang, Moon-jung Yoo, Hanna Peters, Robert D. Chung, Tae-Sub Lee, Young Han Suh, Jin-Suck Kim, Sungjun Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1–2 through L5–S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs. The Korean Society of Radiology 2016 2016-10-31 /pmc/articles/PMC5102918/ /pubmed/27833406 http://dx.doi.org/10.3348/kjr.2016.17.6.903 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Musculoskeletal Imaging Yoo, Yeon Hwa Yoon, Choon-Sik Eun, Na Lae Hwang, Moon-jung Yoo, Hanna Peters, Robert D. Chung, Tae-Sub Lee, Young Han Suh, Jin-Suck Kim, Sungjun Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title | Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title_full | Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title_fullStr | Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title_full_unstemmed | Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title_short | Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging |
title_sort | interobserver and test-retest reproducibility of t1ρ and t2 measurements of lumbar intervertebral discs by 3t magnetic resonance imaging |
topic | Musculoskeletal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5102918/ https://www.ncbi.nlm.nih.gov/pubmed/27833406 http://dx.doi.org/10.3348/kjr.2016.17.6.903 |
work_keys_str_mv | AT yooyeonhwa interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT yoonchoonsik interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT eunnalae interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT hwangmoonjung interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT yoohanna interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT petersrobertd interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT chungtaesub interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT leeyounghan interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT suhjinsuck interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging AT kimsungjun interobserverandtestretestreproducibilityoft1randt2measurementsoflumbarintervertebraldiscsby3tmagneticresonanceimaging |